Product Listing:  WAT044238 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, DMF , 1/pkg   to   186002051 - Oasis MCX 2.1 X 20 mm Online Cartridge Column, 30 µm Particle Size, 1/pk

Sorted by Best Sellers
  Product    
info

WAT044238 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, DMF , 1/pkg

Part Number: WAT044238

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044238 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, DMF , 1/pkg
Part Number: WAT044238
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 20K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 2
Solvent DMF
Units in Package 1/pkg
pH Range 2 - 12

info

186002993 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg

Part Number: 186002993

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186002993 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg
Part Number: 186002993
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186004503 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 100 mm, 10K - 500K, 1/pkg

Part Number: 186004503

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004503 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 100 mm, 10K - 500K, 1/pkg
Part Number: 186004503
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

700003755 - Check Valve, Double Ball & Seat, 2/pkg

Part Number: 700003755

ACQUITY Check Valve, Double Ball & Seat, (2PK)

700003755 - Check Valve, Double Ball & Seat, 2/pkg
Part Number: 700003755
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
Products ACQUITY APC pISM
ACQUITY I-Class BSM
Replacement Schedule As Needed

info

700004518 - Source/Cone Tool

Part Number: 700004518

This spare part is a Waters Quality part.

700004518 - Source/Cone Tool
Part Number: 700004518
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

WAT027061 - Porapak Q 100-120 mesh, 26 grams

Part Number: WAT027061

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027061 - Porapak Q 100-120 mesh, 26 grams
Part Number: WAT027061
Products > Chromatography Consumables & Columns > Accessories > Gas Chromatography Packings
Category All Gas Packings

info

6490506-S3 - Fused Silica Tube, 50-micron ID, 3m

Part Number: 6490506-S3

The Fused Capillary Tube, 50µm ID is used for the Steam Select Module on the CapLC XE System.

6490506-S3 - Fused Silica Tube, 50-micron ID, 3m
Part Number: 6490506-S3
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Capillary LC
Products CapLC XE System
Replacement Schedule As Needed

info

WAT054515 - Sep-Pak Aminopropyl (NH2) 20 cc Vac RC Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT054515

Sep-Pak Amino Propyl (NH2) Vac RC cartridges contain a moderately polar, silica-based bonded phase with weakly basic surface. The sorbent can be used as a polar sorbent with different selectivity for acidic/basic analytes or as a weak anion exchanges in aqueous medium below pH 8. Applications include extraction of phenols and phenolic pigments, petroleum fractionation, saccharides and drugs and metabolites. These cartridges feature an integral 20 cc funnel-shaped reservoir for convenient processing of larger volumes of samples. They can be used with robotic sample preparation equipment or with vacuum manifolds.

WAT054515 - Sep-Pak Aminopropyl (NH2) 20 cc Vac RC Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT054515
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 20 cc
Chemistry Aminopropyl (NH2)
Endcap End Capped
Format/Type Vac RC Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 500 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

700005346 - Corona Discharge Pin

Part Number: 700005346

This spare part is a Waters Quality part.

700005346 - Corona Discharge Pin
Part Number: 700005346
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SQ Detector 2
SYNAPT G2-S
Xevo TQD
Xevo™ TQ MS
Replacement Schedule As Needed

info

176003868 - GlycoWorks Rapid Deglycosylation Kit - 3x8

Part Number: 176003868

The GlycoWorks Rapid Deglycosylation Kits are used to support existing RapiFluor-MS (RFMS) customers who are looking to qualify and validate their deglycosylation efficiency with the protocol. It can also be used for complimentary application areas to compare intact with partial PNGase F deglycosylation for site occupancy information (quick screening) and intact O-linked analysis as shown through application notes in the below references with the Waters ACQUITY UPLC Glycoprotein BEH Amide, 300A column. The GlycoWorks Rapid Deglycosylation Kit- 3x8 specifically supports the 24 sample protocol that contains enough reagents to complete 3, 8 reaction sample sets. GlycoWorks Deglycosylation Module: (1) 0.035 ml/vial Rapid PNGaseF Enzyme (1) 0.25 ml/vial Glycoworks Rapid Buffer (3) 3 vials of 3 mg/vial RapiGest™ SF Surfactant

176003868 - GlycoWorks Rapid Deglycosylation Kit - 3x8
Part Number: 176003868
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 20/pkg
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186006549 - ACQUITY UPLC Protein BEH C4 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006549

This kit consists of three ACQUITY UPLC BEH300 C4 PrST columns packed with three different batches of sorbent.

186006549 - ACQUITY UPLC Protein BEH C4 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186006549
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

289003345 - Mixer Assy, 1.0 x 50mm, Zirc Bead

Part Number: 289003345

The Mixer Assy, 1.0 x 50mm, Zirc. Bead is part of the Mixer Kit for 1mm column, p/n 205000540.

289003345 - Mixer Assy, 1.0 x 50mm, Zirc Bead
Part Number: 289003345
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category nanoACQUITY
Products nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

205000242 - 80µL Sideport Syringe Kit

Part Number: 205000242

This spare part is a Waters Quality part.

205000242 - 80µL Sideport Syringe Kit
Part Number: 205000242
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products 2777 Compact Sample Manager
Replacement Schedule As Needed

info

WAT030654 - Protein-Pak Epoxy Activated Affinity Material - 100g

Part Number: WAT030654

Waters Protein-Pak™ Epoxy-Activated affinity products are silica-based materials with nominal 40 ?m particle diameter and nominal 500 Å pore size. The packing is epoxy-activated for ligand coupling. It is capable of rapid purification of large sample volumes at high flow rates.

WAT030654 - Protein-Pak Epoxy Activated Affinity Material - 100g
Part Number: WAT030654
Brand: Protein-Pak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Protein-Pak Columns
Chemistry Affinity
Endfitting Type Waters
Format Bulk
Mode Affinity
Particle Shape Spherical
Particle Size (dp) 37-55 µm
Particle Substrate Silica
Pore Size 300Å
Units in Package 1/pkg
pH Range 2 - 8

info PSL613317 - PEEK TEE W FINTIGHT FITTINGS
Part Number: PSL613317
Products > Chromatography Consumables & Columns > Accessories > Fittings

info

700002231 - 20µL Sideport Syringe w/o Needle

Part Number: 700002231

This spare part is a Waters Quality part.

700002231 - 20µL Sideport Syringe w/o Needle
Part Number: 700002231
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products 2777 Compact Sample Manager
2777 Sample Manager
Replacement Schedule As Needed

info

186008079 - QuEChERS 900 mg MgSO4, 450 mg PSA, 300 mg C18 and 50 mg GCB, 15 mL Tube, 50/pkg

Part Number: 186008079

This is clean-up tube used for the extract from step 1 in QUECHERS sample preparation. This d-SPE tube contains PSA, C18 and GCB for the clean up of fatty and pigmented samples. QUECHERS (pronounced catchers) methods are used for multi-pesticide residue analyses in food. This is a 50 pack of tubes containing the d-SPE components.

186008079 - QuEChERS 900 mg MgSO4, 450 mg PSA, 300 mg C18 and 50 mg GCB, 15 mL Tube, 50/pkg
Part Number: 186008079
Brand: DisQuE

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 15 mL
Chemistry Dispersive
Format/Type Tube
Units In Package 50/pkg

info

186008204 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008204

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186008204 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008204
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008175 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008175

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186008175 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008175
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT089592 - PrepPak® 1000 Module

Part Number: WAT089592

This spare part is a Waters Quality part.

WAT089592 - PrepPak® 1000 Module
Part Number: WAT089592
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

This spare part is a Waters Quality part.

info

186000195 - Symmetry C18 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186000195

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

186000195 - Symmetry C18 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186000195
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Symmetry300 Columns
% Carbon Load 8.5
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 300Å
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

WAT043370 - Sep-Pak Florisil 20 cc Vac Cartridge, 5 g Sorbent per Cartridge, 50-200 µm Particle Size, 20/pk

Part Number: WAT043370

Polar, highly active, weakly basic sorbent for adsorption of low to moderate polarity species from nonaqueous solutions.

WAT043370 - Sep-Pak Florisil 20 cc Vac Cartridge, 5 g Sorbent per Cartridge, 50-200 µm Particle Size, 20/pk
Part Number: WAT043370
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 20 cc
Chemistry Florisil
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Normal-phase
Particle Size 50-200 µm
Pore Size 60Å
Sorbent Substrate Florisil
Sorbent Weight 5 g
Units In Package 20/pkg
Water Wettable Water Wettable

info

186008717 - Oasis PRiME HLB 3 cc Vac Cartridge, 150 mg Sorbent per Cartridge, 100/pk

Part Number: 186008717

Oasis PRiME HLB sets the new performance standard for solid phase extraction cleanup in routine analysis. This sorbent will provide reversed-phase cleanup of acidic, basic and neutral compounds form complex sample matrices. Oasis PRiME HLB has been designed to simplify SPE with easy to follow protocols. It also produces cleaner samples by removing greater than 95% of common matrix interferences such as salts, proteins and phospholipids. Additionally, viscous samples can be processed with faster flows through the device and less plugging. When using the pass-thru protocol, the 3 cc cartridge with 150 mg sorbent can be used to clean up more sample compared to the cartridge with 60 mg sorbent. The additional volume of extract can be further concentrated for sample enrichment.

186008717 - Oasis PRiME HLB 3 cc Vac Cartridge, 150 mg Sorbent per Cartridge, 100/pk
Part Number: 186008717
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry PRiME HLB
Format/Type Vac Cartridge
Sorbent Weight 150 mg
Units In Package 100/pkg
Water Wettable Water Wettable

info

186005323 - XSelect CSH Fluoro Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186005323

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005323 - XSelect CSH Fluoro Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186005323
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186001179 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186001179

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001179 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186001179
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

PSS831114 - Spherisorb Amino (NH2) Column, 80Å, 5 µm, 4.6 mm X 200 mm, 1/pkg

Part Number: PSS831114

Spherisorb NH2 (Amino) columns contain a silica-based aminopropyl bonded sorbent. The column is listed as USP L8 and is used for anion-exchange, normal-phase and HILIC separations.

PSS831114 - Spherisorb Amino (NH2) Column, 80Å, 5 µm, 4.6 mm X 200 mm, 1/pkg
Part Number: PSS831114
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 1.9
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 200 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

WAT073633 - Semi-Prep Sample Loop Kit

Part Number: WAT073633

The Semi-Prep Sample Loop Kit contains one 50µL sample loop and one 200µL Sample Loop.

WAT073633 - Semi-Prep Sample Loop Kit
Part Number: WAT073633
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Injectors
Products FlexInject Manual Dual Injector Module
Replacement Schedule As Needed

info

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052587

The Waters® Performance Maintenance Kit for the 515 pump contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: two Clear-100™ plunger seals, two standard sapphire plungers, one solvent filter, one diffuser, four PerformancePLUS™ Check Valve Cartridges and thin wall Teflon Tubing.

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052587
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products 515 HPLC Pump
Replacement Schedule Annually

info

700002478 - T27 Torx Screws

Part Number: 700002478

This spare part is a Waters Quality part.

700002478 - T27 Torx Screws
Part Number: 700002478
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Nuts/bolts/screws
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
2796 Bioseparations Module
Replacement Schedule As Needed

info

186002051 - Oasis MCX 2.1 X 20 mm Online Cartridge Column, 30 µm Particle Size, 1/pk

Part Number: 186002051

The Oasis MCX on-line cartridge column is designed for rugged, reproducible, and ultra-fast on-line SPE. This cartridge column contains the Oasis MCX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. This on-line cartridge column is designed to be used with the appropriate Waters narrow-bore analytical column, such as XSelect, XBridge, SunFire, Atlantis, XTerra, or Symmetry column. The Oasis MCX on-line cartridge column fits into a Sentry holder that features a finger-tight fitting for fast, convenient replacement.

186002051 - Oasis MCX 2.1 X 20 mm Online Cartridge Column, 30 µm Particle Size, 1/pk
Part Number: 186002051
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry MCX
Format/Type Online Cartridge Column
Ion Exch. Capacity 1 meq/gram
Length 20 mm
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH