Product Listing:  186008843 - RapiFluor-MS Intact mAb Standard   to   PSS845281 - Spherisorb C8 Column, 80Å, 5 µm, 4 mm X 250 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

186008843 - RapiFluor-MS Intact mAb Standard

Part Number: 186008843

The RapiFluor-MS Intact mAb Mass Check Standard is intended to be used for method familiarization, troubleshooting, and benchmarking. It is the labeled counterpart to the proficiency control standard, the Intact mAb Mass Check Standard (pn 186006552), that is provided to customers upon their purchase of a GlycoWorks RapiFluor-MS N-Glycan Kit. The RapiFluor-MS Intact mAb Mass Check Standard contains RapiFluor-MS labeled, released N-glycans obtained from 30 µg of Intact mAb Mass Check Standard and contains 400 pmol/vial.

186008843 - RapiFluor-MS Intact mAb Standard
Part Number: 186008843
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
System LC/MS

info

6060743-S1 - Tube PTFE 1/16 " OD, 0.015" ID, 1m

Part Number: 6060743-S1

1m length of PTFE tube (1/16 OD, 0.015 ID).

6060743-S1 - Tube PTFE 1/16 " OD, 0.015" ID, 1m
Part Number: 6060743-S1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products Xevo TQD
Replacement Schedule As Needed

info

186008791 - RapiFluor-MS Quantitative Glycan Standard

Part Number: 186008791

The RapiFluor-MS Quantitative Test Standard (RapiFluor-MS -TPTTQSSVSSQTTR-OH) is intended to be used to quantify absolute amounts of RapiFluor-MS labeled analytes using fluorescence response and to assess the yields and proficiency of sample preparations. Each vial of RapiFluor-MS Quantitative Test Standard contains a lyophilized, highly purified synthetic peptide that has been derivatized with a single RapiFluor-MS label. It is purposefully designed to elute via HILIC chromatography with a GU (glucose unit) value of approximately 4. It is QC-tested to ensure that it is quantitatively packaged at 100 pmol per vial.

186008791 - RapiFluor-MS Quantitative Glycan Standard
Part Number: 186008791
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
System LC/MS

info

186002647 - Red, 12 x 32mm Snap Neck Cap and preslit PTFE/silicone Septum, 100/pkg

Part Number: 186002647

Waters offers a selection of cap, septum, and assembled cap/septum for various vial sizes. The range of septum material is limited to PTFE, silicone / PTFE, and polyethylene septumless caps.

186002647 - Red, 12 x 32mm Snap Neck Cap and preslit PTFE/silicone Septum, 100/pkg
Part Number: 186002647
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Certified Not Certified
Closure Type Snap Neck
Color Red
Dimensions 12 x 32mm
Format Cap and preslit PTFE/silicone Septum
Units in Package 100/pkg

info

186008764 - XSelect Peptide HSS T3 C18 Column, 100Å , 2.5 µm, 4.6 x 150 mm, 1/pkg

Part Number: 186008764

Peptide HSS T3 Columns are designed for separations where silica-based selectivities are desired or when increased retention of hydrophilic peptides are required.

186008764 - XSelect Peptide HSS T3 C18 Column, 100Å , 2.5 µm, 4.6 x 150 mm, 1/pkg
Part Number: 186008764
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025820 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg

Part Number: WAT025820

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025820 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg
Part Number: WAT025820
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 7.8 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700003115 - Collet, Reusable, HPFT, 2/pkg

Part Number: 700003115

ACQUITY Reusable Collet, HPFT, (2PK) used on Column Heaters

700003115 - Collet, Reusable, HPFT, 2/pkg
Part Number: 700003115
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY UPLC High Temperature Column Heater
ACQUITY UPLC Column Heater Module
Replacement Schedule As Needed

info

176001744 - PFC Analysis Kit

Part Number: 176001744

Waters ACQUITY UPLC total solution for the analysis of Perfluorinated Compounds (PFCs). The kit contains ACQUITY BEH C18 column, PFC isolator column, and other PFCs-free components optimized for use with the ACQUITY system. Sample preparation consumables such as Oasis HLB cartridges, PFC calibration standards, PFC unknown QC standards, and sample vials are also included.

176001744 - PFC Analysis Kit
Part Number: 176001744
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column Kit

info

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000113

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000113
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008694 - CORTECS UPLC Shield RP18 Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186008694

CORTECS Shield RP18 columns provides complimentary selectivity to C8 and C18 stationary phases. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The solid core particle morphology offers high efficiency and lower backpressures when compared to fully porouse particles of similar particle size.

186008694 - CORTECS UPLC Shield RP18 Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186008694
Brand: CORTECS

Products > Chromatography Consumables & Columns
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info 186004631 - Assembled 12 x 32 mm Total Recovery Vial with PTFE/Silicone Septum 100 pack
Part Number: 186004631
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2690
Waters 2695
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 1.1 mL

info

WAT025656 - Sapphire Plunger

Part Number: WAT025656

Made from the highest quality sapphire, this plunger preserves the life span of the plunger seal. Precise roundness and smoothness tolerances minimize the wear of the plunger seal. Careful concentric alignment of the plunger within its stainless steel holder ensures that the sapphire rides directly into the center of the plunger seal, reducing wear of both parts. Included with the plunger is a pre-mounted C-Clip, which eliminates the need to remount this component.

WAT025656 - Sapphire Plunger
Part Number: WAT025656
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Plungers
Product Category Pumps
Systems
Products 510 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1

info

186004713 - Oasis Peptide Method Development 96 well µElution Plate, 2 mg, 30 µm, 1/pkg

Part Number: 186004713

Oasis Peptide Method Development µElution Plate is designed to simplify the process of sample preparation for the analysis of therapeutic peptides in plasma. The 96-well plate format contains six rows each of two Oasis mixed-mode, ion-exchange chemistries: a strong exchanger (MAX) and a weak cation exchanger (WCX). Sample preparation method development can be quickly and easily achieved with the use of a single SPE protocol. The Oasis Peptide µElution Method Development Plate is sold separately or as a component of the UPLC Therapeutic Peptide Method Development Kit (176001835) and the HPLC Therapeutic Peptide Method Development Kit (176001836).

186004713 - Oasis Peptide Method Development 96 well µElution Plate, 2 mg, 30 µm, 1/pkg
Part Number: 186004713
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Method Development
Format/Type 96-well µElution Plate
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 2 mg
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

205000776 - APH Assembly, Serpentine, SS

Part Number: 205000776

ACQUITY H/I-Class Active Preheater (APH) SS 23.5 inches long

205000776 - APH Assembly, Serpentine, SS
Part Number: 205000776
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC 30cm Column Heater
Replacement Schedule As Needed

info

700003276 - Q-Tof Qualification Standards Kit

Part Number: 700003276

Mass Spectrometry (QToF) standards kit for system assessment. 11 Components: 1. 2 x Vials Leucine Enkephalin 3 mg ±0.15 mg 12 mL Amber Screw top Vial 2. 1 x 25mL Sodium Iodide 25mL 2 µg/µL in 50:50 2-Propanol: Water 30 mL Clear Nalgene Bottle 3. 1 x 12mL Bovine Insulin 3 mg ±0.15 mg 12 mL Amber Screw-top Vial 4. 2 x 15mL Horse Heart Myoglobin 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 5. 2 x 15mL D(+)-Raffinose 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 6. 2 x 4mL [Glu1]-Fibrinopeptide B 0.1 mg ±0.01 mg 4 mL Amber Screw top Vial 7. 1 x 4mL Sodium Hydroxide 2mL 0.1M in Water 4 mL Clear Nalgene Bottle 8. 1x 15mL Haemoglobin (Human) 2.52 mg ±0.125 mg 15 mL Clear Nalgene Bottle 9. 5 x Vials ? - Cyano-4-hydroxycinnamic acid* 10 mg ±0.1 mg Each vial in a sealed foil bag Matrix 10. 1 x 2mL PEG Mix** 2mL 50:50 Acetonitrile: Water +0.2 % Formic 2mL Amber Flame-sealed Ampule w/ cracker PEG Ready Mixed Solution 11. 1 x 2mL PEG Maldi*** 10 mg/mL 50:50 Acetonitrile: Water 2mL Amber Flame-sealed Ampule w/ cracker PEG Maldi Ready Mixed Solution Certificate of Analysis

700003276 - Q-Tof Qualification Standards Kit
Part Number: 700003276
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Frozen -20 C
System LC/MS

info

700002530 - T8 Tubing Kit

Part Number: 700002530

This spare part is a Waters Quality part.

700002530 - T8 Tubing Kit
Part Number: 700002530
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Injectors
Products 2767/2747 Sample Manager
Replacement Schedule As Needed

info

700005980 - Latch Set, CM-A/CM-Aux Trough Cover. L&R

Part Number: 700005980

ACQUITY CMA/CM-Aux Trough Cover Latch Set, Left &Right

700005980 - Latch Set, CM-A/CM-Aux Trough Cover. L&R
Part Number: 700005980
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY APC CM-S
Replacement Schedule As Needed

info

442000182 - Power Cord, IEC C13 10A, India

Part Number: 442000182

Power Cord, IEC C13 10A, India

442000182 - Power Cord, IEC C13 10A, India
Part Number: 442000182
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Cables
Product Category Mass Spectrometry
Products SPECVALUE134881948
SPECVALUE134881949
Replacement Schedule As Needed

info

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg

Part Number: 186007080

The GlycoWorks HILIC 1cc Cartridge Pack contains 20 1cc cartridges for a total of 10 reactions for low sample volume environments. The cartridges are dual purpose; they can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each cartridge is packed with 10 mg of Waters HILIC Solid Phase Extraction (SPE).

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg
Part Number: 186007080
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 20/pkg
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Room temp
System LC/MS

info

186008080 - QuEChERS 750 mg MgSO4, 250 mg PSA, 150 mg C18 and 150 mg Al- N, 15 mL Tube, 50/pkg

Part Number: 186008080

The 15-mL tube is used for cleanup following the extract step in QuEChERS sample preparation. Each d-SPE tube contains PSA, C18 and Alumina neutral sorbents suitable for mycotoxins analysis. QuEChERS (pronounced catchers) methods are used for multi-mycotoxin residue analyses in grains. This package contains 50 d-SPE tubes.

186008080 - QuEChERS 750 mg MgSO4, 250 mg PSA, 150 mg C18 and 150 mg Al- N, 15 mL Tube, 50/pkg
Part Number: 186008080
Brand: DisQuE

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 15 mL
Chemistry Dispersive
Format/Type Tube
Units In Package 50/pkg

info

6436004-S1 - 1/16in. x 0.007in PEEK Tube

Part Number: 6436004-S1

5M Yellow PEEK Tubing

6436004-S1 - 1/16in. x 0.007in PEEK Tube
Part Number: 6436004-S1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
LCT Mass Spectrometer
LCT Premier
LCT Premier XE
Platform LCZ Mass Detector
Q-Tof II Mass Spectrometer
Q-Tof 1 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Premier Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Q-Tof micro Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Xevo Q-Tof Mass Spec
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed

info

700003226 - Cap. Tube Assy., 30µm x 8.2in.

Part Number: 700003226

Capillary Tube, 30-100 mL, 5000:1

700003226 - Cap. Tube Assy., 30µm x 8.2in.
Part Number: 700003226
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info WAT011795 - DeltaPak C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT011795
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: 186004051

Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride counter-ion in the standard Sep-Pak Accell Plus QMA cartridges interferes with the analysis. These Light-style cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: 186004051
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA Carbonate
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 130 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

700005489 - Super F/Less Ferrule C/W SS Ring (5PK)

Part Number: 700005489

This spare part is a genuine Waters Quality Part

700005489 - Super F/Less Ferrule C/W SS Ring (5PK)
Part Number: 700005489
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category Mass Spectrometry
Products SQ Detector 2
SYNAPT G2 HDMS System
SYNAPT G2 MS System
SYNAPT G2-S
Xevo G2 Q-Tof Mass Spec
Xevo G2 TOF Mass Spec
Xevo Q-Tof Mass Spec
Xevo TQ-S MS
Xevo TQD
Replacement Schedule As Needed

info

700006006 - Xevo TQD Standard Kit

Part Number: 700006006

Intended for the verification of Xevo TQD performance, kit includes: Standard 1: 25 mL of Acetominophen (4-Acetamidophenol) @ 20 ng/ul, Caffeine @ 20 ng/ul, Sulfadimethoxine @ 10 ng/ul, Verapamil @ 5 ng/uL Chloramphenicol @ 5 ng/ul and 17-A-Hydroxyprogesterone @ 500 ng/ul in 90% MeOH:10% Water Standard 2: PPG1000 @ 2.5 ng/ul, Triacetyl-B-cyclodextrin @ 5 ng/ul, Verapmil @ 100 pg/ul, Leucine Enkaphalin @ 1 ng/ul Ammonium Acetate @ 0.31 mg/ml in Acetonitrile/Water (1:1 V/V) Standard 3: Sodium Iodide @ 2 µg/ul, Cesium Iodide @ 50 ng/ul in IPA/Water (1:1 V/V) Stanadard 4: 50 mg of Chloramphenicol Solid Standard 5: 5 mg of Reserpine Solid Standard 6: 5 mg of Sulfadimethoxine Solid Standard 7: 3 mL Aqueous Ammonia Standard 8: 2 mL formic acid

700006006 - Xevo TQD Standard Kit
Part Number: 700006006
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186005351 - ACQUITY UPLC CSH Fluoro Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186005351

Designed to maximize selectivity differences, the ACQUITY CSH Fluoro-Phenyl column provides maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005351 - ACQUITY UPLC CSH Fluoro Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186005351
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

WAT200691 - NEEDLE TIPS, PKG OF 20

Part Number: WAT200691
WAT200691 - NEEDLE TIPS, PKG OF 20
Part Number: WAT200691
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info

PSL404219 - Aluminum, Crimp Cap and PTFE/silicone Septum, 100/pkg

Part Number: PSL404219

For more information on the complete line of Waters vials, please download Waters latest brochure on vials and accessories.

PSL404219 - Aluminum, Crimp Cap and PTFE/silicone Septum, 100/pkg
Part Number: PSL404219
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified Not Certified
Closure Type Crimp
Color Aluminum
Format Cap and PTFE/silicone Septum
Units in Package 100/pkg

info

PSS845281 - Spherisorb C8 Column, 80Å, 5 µm, 4 mm X 250 mm, 1/pkg

Part Number: PSS845281

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS845281 - Spherisorb C8 Column, 80Å, 5 µm, 4 mm X 250 mm, 1/pkg
Part Number: PSS845281
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8