Product Listing:  186004445 - XBridge BEH HILIC Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pkg   to   PSS837513 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

186004445 - XBridge BEH HILIC Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186004445

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004445 - XBridge BEH HILIC Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186004445
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186004439 - XBridge BEH HILIC Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186004439

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004439 - XBridge BEH HILIC Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186004439
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186006224 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 3 mm X 100 mm, 3/pkg

Part Number: 186006224

This method validation kit consists of three batches of XBridge BEH HILIC columns packed with three different batches of sorbent

186006224 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 3 mm X 100 mm, 3/pkg
Part Number: 186006224
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 3 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186004446 - XBridge BEH HILIC Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004446

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004446 - XBridge BEH HILIC Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004446
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186006226 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186006226

This method validation kit consists of three batches of XBridge BEH HILIC columns packed with three different batches of sorbent

186006226 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186006226
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186004451 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186004451

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004451 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186004451
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186006222 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186006222

This method validation kit consists of three batches of XBridge BEH HILIC columns packed with three different batches of sorbent

186006222 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 186006222
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186004725 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Part Number: 186004725

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004725 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg
Part Number: 186004725
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186006780 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 3 mm X 150 mm, 3/pkg

Part Number: 186006780

This method validation kit consists of three XBridge BEH HILIC columns packed with three different batches of sorbent. XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006780 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 3 mm X 150 mm, 3/pkg
Part Number: 186006780
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 3 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186004448 - XBridge BEH HILIC Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186004448

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004448 - XBridge BEH HILIC Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186004448
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186004452 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186004452

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004452 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186004452
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186006225 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 50 mm, 3/pkg

Part Number: 186006225

This method validation kit consists of three batches of XBridge BEH HILIC columns packed with three different batches of sorbent

186006225 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 50 mm, 3/pkg
Part Number: 186006225
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186006781 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186006781

This method validation kit consists of three XBridge BEH HILIC columns packed with three different batches of sorbent. XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006781 - XBridge BEH HILIC Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186006781
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 8

info

186000861 - XTerra Shield RP18 Method Validation Kit, 125Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186000861

This kit consists of three XTerra RP 18 columns packed with three different batches of sorbent.

186000861 - XTerra Shield RP18 Method Validation Kit, 125Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186000861
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12

info

186002220 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186002220

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002220 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186002220
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002277 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002277

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002277 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002277
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000862 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186000862

This kit consists of three XTerra RP 18 columns packed with three different batches of sorbent.

186000862 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186000862
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12

info

186001166 - XTerra Shield RP18 Prep Column, 125Å, 10 µm, 7.8 mm X 300 mm, 1/pkg

Part Number: 186001166

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186001166 - XTerra Shield RP18 Prep Column, 125Å, 10 µm, 7.8 mm X 300 mm, 1/pkg
Part Number: 186001166
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 7.8 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002265 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg

Part Number: 186002265

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002265 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg
Part Number: 186002265
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002269 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002269

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002269 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002269
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002257 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002257

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002257 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002257
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002261 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186002261

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002261 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186002261
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002281 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186002281

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002281 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186002281
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002224 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002224

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002224 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002224
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186001944 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186001944

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186001944 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186001944
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002381 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002381

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002381 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002381
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186001940 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186001940

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186001940 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186001940
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002273 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186002273

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002273 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186002273
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

PSS837613 - Spherisorb SCX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS837613

Spherisorb SCX columns contain an anionic silica-based sorbent. This strong cation- exchange sorbent is used to separate positively charged ionic species.

PSS837613 - Spherisorb SCX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS837613
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SCX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837513 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS837513

Spherisorb SCX columns contain an anionic silica-based sorbent. This strong cation- exchange sorbent is used to separate positively charged ionic species.

PSS837513 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS837513
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SCX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
Units in Package 1/pkg
pH Range 2 - 8