Product Listing:  700005472 - XEVO TQ-S Qualification Standards KIT   to   186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg

Sorted by Popularity
  Product    
info

700005472 - XEVO TQ-S Qualification Standards KIT

Part Number: 700005472

Mass Spectrometry (Xevo TQ-S) standards kit for system assessment. 11 Components: 1. 1 x 25mL Xevo TQ-S Tuning Solution X100: Acetominophen (4-Acetamidophenol) 2 ng/ul Caffeine, 2 ng/ul, Sulfadimethoxine, 1 ng/ul, Verapamil, 500 pg/ul, Chloramphenicol, 500 pg/ul, 17-A-Hydroxyprogesterone, 50 ng/ul, 90% MeOH:10% Water Flame Sealed Ampule 2. 1 x 30mL Set-up solution Xevo TQ-S: PPG1000 250 pg/ul, Triacetyl-B-cyclodextrin 500 pg/ul, Verapmil 10 pg/ul, Leucine Enkaphalin 100 pg/ul, Ammonium Acetate 0.31 mg/ml, Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 3. 1 x 30mL Intellistart Resolution Solution X20: Sodium Iodide 2 µg/ul Cesium Iodide 50 ng/ul, Methyl Sulfate Sodium Salt 20 ng/µl, in IPA/Water (1:1 V/V) Clear Nalgene Bottle 4. 1 x 30mLCalibration Solution: Ortho-Phosphoric Acid 0.1% Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 5. 1 x 10 mg Ion Sabre APCI Pos Sensitivity: 17-alphahydroxyprogesterone 10 mg Solid 4 ml Amber Screw Top Vial 6. 1 x 50 mg ESI Negative Sensitivity: Chloramphenicol Solid 50 mg 8 ml Amber Screw Top Vial 7. 1 x 5mg ESI Positive Sensitivity: Reserpine solid 5 mg 4 ml Amber Screw Top Vial 8. 1 x 5mg CarryOver Test QWB: Sulfadimethoxine Solid 5mg 4 ml Amber Screw Top Vial 9. 1 x 0.1mg* [Glu1]-Fibrinopeptide B ScanWave Optimization: 0.1 mg ±0.01 mg 4 mL Amber Screw top Vial 10. 1 x 3mL Mobile phase additive: Aqueous Ammonia Specific Gravity - 0.88 to 0.89 (~30% w/w ammonia) Flame sealed ampule 11. 2 x 1mLMobile phase Additive: Formic Acid 98-100% Purity Flame sealed ampule 1 X 715002796 Solution Prep – Xevo TQ-s Document Certificate of Analysis

700005472 - XEVO TQ-S Qualification Standards KIT
Part Number: 700005472
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT

Part Number: WAT052586

The Waters® Performance Maintenance Kit for the 996/2996/ACQUITY 2996 PDA Detector contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts:a PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first, and an air filter.

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT
Part Number: WAT052586
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Capillary LC
Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
ACQUITY UPLC 2996 PDA Detector
CapLC 2996
Replacement Schedule Annually

info

700004867 - Kit, Cartridge Check Valve, 2555Q

Part Number: 700004867

This spare part is a Waters Quality part.

700004867 - Kit, Cartridge Check Valve, 2555Q
Part Number: 700004867
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 2555 Quaternary Gradient Module
Replacement Schedule As Needed

info

WAT270872 - Plunger Seal-Wash Option Kit

Part Number: WAT270872

The Plunger Seal Wash Option Kit includes: two Seal Wash Plunger Seals, four Seal Wash Tube Seals, one Solenoid Pump , two 1/8in.Tefzel Ferrules, two 1/8in. Peek Compression Screws, Tubing, .062 Id x 120 OD 175in. , one Diffuser Assembly. one Shrink Marker, and two Seal Wash Face Seals.

WAT270872 - Plunger Seal-Wash Option Kit
Part Number: WAT270872
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

WAT060042 - Drawoff Valve

Part Number: WAT060042

The Drawoff Valve allows one to draw eluent from a solvent reservoir to help with priming or purging the pump.

WAT060042 - Drawoff Valve
Part Number: WAT060042
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump

info

700004155 - Two Cuvette Kit (empty)

Part Number: 700004155

Cuvettes – 2 Each Materials: Quartz, 190 through 800nm Cuvettes to be from same lot of Quartz.

700004155 - Two Cuvette Kit (empty)
Part Number: 700004155
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Product Type Standard
Storage Room temp

info

WAT034220 - Shodex DS-613 Column, 6 µm, 6 x 150 mm

Part Number: WAT034220

Polymeric reverse phase columns for applications requiring broad pH range

WAT034220 - Shodex DS-613 Column, 6 µm, 6 x 150 mm
Part Number: WAT034220
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Shodex
Format Column
ID 6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Pore Size 1000Å
Units in Package 1/pkg
pH Range 2 - 12

info

WAT034221 - Shodex DE-613 Column, 6 µm, 6 x 150 mm

Part Number: WAT034221

Polymeric reverse phase columns for applications requiring broad pH range

WAT034221 - Shodex DE-613 Column, 6 µm, 6 x 150 mm
Part Number: WAT034221
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Shodex
Format Column
ID 6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Pore Size 1000Å
Solvent Water
Units in Package 1/pkg
pH Range 2 - 12

info

WAT051518 - Gradient Mixer, Single Stage

Part Number: WAT051518

The Single Stage Gradient Mixer insures complete mixing of solvents in a gradient system. It is a flow-through device that responds rapidly to solvent composition changes due to its low volume.

WAT051518 - Gradient Mixer, Single Stage
Part Number: WAT051518
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 510 HPLC Pump
PrepLC 2000
PrepLC 4000
Replacement Schedule No

info

700000356 - PerformancePlus™ Long-life Detector Lamp

Part Number: 700000356

Waters PerformancePlus™ Long-life lamps ensure reliable performance with a lower cost of ownership through less downtime and a strict adherence to regulatory guidelines. Waters PerformancePlus™ Long-life lamps are easy to install, ensures that the lamp energy is maintained at all wavelengths, and have a warranty of 2000 hours or 1 year, whichever comes first. The original part number was WAT080678 and has been changed to 700000356.

700000356 - PerformancePlus™ Long-life Detector Lamp
Part Number: 700000356
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Lamps
Product Category Detectors
Systems
Products 486 Tunable UV/Visible Absorbance Detector
LC Module 1
Replacement Schedule As Needed

info

186007122 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186007122

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007122 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186007122
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

725000142 - Diverter Valve (standard)

Part Number: 725000142

The standard Diverter Valve (three-way valve) diverts the flow of solvent to a waste vessel as the dropper assembly moves between collection vessel positions.

725000142 - Diverter Valve (standard)
Part Number: 725000142
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Systems Components
Products Waters Fraction Collector II
Waters Fraction Collector III
Replacement Schedule As Needed

info

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006938

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006938
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052669

The Waters® Performance Maintenance Kit for the 717 Autosampler contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance. The Waters® Performance Maintenance Kit includes the following parts: one seal pack replacement kit, one syringe, one filter insert assembly, one 2.3mm x 11.5mm filter, and two 2mm x 7mm filters.

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052669
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Injectors
Replacement Schedule Annually

info

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003581

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003581
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT035708 - Polyisoprene Standards Kit

Part Number: WAT035708

A unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. Polyisoprene Standard Kit 10 Vials, 0.5g in each vial containing the following moleculare weight standards: 1000, 3000, 10000, 30000, 70000, 100000, 300000, 500000, 1000000, 3000000

WAT035708 - Polyisoprene Standards Kit
Part Number: WAT035708
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003964

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003964
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003965

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003965
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004454

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004454
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

725000417 - Vacuum Pump 110/115 V 60H

Part Number: 725000417

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

725000417 - Vacuum Pump 110/115 V 60H
Part Number: 725000417
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

info

201000144 - LOCK SPRAY PERFORMANCE MAINTENANCE KIT

Part Number: 201000144

The Waters® Performance Maintenance Kit for the optional Lockspray source found on earlier Mass Spectometers such as the Q-Tof I, Q-Tof II, Q-Tof Ulima, Q-Tof API-US and the Q-Tof micro contains all the Waters Quality Parts® necessary to keep you operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: probe tip, o-rings, tubing and other components to re-build the lockspray probe.

201000144 - LOCK SPRAY PERFORMANCE MAINTENANCE KIT
Part Number: 201000144
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Mass Spectrometer
Q-Tof II Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Q-Tof micro Mass Spectrometer
Replacement Schedule Annually

info

186003041 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186003041

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003041 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186003041
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005401

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005401
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005291 - XSelect CSH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005291

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005291 - XSelect CSH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005291
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006738

XSelect HSS C18 is a general purpose, high performance C18 chemistry with exceptional retention and peak shape for all compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006738
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006732

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006732
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004504

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004504
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

205000730 - Active Preheater

Part Number: 205000730

ACQUITY Active Preheater (APH) SS 12.5 inches long

205000730 - Active Preheater
Part Number: 205000730
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY H-Class Column Heater-Active
Replacement Schedule As Needed

info

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004500

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004500
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12