Product Listing:  186005945 - XSelect HSS Cyano (CN) Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg   to   186006703 - Preparative Chromatography Mix Standard

Sorted by Best Sellers
  Product    
info

186005945 - XSelect HSS Cyano (CN) Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186005945

The XSelect HSS CN chemistry is an ultra-performance general purpose propyl cyano bonded phase that provides superior peak shape for bases, increased retention, and extremely long column lifetimes at low pH. XSelect HSS CN HPLC columns are fully scalable and transferable to ACQUITY UPLC separations.

186005945 - XSelect HSS Cyano (CN) Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186005945
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

667003976 - Empower 3 Enterprise System Suitability

Part Number: 667003976

Calculates all System Suitability parameters described in the different Pharmacopoeia USP, EP and JP. Performs statistical calculations on results as repeatability and summarizes the information in graphical or tabular formats. Allows you to specify the control limits or warning limits to flag out of specifications (OOS) values. Develop custom reports with trend plots and statistics, summary graphics to highloght OOS values.

667003976 - Empower 3 Enterprise System Suitability
Part Number: 667003976
Products > Chromatography Consumables & Columns > Accessories
Product Compatibility Empower 3 all versions
Quantity 1

info

205000291 - Column Stabilizer Kit, 50/100mm

Part Number: 205000291

Column Stabilizer Kit, 50-100mm (original column heater)

205000291 - Column Stabilizer Kit, 50/100mm
Part Number: 205000291
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category ACQUITY
Products ACQUITY UPLC Column Heater Module
ACQUITY UPLC Column Heater/Cooler
Replacement Schedule As Needed

info WAT010001 - PREP C18 55-105 UM 125A 1KG
Part Number: WAT010001
Products > Chromatography Consumables & Columns > Accessories

info

176004082 - Glycoworks RFMS N-Gly Kit-8x12

Part Number: 176004082

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in as little as 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS's (RFMS) unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive. This kit includes the GlycoWorks Deglycosylation Module, GlycoWorks Labeling Module, GlycoWorks Clean-up Module, GlycoWorks Sample Collection Module. It contains materials to process 96 samples in an 8x12 format. The kit contains: GlycoWorks Deglycosylation Module (4 Boxes): (1) 0.035 ml/vial Rapid PNGaseF Enzyme (1) 0.25 ml/vial Glycoworks Rapid Buffer (1) 3 vials of 3 mg/vial RapiGest™ SF Surfactant (1) Intact mAb Mass Check Standard *Shipped in a separate box only one per kit GlycoWorks RapiFluor-MS Labeling Module (4 Boxes): (3) 9 mg/vial RapiFluor-MS Reagent (3) 1 mL/vial Reagent Solvent (Anhydrous DMF) GlycoWorks RFMS Clean-up Module: (4) 0.5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7) (4) 3 ml/vial Sample Diluent (DMF/ACN Mixture) (1) GlycoWorks HILIC µElution Plate GlycoWorks Sample Collection Module: (15) 1 mL tubes for deglycosylation and labeling reaction (15) 600 µL tube inserts for SPE eluate collection (15) Cap strips with slits for direct injection (1) 1 mL round collection tray (1) Waste tray

176004082 - Glycoworks RFMS N-Gly Kit-8x12
Part Number: 176004082
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging Kit
Product Type Kit
Shipping Formulation Liquid & Solid
System LC/MS

info

PSS830715 - Spherisorb ODS1 Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830715

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS830715 - Spherisorb ODS1 Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830715
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700003556 - Ferrule, Capillary Adapter, Polyimide

Part Number: 700003556

This spare part is part of the NanoLockspray Option.

700003556 - Ferrule, Capillary Adapter, Polyimide
Part Number: 700003556
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category Mass Spectrometry
Products Q-Tof Premier Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

WAT015220 - Nova-Pak C18 Guard-Pak Insert, 60Å, 4 µm, 10/pkg

Part Number: WAT015220

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT015220 - Nova-Pak C18 Guard-Pak Insert, 60Å, 4 µm, 10/pkg
Part Number: WAT015220
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Format Guard-Pak Insert
Particle Size (dp) 4 µm
Pore Size 60Å
System HPLC
Units in Package 10/pkg

info

205000362 - Needle, Stainless Steel, 30µL

Part Number: 205000362

This spare part is a Waters Quality part.

205000362 - Needle, Stainless Steel, 30µL
Part Number: 205000362
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
nanoACQUITY
Products ACQUITY UPLC Sample Manager
nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

700000461 - Z-Spray Source Consum. Kit

Part Number: 700000461

Kit containing replacements for consumable items on the Z-Spray source.

700000461 - Z-Spray Source Consum. Kit
Part Number: 700000461
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Nuts/bolts/screws
Product Category Mass Spectrometry
Products Platform LCZ Mass Detector
ZMD Mass Spectrometer
Replacement Schedule As Needed

info

205000610 - Flowcell, ACQUITY TUV, 5mm, SS

Part Number: 205000610

This new stainless steel flowcell will fit into existing ACQUITY TUV Detectors with serial number K05UPT700N and above. The fluidic connections will be the same as for the existing flowcells. The new flowcell has a robust design and has a decreased pathlength of 5mm.

205000610 - Flowcell, ACQUITY TUV, 5mm, SS
Part Number: 205000610
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

186006012 - Hi3 Ecoli Standard

Part Number: 186006012

The Hi3 Ecoli and Phos B standards are a specialized set of 6 synthetically prepared and highly purified peptides that provide the top 6 ionizing peptides of both the E.coli ClpB and rabbit Phosphorylase B proteins. These standards are quantitated via AAA to equimolar ratios to provide greater accuracy to each analysis. They are greater than 95% pure and have been verified by mass identification. These standards are primarily intended for use with the Hi3 quantification method for MSE proteomics data processed with ProteinLynx Global Server. The E. coli standard is intended for samples of animal origin, and the Phos B standard is intended for samples of microbial origin. The standards may also be of use in the evaluation and benchmarking of proteomic LC/MS systems comprised of nanoACQUITY UPLC and Synapt and Xevo time-of-flight mass spectrometers.

186006012 - Hi3 Ecoli Standard
Part Number: 186006012
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Pharmaceutical and Life Science Standards & Kits > Peptide Standards & Kits > Peptide Standards and Kits
Applications Life Science
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
Storage Room temp
System Proteomics

info

WAT073005 - PTFE Septum, 1440/pkg

Part Number: WAT073005

Waters offers a selection of cap, septum, and assembled cap/septum for various vial sizes. The range of septum material is limited to PTFE, silicone / PTFE, and polyethylene septumless caps.

WAT073005 - PTFE Septum, 1440/pkg
Part Number: WAT073005
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Bruker
Kontron
Perkin-Elmer
Shimadzu
Tosoh
Unicam
Waters 700 Series
Certified Not Certified
Format PTFE Septum
Units in Package 1440/pkg

info

700002332 - PerformancePLUS Check Valve Housing

Part Number: 700002332

This spare part is a Waters Quality part.

700002332 - PerformancePLUS Check Valve Housing
Part Number: 700002332
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Separations Module
Products 2695 Separations Module
2795 Separations Module
Replacement Schedule As Needed

info

186004027 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186004027

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186004027 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186004027
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700007688 - P-200A Pump Preventative Maintenance Kit

Part Number: 700007688

This kit contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Kit includes the following parts: plungers, check valves, seals and filters.

700007688 - P-200A Pump Preventative Maintenance Kit
Part Number: 700007688
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category SFC
Products P200 Pump
Replacement Schedule Annually

info

186003454 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003454

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186003454 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003454
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format Prep Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

PSS839535 - Spherisorb C8 Cartridge, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS839535

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS839535 - Spherisorb C8 Cartridge, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS839535
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT043460 - Sep-Pak Accell Plus QMA Vac RC Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT043460

Sep-Pak Accell Plus QMA Vac RC cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These cartridges feature an integral 20 cc funnel-shaped reservoir for convenient processing of larger volumes of samples. They can be used with robotic sample preparation equipment or with vacuum manifolds.

WAT043460 - Sep-Pak Accell Plus QMA Vac RC Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT043460
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA
Format/Type Vac RC Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

201000193 - ACQUITY FLR DETECTOR PERFORMANCE MAINTENANCE KIT

Part Number: 201000193

The Waters® Performance Maintenance Kit for the ACQUITY Fluorescence Detector contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: lamp.

201000193 - ACQUITY FLR DETECTOR PERFORMANCE MAINTENANCE KIT
Part Number: 201000193
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC Fluorescence Detector
Replacement Schedule Annually

info

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing

Part Number: 186006613

0.005 x 1.75 UPLC SEC Connection Tubing

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing
Part Number: 186006613
Products > Chromatography Consumables & Columns > Accessories > Tubing
Hardware Type Tubing
Inside Diameter 0.005 in. (0.127 mm)

info

WAT052256 - Needle Luer 22AWG (.016 ID)

Part Number: WAT052256

This spare part is a Waters Quality part.

WAT052256 - Needle Luer 22AWG (.016 ID)
Part Number: WAT052256
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products Rheodyne Injector
Replacement Schedule As Needed

info

WAT037372 - Compression Screw, 1/8in. Tefzel, 5/Pkg

Part Number: WAT037372

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT037372 - Compression Screw, 1/8in. Tefzel, 5/Pkg
Part Number: WAT037372
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Separations Module
Systems Components
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
ACQUITY UPLC Binary Solvent Manager
In-Line Degasser

info

186001307 - Atlantis dc18 Column, 100Å, 3 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186001307

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001307 - Atlantis dc18 Column, 100Å, 3 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186001307
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

430001084 - Tube Assy. Inject Outlet, UPLC

Part Number: 430001084

ACQUITY SM Injector Outlet Tube Assembly, .005 ID x 11 inches long

430001084 - Tube Assy. Inject Outlet, UPLC
Part Number: 430001084
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

186002803 - Amber Glass 12 x 32mm Screw Neck Qsert Vial, 300 µL Volume, 100/pkg

Part Number: 186002803

For more information on the complete line of Waters vials, please download Waters latest brochure on vials and accessories.

186002803 - Amber Glass 12 x 32mm Screw Neck Qsert Vial, 300 µL Volume, 100/pkg
Part Number: 186002803
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Gilson
Hitachi
LDC
Perkin-Elmer
Shimadzu
Spark
Spectra-Physics
Varian
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Qsert Vial
GlassType Amber Glass
Units in Package 100/pkg
Volume Capacity 300 µL

info

PSS831013 - Spherisorb C6 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS831013

Spherisorb C6 columns are general purpose, silica-based reversed-phase columns that contain a linear-hexyl ligand. These USP L15 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS831013 - Spherisorb C6 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS831013
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.7
Chemistry C6
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L15
Units in Package 1/pkg
pH Range 2 - 8

info

186007365 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186007365

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007365 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186007365
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700000987 - Valco Fittings, 1/16in., SS, 5/pkg

Part Number: 700000987

The Valco Fittings Kit contains 5 each of the compression screws and ferrules with 1/16 inch ID.

700000987 - Valco Fittings, 1/16in., SS, 5/pkg
Part Number: 700000987
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Capillary LC
Pumps
Products 2525 Binary Gradient Module
2545 Binary Gradient Module
CapLC System
CapLC XE System
Replacement Schedule As Needed

info

186006703 - Preparative Chromatography Mix Standard

Part Number: 186006703

The Quality Control Reference Material portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientist. The Preparative Chromatography Standard is 5 mg/mL each of Diclofenac sodium salt, Diphenhydramine hydrochloride, and Flavone in DMSO. This standard mix should be used to confirm the benchmark performance of your Preparative/purification system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic and basic compounds. It can be used with a variety of column chemistries and dimensions, and system hardware.

186006703 - Preparative Chromatography Mix Standard
Part Number: 186006703
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Column Chemistry C18 RP
Detector Mass Spec
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS