Product Listing:  WAT011604 - Polystyrene Standard 43,000   to   186003663 - XBridge Peptide BEH C18 Column, 300Å, 10 µm, 4.6 mm X 50 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

WAT011604 - Polystyrene Standard 43,000

Part Number: WAT011604

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 42,000 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011604 - Polystyrene Standard 43,000
Part Number: WAT011604
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011624 - Polystyrene Standard 5,200,000

Part Number: WAT011624

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 5,200,000 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011624 - Polystyrene Standard 5,200,000
Part Number: WAT011624
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186006372 - UPC2 Standard Mix

Part Number: 186006372

2 mg/ml each of 3-benzoylpyridine, Cortisone. 4-nitroaniline, 4,4’-biphenol in methanol solution

186006372 - UPC2 Standard Mix
Part Number: 186006372
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System SFC

info

WAT011614 - Polystyrene Standard 780,000

Part Number: WAT011614

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 780,000 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011614 - Polystyrene Standard 780,000
Part Number: WAT011614
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011592 - Polystyrene Standard 530

Part Number: WAT011592

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 530 Da Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011592 - Polystyrene Standard 530
Part Number: WAT011592
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011598 - Polystyrene Standard 6,400

Part Number: WAT011598

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 6,400 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011598 - Polystyrene Standard 6,400
Part Number: WAT011598
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186006521 - UPC2 Standard Ibuprofen

Part Number: 186006521

Individual ibuprofen standard formulated for use with SFC. 1.0 mg/mL ibuprofen in 2-propanol, 2mL

186006521 - UPC2 Standard Ibuprofen
Part Number: 186006521
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011626 - Polystyrene Standard 6,200,000

Part Number: WAT011626

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 6,200,000 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011626 - Polystyrene Standard 6,200,000
Part Number: WAT011626
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011612 - Polystyrene Standard 430,000

Part Number: WAT011612

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polystyrene at 430,000 Da. Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011612 - Polystyrene Standard 430,000
Part Number: WAT011612
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186006522 - UPC2 Standard Ketoprofen

Part Number: 186006522

Individual ketoprofen standard formulated for use with SFC. 1.0 mg/mL ketoprofen in 2-propanol, 2mL

186006522 - UPC2 Standard Ketoprofen
Part Number: 186006522
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT011590 - Polystyrene Standard 400

Part Number: WAT011590

An individual GPC standard (Gel Permeation Chromatography standards) for molecular weight determination. Polysytrene Standard at 4000 Da Polystyrene calibration standards for use in characterizing or confirming your chemical analysis. This high-quality, proven standards provide confidence in your results.

WAT011590 - Polystyrene Standard 400
Part Number: WAT011590
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector Mass Spec
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186006523 - UPC2 Standard Flavone

Part Number: 186006523

Individual flavone standard formulated for use with SFC. 1.0 mg/mL flavone in 2-propanol, 2mL

186006523 - UPC2 Standard Flavone
Part Number: 186006523
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186006524 - UPC2 Standard Flurbiprofen

Part Number: 186006524

Individual flurbiprofen standard formulated for use with SFC. 1.0 mg/mL flurbiprofen in 2-propanol, 2mL

186006524 - UPC2 Standard Flurbiprofen
Part Number: 186006524
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT022365 - PREPLC 40MM EXTEION KIT

Part Number: WAT022365
WAT022365 - PREPLC 40MM EXTEION KIT
Part Number: WAT022365
Products > Chromatography Consumables & Columns > Accessories > Radial Compression

info

176005672IVD - MassTrak C18 OSM, 10 μm, 1x10 mm, 96/pk

Part Number: 176005672IVD

MassTrak C18 Online Solid-Phase Extraction (SPE) Cartridges are intended for in vitro diagnostic testing to analyze many diagnostic compounds, including diagnostic indicators and therapeutically monitored compounds. These cartridges are designed for single use with the ACQUITY UPLC Online SPE Manger, which is a component of the MassTrak Online SPE Analyzer. The MassTrak C18 sorbent uses Waters proprietary Ethylene Bridged Hybrid (BEH) Technology to provide particles with high mechanical strength, excellent peak shape, high efficiency, and excellent pH stability for acidic and basic extraction solvents. MassTrak C18 Online SPE Cartridges can withstand pressures up to 15,000 psi (1,000 bar) during the SPE elution stage and are compatible with solvents in the pH 1-12 range. Each tray contains 96 cartridges.

176005672IVD - MassTrak C18 OSM, 10 μm, 1x10 mm, 96/pk
Part Number: 176005672IVD
Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Units In Package 96/pkg

info

186006345 - Oasis Sorbent Selection Flangeless Cartridge Kit, 30 mg/1 cc cartridge

Part Number: 186006345

The Oasis sorbent selection flangeless cartridge kit is specifically designed for rapid development of SPE methods for LC/MS analysis. The kit contains 40 cartridges — 10 each of the appropriate Oasis mixed-mode, ion-exchange chemistry: MAX (strong anion exchanger), WAX (weak anion exchanger), MCX (strong cation exchanger), and WCX (weak cation exchanger). Sample preparation method development can be quickly and easily achieved with the use of only two SPE protocols using these chemistries.

186006345 - Oasis Sorbent Selection Flangeless Cartridge Kit, 30 mg/1 cc cartridge
Part Number: 186006345
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry Method Development
Format/Type Sorbent Selection Kit
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 30 mg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

WAT023605 - Sep-Pak Diol 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk

Part Number: WAT023605

Silica-based polar bonded phase with neutral character; can be used as an alternative to silica in normal-phase applications, where the acidic character of silica is undesirable or as very weakly interacting phase in aqueous applications; applications include antibiotics from cosmetics; isolation of proteins or peptides by hydrophobic interaction chromatography.

WAT023605 - Sep-Pak Diol 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk
Part Number: WAT023605
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry Diol
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Normal-phase
Reversed-phase
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186003463 - Oasis Method Development 1 cc Sorbent Selection Kit, 30 mg Sorbent per Cartridge, 30 µm Particle Size, 40/pk

Part Number: 186003463

The Oasis sorbent selection cartridge kit is specifically designed for rapid development of SPE methods for LC/MS analysis. The kit contains 40 cartridges — 10 each of the appropriate Oasis mixed-mode, ion-exchange chemistry: MAX (strong anion exchanger), WAX (weak anion exchanger), MCX (strong cation exchanger), and WCX (weak cation exchanger). Sample preparation method development can be quickly and easily achieved with the use of only two SPE protocols using these chemistries.

186003463 - Oasis Method Development 1 cc Sorbent Selection Kit, 30 mg Sorbent per Cartridge, 30 µm Particle Size, 40/pk
Part Number: 186003463
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry Method Development
Format/Type Sorbent Selection Kit
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 30 mg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info 186006967 - Black Aluminum, Crimp Cap and PTFE/silicone Septum, 100/pkg
Part Number: 186006967
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Closure Type Crimp
Format Cap and PTFE/silicone Septum
GlassType Black Aluminum
Units in Package 100/pkg

info

WAT052855 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT052855

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052855 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT052855
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054875 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT054875

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT054875 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT054875
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186003848 - Nova-Pak Cyano (CN) Column, 60Å, 4 µm, 3.9 mm X 100 mm, 1/pkg

Part Number: 186003848

Nova-Pak HP CN columns are silica-based, cyano phases that are based on 4 µm particle technology. These columns can be used to achieve unique compound selectivity for both normal-phase and reversed-phase applications.

186003848 - Nova-Pak Cyano (CN) Column, 60Å, 4 µm, 3.9 mm X 100 mm, 1/pkg
Part Number: 186003848
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3
Chemistry Cyano (CN)
Endcapped Yes
Format Column
ID 3.9 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT044243 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT044243

Nova-Pak HP CN columns are silica-based, cyano phases that are based on 4 µm particle technology. These columns can be used to achieve unique compound selectivity for both normal-phase and reversed-phase applications.

WAT044243 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT044243
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3
Chemistry Cyano (CN)
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046830 - Nova-Pak C8 Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046830

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT046830 - Nova-Pak C8 Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046830
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 2/pkg
pH Range 2 - 8

info

WAT044455 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT044455

Nova-Pak HP CN columns are silica-based, cyano phases that are based on 4 µm particle technology. These columns can be used to achieve unique compound selectivity for both normal-phase and reversed-phase applications.

WAT044455 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT044455
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3
Chemistry Cyano (CN)
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT036985 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036985

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT036985 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036985
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT056905 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT056905

Nova-Pak HP CN columns are silica-based, cyano phases that are based on 4 µm particle technology. These columns can be used to achieve unique compound selectivity for both normal-phase and reversed-phase applications.

WAT056905 - Nova-Pak Cyano (CN) Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT056905
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3
Chemistry Cyano (CN)
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052735 - Nova-Pak C8 Column, 60Å, 4 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: WAT052735

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052735 - Nova-Pak C8 Column, 60Å, 4 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: WAT052735
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035890 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg

Part Number: WAT035890

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035890 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg
Part Number: WAT035890
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Radial-Pak Cartridge
ID 5 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186003663 - XBridge Peptide BEH C18 Column, 300Å, 10 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003663

The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003663 - XBridge Peptide BEH C18 Column, 300Å, 10 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003663
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 12
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12