Product Listing:  186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg   to   WAT084282 - PIC B7 Low UV Reagent

Sorted by Best Sellers
  Product    
info

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002854

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002854
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info WAT201549 - Insulin HMWP SEC Column, 125Å, 10 µm, 7.8 mm X 300 mm, 5K - 150K, 1/pkg
Part Number: WAT201549
Brand: Insulin HMWP

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations
Chemistry SEC
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Gel Filtration (aqueous)
Molecular Weight Range 5K - 150K
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L20
Units in Package 1/pkg
pH Range 2 - 8

info

WAT042887 - UV Detector PQ Standard

Part Number: WAT042887

Kit contains standards appropriate for assessment of HPLC UV systems. 1 Ampule (10 mL standard solution contains): - 10.00 mg/L Acetophenone (+/- 5%) Purity > 99% - 10.00 mg/L Propiophenone (+/- 5%) Purity > 99% - 10.00 mg/L Butyrophenone (+/- 5%) Purity > 99% - 3.2 g/L Acetone (+/- 5%) Purity > 99.74% Solution in 60% HPLC Grade Methanol / 40% HPLC Grade Water, volume/volume.

WAT042887 - UV Detector PQ Standard
Part Number: WAT042887
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186005518 - Ostro Protein Precipitation & Phospholipid Removal Plate, 25 mg, 1/pkg

Part Number: 186005518

Ostro sample preparation products provide a novel solution for the cleanup of phospholipids in plasma and serum. Requiring minimal to no method development and using a simple protocol, the technology can be quickly implemented in order to optimize your laboratory's work flow. Providing cleaner, more reproducible extracts than competitive phospholipid devices or techniques, Ostro allows for more sensitive analyses, increased sample throughput, and reduced instrument downtime.

186005518 - Ostro Protein Precipitation & Phospholipid Removal Plate, 25 mg, 1/pkg
Part Number: 186005518
Brand: Ostro

Products > Chromatography Consumables & Columns > Sample Preparation Products
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Sorbent Weight 25 mg
Units In Package 1/pkg
pH Range 0 - 10 pH

info

186000496 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000496

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000496 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000496
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000442

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000442
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

WAT036820 - Sep-Pak tC18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk

Part Number: WAT036820

Silica-based bonded phase with strong hydrophobicity; trifunctional bonding chemistry gives it an increased hydrolytic stabilty; applications similar to C18.

WAT036820 - Sep-Pak tC18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk
Part Number: WAT036820
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry TC18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT200632 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT200632

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT200632 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT200632
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186004021

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186004021
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT058958 - 96-well Sample collection plate 2mL 50/pkg

Part Number: WAT058958

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

WAT058958 - 96-well Sample collection plate 2mL 50/pkg
Part Number: WAT058958
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
Units in Package 50/pkg
Volume Capacity 2 mL

info

WAT086688 - µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT086688

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT086688 - µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT086688
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6
Chemistry Cyano (CN)
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT034106 - Shodex KF-G Guard Column, 5 µm, 4.6 x 10 mm (THF)

Part Number: WAT034106

Ultrahigh efficiency GPC columns

WAT034106 - Shodex KF-G Guard Column, 5 µm, 4.6 x 10 mm (THF)
Part Number: WAT034106
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Guard Column
ID 4.6 mm
Length (mm) 10 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

186002780 - GlycoWorks HILIC uElution Plate

Part Number: 186002780

This plate is ideal for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. It enables elution volumes as low as 25 µL, thereby eliminating time-consuming evaporation steps. The eluted carbohydrates can be analyzed directly by MALDI MS without any prior derivatization. This plate can be used alone for the purpose of extracting carbohydrates, or it can be used as part of our glycan analysis kit (Waters MassPREP Glycoanalysis Kit) to clean up the glycans released from glycoproteins after deglycosylation.

186002780 - GlycoWorks HILIC uElution Plate
Part Number: 186002780
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Kit
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186004741

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186004741
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003976

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003976
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001830BA

The patented 96-well Oasis MCX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis MCX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis MCX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.

186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Part Number: 186001830BA
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry MCX
Format/Type 96-well µElution Plate
Ion Exch. Capacity 1 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 2 mg
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 600000671CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 600000671CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000490

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000490
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004802 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004802

ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.

186004802 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004802
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001344

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001344
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186000327C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186000327C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2795
Waters Acquity
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

176001235 - AccQ-Tag Ultra Chemistry Kit

Part Number: 176001235

Amino Acid Analysis (AAA) is required for many applications. Refill Package. The refill Kit is intended to recharge the AccQTag Ultra chemistries that are a part of the Application Add on kit. This kit should not be purchased as part of an initial system. Includes AccQTag Ultra Deriviativation Kit 250 analyses 186003836, AccQTag Ultra Column 2.1 X 100mm 186003837, AccQTag Eluent A Concentrate (950mL) 186003838, AccQTag Ultra Eluent B (950mL) 186003839, Sample Tubes, 4 X 72pkg WAT007571, Amino Acid Standard, Hydrolyste, 10 X 1mL ampules WAT088122, Tota Recovery Vials, 3 X 100 vial/pkg 186000384C

176001235 - AccQ-Tag Ultra Chemistry Kit
Part Number: 176001235
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Kit
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System UPLC

info

WAT023525 - Sep-Pak Accell Plus QMA Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT023525

Sep-Pak Accell Plus QMA Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

WAT023525 - Sep-Pak Accell Plus QMA Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT023525
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 130 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

186005380 - XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186005380

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005380 - XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186005380
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001337

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001337
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003462

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003462
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000438

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000438
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm

Part Number: WAT036570

The silica-based IC-Pak C M/D column allows a simultaneous analysis of monovalent and divalent cations under isocratic conditions. This technology provides the analytical chemist with the most sensitive means of analyzing monovalent cations such as Na+, K+, Li+ and NH4+.

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm
Part Number: WAT036570
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 5 µm
Units in Package 1/pkg

info

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186005407

ACQUITY CSH Phenyl-Hexyl columns are used to provide alternative analyte selectivity and are a valuable tool for method development. The trifunctionally bonded C6 phenyl ligand is a robust, low bleed sorbents that selectively retains polyaromotic compounds through pi-pi interactions.

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186005407
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

WAT084282 - PIC B7 Low UV Reagent

Part Number: WAT084282

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B7 Low UV is a 5 vial/pkg of heptane sulfonic acid in a workable UV range in mobile phase 200+ nm.

WAT084282 - PIC B7 Low UV Reagent
Part Number: WAT084282
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV