Product Listing:  186003815 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 300Å, 1.7 µm, 75 µm X 250 mm, 1/pkg   to   186003977 - ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Sorted by Popularity
  Product    
info

186003815 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 300Å, 1.7 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186003815

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003815 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 300Å, 1.7 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186003815
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001346

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001346
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186000404

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186000404
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045995

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045995
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046970

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046970
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186002544 - SunFire C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186002544

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002544 - SunFire C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186002544
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT066204 - Symmetry C8 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: WAT066204

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066204 - Symmetry C8 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: WAT066204
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT094243 - Symmetry Shield RP 8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT094243

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

WAT094243 - Symmetry Shield RP 8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT094243
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186000109 - Symmetry Shield RP18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000109

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.

186000109 - Symmetry Shield RP18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000109
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000179 - Symmetry Shield RP18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000179

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.

186000179 - Symmetry Shield RP18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000179
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000454 - XTerra MS C18 Column, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186000454

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000454 - XTerra MS C18 Column, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186000454
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000480 - XTerra Shield RP18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000480

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000480 - XTerra Shield RP18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000480
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186003109 - XBridge BEH C18 Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003109

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003109 - XBridge BEH C18 Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186003109
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002033

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002033
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002559

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002559
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: WAT066224

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: WAT066224
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001342

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001342
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT011695

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT011695
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003748

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003748
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000488 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000488

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000488 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000488
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002553

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002553
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000695 - Symmetry C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186000695

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

186000695 - Symmetry C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186000695
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003729

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003729
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003032 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186003032

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003032 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186003032
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000696 - Symmetry C18 Column, 100Å, 3.5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186000696

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

186000696 - Symmetry C18 Column, 100Å, 3.5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186000696
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001344

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001344
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT052880 - AccQ-Fluor Reagent Kit

Part Number: WAT052880

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag-Fluor Reagent Pkg Includes: AccQTagFluor Reagent 1, 5X 6mL Vials Reagent 2A 5 X 3 mg vials, AccQFluor Reagent 2B 5 X 4mL vials. The components of this kit are not available separately.

WAT052880 - AccQ-Fluor Reagent Kit
Part Number: WAT052880
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid & Solid
Storage Room temp
System HPLC -UV

info

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003976

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003976
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003975

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003975
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003977 - ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003977

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003977 - ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003977
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12