Product Listing:  205016040 - nanoACQUITY UPLC Flex Cart   to   201000131 - 2475 PERFORMANCE MAINTENANCE KIT

Sorted by Popularity
  Product    
info

205016040 - nanoACQUITY UPLC Flex Cart

Part Number: 205016040

The wheeled cart is a complete system platform that facilitates convenient installation of the nanoACQUITY UPLC. It is recommended that a Waters Field Service Engineer install the nanoACQUITY system onto the Flex Cart.

205016040 - nanoACQUITY UPLC Flex Cart
Part Number: 205016040
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
High Pressure nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

700001430 - Tubing Kit (2767/2747)

Part Number: 700001430

The 2767/2747 Tubing Kit contains the following tubing: (1) wash 1 inlet to select Valve (T2), (1) wash2 inlet to select Valve (T1), (1) select valve to MW inlet (T4), (1) MW outlet to 3-way (T5), (1) 3-way to wash path valve (T22), (1) wash path valve to vent (T6), (1) wash path valve to probe (T7), (1) probe tubing (T8), (1) diverter inlet 0.020in ID (T9), (1) diverter outlet tube (T10), (1) diverter dispense tube (T23), (2) tubing assembly: inject valve to wash (T11), (1) probe-tube sealer (T26), (1) diverter inlet 0.010in ID (T27), and (1) diverter inlet 0.040in ID (T28).

700001430 - Tubing Kit (2767/2747)
Part Number: 700001430
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Injectors
Products 2767/2747 Sample Manager
Replacement Schedule As Needed

info

186000863 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 250 mm, 3/pkg

Part Number: 186000863

This kit consists of three XTerra RP 18 columns packed with three different batches of sorbent.

186000863 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 250 mm, 3/pkg
Part Number: 186000863
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12

info

700002660 - Vent Valve/Trap Valve Cartridge

Part Number: 700002660

This spare part is a Waters Quality part.

700002660 - Vent Valve/Trap Valve Cartridge
Part Number: 700002660
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category ACQUITY
nanoACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
ACQUITY UPLC Binary Solvent Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule As Needed

info

700004588 - LockSpray Ref Probe Assy

Part Number: 700004588

This spare part is a Waters Quality part.

700004588 - LockSpray Ref Probe Assy
Part Number: 700004588
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

186003769 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186003769

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003769 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186003769
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186005465

The reproducibility of a chromatographic column has a critical impact on the long-term reliability and robustness of an analytical method, and its reproducibility lies completely outside the user's control. With exceptional batch-to-batch and column-to-column reproducibility, Waters well-established particle and column manufacturing process control provides confidence in the long-term reliability of your analytical method. XBridge BEH300 C4, 3.5um Method Validation Kit includes three batches of chromatographic media [derived from different base particles] to judge the quality, reliability, and consistency of your chromatographic method. Each batch of selected XBridge BEH300 C18, 3.5um chemistry is specifically QC tested with a mixture of carefully selected protein standards to help ensure consistent performance.

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186005465
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 3/pkg
pH Range 1 - 10

info

700004606 - Bottle Waste Trap Assembly

Part Number: 700004606

This spare part is a Waters Quality part.

700004606 - Bottle Waste Trap Assembly
Part Number: 700004606
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2-S
SPECVALUE134881948
Xevo G2-S
Xevo G2-S QTof
Xevo Q-Tof Mass Spec
Xevo TQ-S MS
Xevo™ TQ MS
Replacement Schedule As Needed

info

186006414 - XSelect HSS C18 Method Validation Kit, 100Å, 5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186006414

The HSS C18 packing is the most stable commercially available bonded phase and does not suffer from peak shape issues that plague older stationary phases that rely upon steric protection (and lack of endcapping) to produce stability at low pH. The HSS C18 HPLC columns are fully scalable and are completely transferable to UPLC separations.

186006414 - XSelect HSS C18 Method Validation Kit, 100Å, 5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186006414
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

WAT047491 - Flow Cell Replacement Kit (16ul)

Part Number: WAT047491

The 16µL Flow Cell Replacement kit contains the following items: (1) 16µL flow cell, (1) gasket (upper), and (1) gasket (lower), 4 wells.

WAT047491 - Flow Cell Replacement Kit (16ul)
Part Number: WAT047491
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 474 Scanning Fluorescence Detector

info

186001757 - HSPgel Column, RT MB-L, 3 µm, 6 mm X 150 mm, 100 - 10K, THF , 1/pkg

Part Number: 186001757

The new HSPgel columns are specifically designed for high speed GPC analysis. They offer fast, accurate and precise molecular weight polymer determinations as well as increased sample throughput and greatly reduced solvent consumption and disposal costs. With the advent of today's higher performance solvent management systems, many polymers can now be analyzed accurately and reproducibly utilizing lower volume columns. This results in total analysis times of 7 minutes or less, thereby increasing sample throughput up to 6x while decreasing solvent usage from 35-50 mL to 5 mL or less per run.

186001757 - HSPgel Column, RT MB-L, 3 µm, 6 mm X 150 mm, 100 - 10K, THF , 1/pkg
Part Number: 186001757
Brand: HSPgel
HSPgel™ GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 6 mm
Length (mm) 150 mm
Mode SEC/GPC
Molecular Weight Range 100 - 10K
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Polymer
Pore Size RT MB-L
Solvent THF
Units in Package 1/pkg

info

186006234 - XSelect CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186006234

This method validation kit consists of three batches of XSelect CSH C18 columns packed with three different batches of sorbent

186006234 - XSelect CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 186006234
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

201000252 - Xevo TQD / SQD 2 (Rotary Pump) Performance Maintenance Kit

Part Number: 201000252

This Waters® Performance Maintenance Kit is a hardware PM Kit only. There is no chemical kit included. The part number for the PM Kit with chemistry is part number 176002780.

201000252 - Xevo TQD / SQD 2 (Rotary Pump) Performance Maintenance Kit
Part Number: 201000252
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products SQ Detector 2
Xevo TQD
Replacement Schedule Annually

info

186000195 - Symmetry C18 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186000195

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

186000195 - Symmetry C18 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186000195
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Symmetry300 Columns
% Carbon Load 8.5
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 300Å
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

700001556 - Rheodyne RV700-136

Part Number: 700001556

Located at the top of the CFO, The RV700-136 is a stainless steel 2-position, 6-port motorized valve. This valve is used to switch between analytical and preparative modes.

700001556 - Rheodyne RV700-136
Part Number: 700001556
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Pumps
Products Column/Fluidics Organizer
System Fluidics Organizer
Replacement Schedule No

info

176002565 - XBridge BEH Shield RP18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176002565

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

176002565 - XBridge BEH Shield RP18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176002565
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186002161 - BioSuite SEC Column, 125Å, 4 µm, 4.6 mm X 300 mm, 5K - 150K, 1/pkg

Part Number: 186002161

BioSuite SEC Columns are available in 4.6 mm, 7.5 mm, and 7.8 mm i.d. analytical and 21.5 mm i.d. preparative and guard columns.

186002161 - BioSuite SEC Column, 125Å, 4 µm, 4.6 mm X 300 mm, 5K - 150K, 1/pkg
Part Number: 186002161
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry SEC
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 5K - 150K
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 125Å
System HPLC
USP Classification L59
Units in Package 1/pkg
pH Range 2.5 - 7.5

info

201000114 - 1525 PERFORMANCE MAINTENANCE KIT

Part Number: 201000114

The Waters® Performance Maintenance Kit for the 1525 binary pump contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Four Clear-100 Seals, four sapphire plungers, eight PerformancePLUS cartridges, one reference valve rebuild kit, and two solvent filters.

201000114 - 1525 PERFORMANCE MAINTENANCE KIT
Part Number: 201000114
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products 1525 HPLC Pump
Replacement Schedule Annually

info

700002789 - 2695 Phase II Injector Assembly

Part Number: 700002789

The new 2695 Injector Assembly includes only the new injector.To upgrade a 2695 to the new injector assembly, you must order both the new injector (part number 700002789) and the Upgrade Kit (part Number 700002790).

700002789 - 2695 Phase II Injector Assembly
Part Number: 700002789
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

700002765 - ACQUITY Everflow Injector Pod/Cartridge

Part Number: 700002765

ACQUITY SM Everflow Injector Pod/Cartridge

700002765 - ACQUITY Everflow Injector Pod/Cartridge
Part Number: 700002765
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

201000107 - 2790/2795 PERFORMANCE MAINTENANCE KIT

Part Number: 201000107

The Waters® Performance Maintenance Kit for the 2790/2795 contains all the Waters Quality Parts® necessary to keep your 2790/2795 operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: one injection port seat, one injection port washer seal, one needle, one 500µL syringe, one filter insert assembly, two check valve cartidges, two plungers, two seals, four face seals, four seal wash tubes, seven solvent filters, one lithium battery, two seal wash face seals, two plunger wash seals, and one 2790 injector valve PM Kit.

201000107 - 2790/2795 PERFORMANCE MAINTENANCE KIT
Part Number: 201000107
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule Annually

info

WAT073571 - Rheodyne, Prep Injector Valve

Part Number: WAT073571

This spare part is part of the Preparative Chromatography Rack for the 25X5 series of pumps.

WAT073571 - Rheodyne, Prep Injector Valve
Part Number: WAT073571
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Pumps
Products 2545 Quaternary Gradient Pump
FlexInject Manual Dual Injector Module
Rheodyne Injector
Replacement Schedule As Needed

info

201000196 - 2707 AUTOSAMPLER PERFORMANCE MAINTENANCE KIT

Part Number: 201000196

The Waters® Performance Maintenance Kit for the 2707 Autosampler contains all the Waters Quality Parts® necessary to keep your 2707 Autosampler operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: air needle (62mm), standard needle assembly, wash station with screws, a syringe valve, buffer tubing (1000µL), rotor seal and 500µL syringe.

201000196 - 2707 AUTOSAMPLER PERFORMANCE MAINTENANCE KIT
Part Number: 201000196
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Injectors
Products 2707 Autosampler
Replacement Schedule Annually

info

WAT033446 - Rheodyne 9125 PEEK Injector

Part Number: WAT033446

The Rheodyne 9125 PEEK Injector is non-metallic with a Tefzel rotor and a stator made of PEEK. The maximum operating pressure for this injector is 5000psi.

WAT033446 - Rheodyne 9125 PEEK Injector
Part Number: WAT033446
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Pumps
Products 626 LC System
Replacement Schedule No

info

WAT081157 - Inert Taper Slit Flow Cell

Part Number: WAT081157

The Waters®TaperSlit™ Flow Cell design used in the 2487 detector renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Inert TaperSlit™ Flow Cell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The Inert Cell has a 10mm path length and a cell volume of 10µL.

WAT081157 - Inert Taper Slit Flow Cell
Part Number: WAT081157
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

WAT081158 - Semi-Prep Taper Slit Flow Cell

Part Number: WAT081158

The Waters®TaperSlit™ Flow Cell design used in the 2487 detector renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Semi-Prep TaperSlit™ Flow Cell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The Semi-Prep Cell has a 3mm path length and a cell volume of 2.6µL.

WAT081158 - Semi-Prep Taper Slit Flow Cell
Part Number: WAT081158
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

WAT011787 - Protein-Pak 300SW Glass Column, 10 µm, 8 x 300 mm

Part Number: WAT011787

7 µm diol-bonded silica-based gel filtration material.

WAT011787 - Protein-Pak 300SW Glass Column, 10 µm, 8 x 300 mm
Part Number: WAT011787
Brand: Protein-Pak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Protein-Pak Columns
Application Protein
Chemistry SEC
Endfitting Type Parker-style
Format AP Glass Column
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 300Å
Solvent Water
USP Classification L20
Units in Package 1/pkg
pH Range 2 - 8

info

WAT270944 - 2690/95 PERFORMANCE MAINTENANCE KIT

Part Number: WAT270944

The Waters® Performance Maintenance Kit for the 2690 Separations Module contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: one diffuser assembly, one filter insert assembly, four stainless steel solvent filters, four face seals, 2 fluoroloy seals, one syringe, one compression screw, one sealwash injector tube, one needlewash frit, five sealwash tubes, two seals, one spacer, two plungers, one teflon washer, two plunger seal wash, one lithium battery, one needle wash filter, one filter retainer, thin walled teflon tubing, two check valve cartridge assemblies, powder-free gloves, one injector needle and one injector needle ferrule.

WAT270944 - 2690/95 PERFORMANCE MAINTENANCE KIT
Part Number: WAT270944
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule Annually

info

WAT025248 - Rheodyne 7725I Manual Injector

Part Number: WAT025248

The Rheodyne 7725I Manual Injector is a stand-alone injector that can be used on the 1525 Micro Binary HPLC Pump.

WAT025248 - Rheodyne 7725I Manual Injector
Part Number: WAT025248
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Pumps
Products 1525 Micro HPLC Pump
Rheodyne Injector
Replacement Schedule As Needed

info

201000131 - 2475 PERFORMANCE MAINTENANCE KIT

Part Number: 201000131

The Waters® Performance Maintenance Kit for the 2475 Multi-Wavelength Fluorescence Detector contains all the Waters Quality Parts® necessary to keep your 2475 detector operating at peak performance. The kit also contains a detailed maintenance protocol, including calibration and diagnostic tests to ensure proper installation and function.The xenon lamp has a warranty for a lifetime of 2000 hours or 1 year, whichever comes first.

201000131 - 2475 PERFORMANCE MAINTENANCE KIT
Part Number: 201000131
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Detectors
Products 2475 Multi-channel Fluorescence Detector
Replacement Schedule Annually