info WAT200606 - Extraction Manifold,20 pos, 13x75 mm tubes
Part Number: WAT200606
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info WAT200609 - Extraction Manifold, 20pos, 16x100mm tubes
Part Number: WAT200609
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info

725000142 - Diverter Valve (standard)

Part Number: 725000142

The standard Diverter Valve (three-way valve) diverts the flow of solvent to a waste vessel as the dropper assembly moves between collection vessel positions.

725000142 - Diverter Valve (standard)
Part Number: 725000142
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Systems Components
Products Waters Fraction Collector II
Waters Fraction Collector III
Replacement Schedule As Needed

info

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003581

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003581
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052669

The Waters® Performance Maintenance Kit for the 717 Autosampler contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance. The Waters® Performance Maintenance Kit includes the following parts: one seal pack replacement kit, one syringe, one filter insert assembly, one 2.3mm x 11.5mm filter, and two 2mm x 7mm filters.

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052669
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Injectors
Replacement Schedule Annually

info

WAT035708 - Polyisoprene Standards Kit

Part Number: WAT035708

A unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. Polyisoprene Standard Kit 10 Vials, 0.5g in each vial containing the following moleculare weight standards: 1000, 3000, 10000, 30000, 70000, 100000, 300000, 500000, 1000000, 3000000

WAT035708 - Polyisoprene Standards Kit
Part Number: WAT035708
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003964

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003964
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

700001321 - Needle w/Housing and Needle Drive Motor

Part Number: 700001321

The Needle w/Housing and Needle Drive Motor is an improvement for the 2790 and standard for the 2795 Separations Module. The new needle with housing assembly includes a high tension stripper spring. The stronger spring allows the needle to shed polyethylene cap mats at temperatures as low as 4 degrees in the sample compartment. The higher force spring requires a higher torque motor to prevent stalling during initialization.

700001321 - Needle w/Housing and Needle Drive Motor
Part Number: 700001321
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

725000417 - Vacuum Pump 110/115 V 60H

Part Number: 725000417

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

725000417 - Vacuum Pump 110/115 V 60H
Part Number: 725000417
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

205000730 - Active Preheater

Part Number: 205000730

ACQUITY Active Preheater (APH) SS 12.5 inches long

205000730 - Active Preheater
Part Number: 205000730
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY H-Class Column Heater-Active
Replacement Schedule As Needed

info

186005291 - XSelect CSH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005291

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005291 - XSelect CSH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005291
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005401

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005401
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004504

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004504
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006732

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006732
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006738

XSelect HSS C18 is a general purpose, high performance C18 chemistry with exceptional retention and peak shape for all compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006738
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

201000281 - ACQUITY PDA/TUV 2489/2998 PERFORMANCE MAINTENANCE KIT

Part Number: 201000281

The Waters® Performance Maintenance Kit for the ACQUITY UPLC TUV/PDA contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. It is used in ACQUITY UPLC PDA Detectors, ACQUITY eLambda PDA Detector, ACQUITY UPLC TUV Detectors, 2489 Dual Wavelength UV Detector and the 2998 PDA Detector. The old part number was 201000186. The Waters® Performance Maintenance Kit includes the following parts: PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first.

201000281 - ACQUITY PDA/TUV 2489/2998 PERFORMANCE MAINTENANCE KIT
Part Number: 201000281
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Detectors
Products 2489 UV/Visible Detector
2998 Photodiode Array Detector
ACQUITY UPLC PDA Detector
ACQUITY UPLC TUV Detector
ACQUITY UPLC eLAmbda PDA Detector
Replacement Schedule Annually

info

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004500

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004500
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186001470 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001470

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186001470 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001470
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

700005515 - Patrol UPLC Absorbance Start-Up Solution

Part Number: 700005515

Standards kit appropriate for performance verification of a UV Patrol System Contains:3 Ampules (10ml each of standard solutions containing): Solution 1 0.1000 mg/mL Caffeine Solution 2 4.00 ?g/mL each of 2-Acetylfuran, Acetanilide, Acetophenone, Propiophenone, Butylparaben, Benzophenone and Valerophenone Solution 3 4.000 mg/mL Caffeine

700005515 - Patrol UPLC Absorbance Start-Up Solution
Part Number: 700005515
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006943

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006943
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186004453 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186004453

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004453 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186004453
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186004740 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186004740

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004740 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186004740
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007116 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007116

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007116 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007116
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700005162 - i2 Valve

Part Number: 700005162

ACQUITY H-Class QSM I2V Assembly

700005162 - i2 Valve
Part Number: 700005162
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category ACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
Replacement Schedule As Needed

info

186005984 - ACQUITY UPLC HSS Cyano (CN) Column, 100Å, 1.8 µm, 1 mm X 150 mm, 1/pkg

Part Number: 186005984

ACQUITY UPLC HSS CN chemistry is an ultra-performance general purpose propyl cyano bonded phase that provides superior peak shape for bases, increased retention, and extremely long column lifetimes at low pH. ACQUITY HSS CN columns are fully scalable and transferable to HPLC separations.

186005984 - ACQUITY UPLC HSS Cyano (CN) Column, 100Å, 1.8 µm, 1 mm X 150 mm, 1/pkg
Part Number: 186005984
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 5
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

186007378 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007378

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007378 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007378
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186006727 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006727

XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006727 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006727
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11