186003018 - XBridge BEH C8 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003018

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186003018 - XBridge BEH C8 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003018
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002780 - GlycoWorks HILIC uElution Plate

Part Number: 186002780

This plate is ideal for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. It enables elution volumes as low as 25 µL, thereby eliminating time-consuming evaporation steps. The eluted carbohydrates can be analyzed directly by MALDI MS without any prior derivatization. This plate can be used alone for the purpose of extracting carbohydrates, or it can be used as part of our glycan analysis kit (Waters MassPREP Glycoanalysis Kit) to clean up the glycans released from glycoproteins after deglycosylation.

186002780 - GlycoWorks HILIC uElution Plate
Part Number: 186002780
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Kit
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

WAT082887 - RCM 8X10 CARTRIDGE HOLDER

Part Number: WAT082887
WAT082887 - RCM 8X10 CARTRIDGE HOLDER
Part Number: WAT082887
Products > Chromatography Consumables & Columns > Accessories > Radial Compression

info

186000115 - Oasis HLB 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 30/pk

Part Number: 186000115

The 6 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. The 60 µm particle size is recommended when working with viscous samples. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

186000115 - Oasis HLB 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 30/pk
Part Number: 186000115
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 6 cc
Chemistry HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 60 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 500 mg
Units In Package 30/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003034

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003034
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186005407

ACQUITY CSH Phenyl-Hexyl columns are used to provide alternative analyte selectivity and are a valuable tool for method development. The trifunctionally bonded C6 phenyl ligand is a robust, low bleed sorbents that selectively retains polyaromotic compounds through pi-pi interactions.

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186005407
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

WAT094170 - Low volume insert, 300 µL, 6x29mm with plastic spring 100/pkg

Part Number: WAT094170

Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.

WAT094170 - Low volume insert, 300 µL, 6x29mm with plastic spring 100/pkg
Part Number: WAT094170
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Format Low Volume Inserts and Springs
GlassType Type 1 Class A
Units in Package 100/pkg
Volume Capacity 250 µL

info

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052840

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052840
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT086688 - µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT086688

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT086688 - µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT086688
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6
Chemistry Cyano (CN)
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

186003023 - XBridge BEH C18 Column, 130Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003023

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003023 - XBridge BEH C18 Column, 130Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003023
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186004741

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186004741
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000490

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000490
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186000327C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186000327C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2795
Waters Acquity
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003748

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003748
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT200625 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: WAT200625

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT200625 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: WAT200625
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001337

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001337
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT270946C - LCGC Certified Clear Glass 12 x 32mm screw neck Vial with 10 mm Cap and PTFE/silicone Septum, 2 mL, 100/pkg

Part Number: WAT270946C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

WAT270946C - LCGC Certified Clear Glass 12 x 32mm screw neck Vial with 10 mm Cap and PTFE/silicone Septum, 2 mL, 100/pkg
Part Number: WAT270946C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 2 mL

info

186002853 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002853

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002853 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002853
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003975

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003975
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

WAT200827 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 1000/case

Part Number: WAT200827

This PVDF membrane works well with both aqueous and organic solvents

WAT200827 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 1000/case
Part Number: WAT200827
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Syringe Filter
Hold-up Volume < 30 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Protein
Solvent/Sample Compatible PVDF
Units in Package 1000/case

info WAT200677 - Extraction manifold, 20-position/no rack
Part Number: WAT200677
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories
Category Manifold for Cartridges ( pp 26)

info

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002854

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002854
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

WAT054405 - Styragel Guard Column, 20 µm, 4.6 mm X 30 mm, THF , 1/pkg

Part Number: WAT054405

These Styragel Guard columns protect and increase the column lifetime of your Styragel 7.8 mm or 4.6 mm ID columns.

WAT054405 - Styragel Guard Column, 20 µm, 4.6 mm X 30 mm, THF , 1/pkg
Part Number: WAT054405
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Guard Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 20 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg

Part Number: WAT015209

The Sugar-Pak I Guard-Pak Insert is used to extend and prolong the lifetime for the Sugar Pak I Column by removing chemical and particulate contaminants from the mobile phase stream.

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg
Part Number: WAT015209
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Guard-Pak Insert
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 10/pkg

info

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004742

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004742
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186003839 - AccQ-Tag Ultra Eluent B

Part Number: 186003839

mino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Eluent B is a component of the UPLC® Amino Acid Analysis Application Solution. Eluent B is a concentrate of 950 ml.

186003839 - AccQ-Tag Ultra Eluent B
Part Number: 186003839
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System UPLC

info

WAT026765 - IC-Pak Anion HR Column, 4.6 x 75 mm

Part Number: WAT026765

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026765 - IC-Pak Anion HR Column, 4.6 x 75 mm
Part Number: WAT026765
Brand: IC-Pak HR

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Ion-Exchange
Particle Size (dp) 6 µm
Units in Package 1/pkg

info

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates

Part Number: 186001831

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates
Part Number: 186001831
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

info

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 600000671CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 600000671CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg

Part Number: 186000305

Dark blue polyethylene screw cap with bonded slit septum for 12 x 32 mm vials.

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg
Part Number: 186000305
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Color Blue
Dimensions 12 x 32mm
Format Cap and preslit PTFE/silicone Septum
Units in Package 100/pkg