Product Listing:  WAT084189 - PIC A Low UV Reagent   to   186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

WAT084189 - PIC A Low UV Reagent

Part Number: WAT084189

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC A Low UV is 5 vials/pkg of tertrabutylammonium hydrogen sulfate in a workable UV range in mobile phase 200+ nm.

WAT084189 - PIC A Low UV Reagent
Part Number: WAT084189
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186000404

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186000404
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002979

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002979
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT052885

Amino acid analysis is afundamental process in any protein research. Waters developed a new reagent specific for amino acid derivitization that provides enhanced quantitative accuracy and subpicomole detection for hydrolysate amino acids. We offer a system package consisting of an optimized instrument, prepackaged reagents and extensive documentation.

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT052885
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Amino Acid
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
Units in Package 1/pkg

info

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003953

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003953
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186005297 - ACQUITY UPLC CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186005297

ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns. These ultra-efficient columns overcome peak shape asymmetry and poor loading capacity for basic compounds, column bleed, and rapid mobile-phase re-equilibration.

186005297 - ACQUITY UPLC CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186005297
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

WAT023590 - Sep-Pak C18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk

Part Number: WAT023590

Sep-Pak C18 Vac cartridges contain a hydrophobic, reverse-phase, silica-based bonded phase that is used to adsorb analytes of even weak hydrophobicity from aqueous solutions. The Sep-Pak C18 sorbent is made using the most reproducible bonding technology available, utilizing monofunctional silane chemistry. This sorbent offers a unique selectivity and excellent recovery of anlytes, and is recommended as a general purpose SPE phase for both polar and non-polar analytes. Typical applications include extraction of drugs and their metabolites in serum, plasma or urine, desalting of peptides, isolation of trace organics in environmental water samples and organic acids in beverages. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT023590 - Sep-Pak C18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk
Part Number: WAT023590
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates

Part Number: 186001831

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates
Part Number: 186001831
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

info

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002033

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002033
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

WAT046910 - Holder kit for Cartridge and Guard Columns

Part Number: WAT046910

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

WAT046910 - Holder kit for Cartridge and Guard Columns
Part Number: WAT046910
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

info

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000490

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000490
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003462

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003462
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3

Part Number: 700003776

Three 0.2 µm Inlet/Outlet Frits for 2.1 mm ID UPLC Columns

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3
Part Number: 700003776
Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Units in Package 3/pkg

info

WAT034207 - Pullulan Kit

Part Number: WAT034207

A unique collection of GFC standards for molecular weight determination. 8 Pullulan Standards for aqueous MW Testing at 200mg each of approximate molecular weight standards 5000, 10000, 20000, 50000, 100000, 200000, 400000, 800000

WAT034207 - Pullulan Kit
Part Number: WAT034207
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT094170 - Low volume insert, 300 µL, 6x29mm with plastic spring 100/pkg

Part Number: WAT094170

Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.

WAT094170 - Low volume insert, 300 µL, 6x29mm with plastic spring 100/pkg
Part Number: WAT094170
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Format Low Volume Inserts and Springs
GlassType Type 1 Class A
Units in Package 100/pkg
Volume Capacity 250 µL

info

WAT094171 - Low volume insert, 150 µL, w/plastic spring 100/pkg

Part Number: WAT094171

Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.

WAT094171 - Low volume insert, 150 µL, w/plastic spring 100/pkg
Part Number: WAT094171
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Dimensions 12 x 32mm
Format Low Volume Inserts and Springs
GlassType Type 1 Class A
Units in Package 100/pkg

info

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002732

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002732
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186005407

ACQUITY CSH Phenyl-Hexyl columns are used to provide alternative analyte selectivity and are a valuable tool for method development. The trifunctionally bonded C6 phenyl ligand is a robust, low bleed sorbents that selectively retains polyaromotic compounds through pi-pi interactions.

186005407 - ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186005407
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004742

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004742
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001830BA

The patented 96-well Oasis MCX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis MCX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis MCX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.

186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Part Number: 186001830BA
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry MCX
Format/Type 96-well µElution Plate
Ion Exch. Capacity 1 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 2 mg
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm

Part Number: WAT036570

The silica-based IC-Pak C M/D column allows a simultaneous analysis of monovalent and divalent cations under isocratic conditions. This technology provides the analytical chemist with the most sensitive means of analyzing monovalent cations such as Na+, K+, Li+ and NH4+.

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm
Part Number: WAT036570
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 5 µm
Units in Package 1/pkg

info

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm

Part Number: WAT026770

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm
Part Number: WAT026770
Brand: IC-Pak HC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk

Part Number: WAT094226

The 3 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk
Part Number: WAT094226
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info WAT200677 - Extraction manifold, 20-position/no rack
Part Number: WAT200677
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories
Category Manifold for Cartridges ( pp 26)

info

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg

Part Number: 186000305

Dark blue polyethylene screw cap with bonded slit septum for 12 x 32 mm vials.

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg
Part Number: 186000305
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Color Blue
Dimensions 12 x 32mm
Format Cap and preslit PTFE/silicone Septum
Units in Package 100/pkg

info

WAT085721 - µBondapak C18 Radial-Pak Cartridge, 125Å, 10 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT085721

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

WAT085721 - µBondapak C18 Radial-Pak Cartridge, 125Å, 10 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT085721
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.8
Chemistry C18
Endcapped Yes
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004801 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186004801

ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.

186004801 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186004801
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002350

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002350
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

600000668CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 600000668CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000668CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 600000668CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Beckman
Dynatech
Finnigan
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002854

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002854
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11