Product Listing:  WAT270868 - I/O Connector Plug, 12 pin   to   186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg

Sorted by Best Sellers
  Product    
info

WAT270868 - I/O Connector Plug, 12 pin

Part Number: WAT270868

The I/O Connector Plug is a removable connector found on the back of the instrument that holds the 12 pins for the input/output signals.

WAT270868 - I/O Connector Plug, 12 pin
Part Number: WAT270868
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category ACQUITY
Capillary LC
Detectors
Pumps
Separations Module
nanoACQUITY
Products 1515 HPLC Pump
1525 HPLC Pump
2410 Differential Refractive Index Detector
2487 Dual Wavelength Absorbance Detector
2488 Multichannel UV/Vis Detector
2690 Separations Module
2690D Dissolution Separations Module
2790 Separations Module
ACQUITY UPLC Binary Solvent Manager
CapLC 2487
CapLC System
CapLC XE System
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule No

info

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing

Part Number: 186006613

0.005 x 1.75 UPLC SEC Connection Tubing

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing
Part Number: 186006613
Products > Chromatography Consumables & Columns > Accessories > Tubing
Hardware Type Tubing
Inside Diameter 0.005 in. (0.127 mm)

info

186003535 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pkg

Part Number: 186003535

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.

186003535 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pkg
Part Number: 186003535
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT081158 - Semi-Prep Taper Slit Flow Cell

Part Number: WAT081158

The Waters®TaperSlit™ Flow Cell design used in the 2487 detector renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Semi-Prep TaperSlit™ Flow Cell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The Semi-Prep Cell has a 3mm path length and a cell volume of 2.6µL.

WAT081158 - Semi-Prep Taper Slit Flow Cell
Part Number: WAT081158
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

201000174 - ACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT

Part Number: 201000174

The Waters® Performance Maintenance Kit for the ACQUITY Sample Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: air chassis filter, injector outlet tubes, needle, system outlet tubes, inject valve pod, wash syringe, injector syringe, sample loop and o-ring.

201000174 - ACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT
Part Number: 201000174
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule Annually

info

417000146 - 6-port Cheminert Injection Valve, 0.25mm

Part Number: 417000146

This is a 6-port Cheminert Injection Valve, 0.25mm bore (microbore). It includes a 10µL sample loop 0.025mm ID (requires PAL C2VDrive).

417000146 - 6-port Cheminert Injection Valve, 0.25mm
Part Number: 417000146
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Products 2777 Compact Sample Manager
2777 Sample Manager
Replacement Schedule As Needed

info

430001084 - Tube Assy. Inject Outlet, UPLC

Part Number: 430001084

ACQUITY SM Injector Outlet Tube Assembly, .005 ID x 11 inches long

430001084 - Tube Assy. Inject Outlet, UPLC
Part Number: 430001084
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

700000290 - ApCI Probe Assembly

Part Number: 700000290

An atmospheric pressure chemical ionization(APCI) probe introduces the sample to the ion source. The original part number was 725000214. The part number has been changed to p/n 700000290.

700000290 - ApCI Probe Assembly
Part Number: 700000290
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule Annually

info

WAT081157 - Inert Taper Slit Flow Cell

Part Number: WAT081157

The Waters®TaperSlit™ Flow Cell design used in the 2487 detector renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Inert TaperSlit™ Flow Cell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The Inert Cell has a 10mm path length and a cell volume of 10µL.

WAT081157 - Inert Taper Slit Flow Cell
Part Number: WAT081157
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

WAT036790 - Sep-Pak tC18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 37-55 µm Particle Size, 30/pk

Part Number: WAT036790

Silica-based bonded phase with strong hydrophobicity; trifunctional bonding chemistry gives it an increased hydrolytic stabilty. Typical applications include analyte isolation and enrichment from biological, environmental and food samples.

WAT036790 - Sep-Pak tC18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 37-55 µm Particle Size, 30/pk
Part Number: WAT036790
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 6 cc
Chemistry TC18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 500 mg
Units In Package 30/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

6435001-S1 - PVC Tubing 19mm OD x 12mm ID, 1m

Part Number: 6435001-S1

This spare part is a Waters Quality part

6435001-S1 - PVC Tubing 19mm OD x 12mm ID, 1m
Part Number: 6435001-S1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
GCT Mass Spectrometer
LCT Premier
LCT Premier XE
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Replacement Schedule As Needed

info

WAT020540 - Sep-Pak Cyanopropyl (CN) Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT020540

Silica-based polar bonded phase; can be used as less polar alternative to silica in normal-phase applications or as less hydrophobic alternative to C18 or C8 in reversed-phase applications; typical applications include drug metabolites and pesticides.

WAT020540 - Sep-Pak Cyanopropyl (CN) Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT020540
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Cyanopropyl (CN)
Endcap End Capped
Format/Type Plus Short Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Normal-phase
Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186006363 - Reversed-Phase QC Reference Material

Part Number: 186006363

The Quality Control Reference Materials portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientist. The Reversed-Phase QC Reference Material is a significantly complex reference material mixture in that it contains compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. It can be used with a variety of column chemistries and dimensions, and system hardware. The Reversed-Phase QC Reference Material contains 7 compounds including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm the benchmark performance of your analytical HPLC or UPLC system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic and basic compounds. These compounds were vigorously tested and evaluated and chosen because they provide the following advantages: – Excellent benchmark – Good peak shape on UV – Acceptable for use on a variety of column

186006363 - Reversed-Phase QC Reference Material
Part Number: 186006363
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Column Chemistry C18 RP
Detector UV
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186002183 - BioSuite Cation-exchange Column, Non-porous, 2.5 µm, 4.6 mm X 35 mm, 1/pkg

Part Number: 186002183

Waters BioSuite™ ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002183 - BioSuite Cation-exchange Column, Non-porous, 2.5 µm, 4.6 mm X 35 mm, 1/pkg
Part Number: 186002183
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 35 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Polymer
Pore Size Non-porous
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186008053 - Oasis PRiME HLB 96-well Plate, 10 mg Sorbent per Well, 1/pk

Part Number: 186008053

Oasis PRiME HLB sets the new performance standard for solid phase extraction cleanup in routine analysis. This sorbent will provide reversed-phase cleanup of acidic, basic and neutral compounds form complex sample matrices. Oasis PRiME HLB has been designed to simplify SPE with easy to follow protocols. It also produces cleaner samples by removing greater than 95% of common matrix interferences such as salts, proteins and phospholipids. Additionally, viscous samples can be processed with faster flows through the device and and less plugging. Based on the Oasis HLB sorbent technology, this water-wettable sorbent does not require conditioning and equilibration to provide excellent recoveries.

186008053 - Oasis PRiME HLB 96-well Plate, 10 mg Sorbent per Well, 1/pk
Part Number: 186008053
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry PRiME HLB
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Sorbent Weight 10 mg
Units In Package 1/pkg
Water Wettable Water Wettable

info

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg

Part Number: 186000302

Waters offers a selection of snap cap vials and snap caps/septa.

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg
Part Number: 186000302
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified Not Certified
Closure Type Snap Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Units in Package 100/pkg
Volume Capacity 1 mL

info

WAT025248 - Rheodyne 7725I Manual Injector

Part Number: WAT025248

The Rheodyne 7725I Manual Injector is a stand-alone injector that can be used on the 1525 Micro Binary HPLC Pump.

WAT025248 - Rheodyne 7725I Manual Injector
Part Number: WAT025248
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Pumps
Products 1525 Micro HPLC Pump
Rheodyne Injector
Replacement Schedule As Needed

info

186000207 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000207

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

186000207 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000207
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010835 - Sep-Pak Accell Plus QMA Classic Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT010835

Sep-Pak Accell Plus QMA Classic cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These Classic-style cartridges are designed for use with positive displacement by a Luer-tip syringe and can also attach easily to vacuum-assisted flow devices using a male/male adaptor.

WAT010835 - Sep-Pak Accell Plus QMA Classic Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT010835
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA
Format/Type Classic Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186003352 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003352

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003352 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003352
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info 186005587 - Sep-Pak Reservoir 60cc 12/pkg
Part Number: 186005587
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products

info

201000216 - SQD/TQD/3100 PERFORMANCE MAINTENANCE KIT

Part Number: 201000216

The Waters® Performance Maintenance Kit for the SQD/TQD/3100 Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance. The Waters® Performance Maintenance Kit for the SQD/TQD/3100 Mass Spectrometer includes the following parts: Source components, ESI probe components, and vacuum pump components. The original part number was 201000190. This particular part number does not deliver a chemical kit which is required to complete the performance testing. The part number for a Waters® Performance Maintenance Kit and a chemical kit is 176002064

201000216 - SQD/TQD/3100 PERFORMANCE MAINTENANCE KIT
Part Number: 201000216
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule Annually

info

186008079 - QuEChERS 900 mg MgSO4, 450 mg PSA, 300 mg C18 and 50 mg GCB, 15 mL Tube, 50/pkg

Part Number: 186008079

This is clean-up tube used for the extract from step 1 in QUECHERS sample preparation. This d-SPE tube contains PSA, C18 and GCB for the clean up of fatty and pigmented samples. QUECHERS (pronounced catchers) methods are used for multi-pesticide residue analyses in food. This is a 50 pack of tubes containing the d-SPE components.

186008079 - QuEChERS 900 mg MgSO4, 450 mg PSA, 300 mg C18 and 50 mg GCB, 15 mL Tube, 50/pkg
Part Number: 186008079
Brand: DisQuE

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 15 mL
Chemistry Dispersive
Format/Type Tube
Units In Package 50/pkg

info

700003521 - Seal Extraction Tool, .0787 Dia, BSM

Part Number: 700003521

ACQUITY Seal Extraction Tool, .0787 Dia, for I-Class BSM

700003521 - Seal Extraction Tool, .0787 Dia, BSM
Part Number: 700003521
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052587

The Waters® Performance Maintenance Kit for the 515 pump contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: two Clear-100™ plunger seals, two standard sapphire plungers, one solvent filter, one diffuser, four PerformancePLUS™ Check Valve Cartridges and thin wall Teflon Tubing.

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052587
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products 515 HPLC Pump
Replacement Schedule Annually

info

186006348 - 20 Pesticide Mix Standard

Part Number: 186006348

10ug/mL of each: atrazin, atrazin-desethyl, cyanazin, sebuthylazin, simazin, terbuthylazin, hexazinone, chlortoluron, diuron, linuron, metobromuron, metoxuron, monolinuron, metolachlor, Methamidophos, Acephate, Methomyl, Dicrotophos, Buprofenzin, Fenpropimorph in Acetonitrile

186006348 - 20 Pesticide Mix Standard
Part Number: 186006348
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186006842 - BEH450 SEC Protein Standard Mix

Part Number: 186006842

The BEH450 SEC Protein Standard Mix is a 5 component protein mixture (Thyroglobulin, IgG, BSA, Myoglobin, Uracil) used to benchmark ACQUITY UPLC BEH450 SEC, 2.5 µm Columns. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006842 - BEH450 SEC Protein Standard Mix
Part Number: 186006842
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

WAT055840 - Rheodyne Inject Vlv, 7725i, spare

Part Number: WAT055840

The Rheodyne 7725i Inject Valve is available as an option for the 616 LC System. The 7725i is a stainless steel seven port injection valve in which the sample is loaded through a built-in needle port in the front of the valve. It is also used in the Preparative Chromatography Rack for the 25X5 series pumps.

WAT055840 - Rheodyne Inject Vlv, 7725i, spare
Part Number: WAT055840
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Pumps
Products 2545 Quaternary Gradient Pump
FlexInject Manual Dual Injector Module
Rheodyne Injector
Replacement Schedule No

info WAT011390 - Sep-Pak Reservoir 30cc 48/pkg
Part Number: WAT011390
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products

info

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg

Part Number: 186007080

The GlycoWorks HILIC 1cc Cartridge Pack contains 20 1cc cartridges for a total of 10 reactions for low sample volume environments. The cartridges are dual purpose; they can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each cartridge is packed with 10 mg of Waters HILIC Solid Phase Extraction (SPE).

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg
Part Number: 186007080
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 20/pkg
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Room temp
System LC/MS