Product Listing:  186005765 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg   to   205000443 - Leak Detection Kit

Sorted by Popularity
  Product    
info

186005765 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186005765

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005765 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186005765
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006606 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186006606

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006606 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186006606
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

205000436 - Flow Splitter, 2.0-8.0mL, 100:1

Part Number: 205000436

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000436 - Flow Splitter, 2.0-8.0mL, 100:1
Part Number: 205000436
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000435 - Flow Splitter, 0.5-2mL, 15:1

Part Number: 205000435

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000435 - Flow Splitter, 0.5-2mL, 15:1
Part Number: 205000435
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000437 - Flow Splitter, 8.0-30mL, 1000:1

Part Number: 205000437

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000437 - Flow Splitter, 8.0-30mL, 1000:1
Part Number: 205000437
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000438 - Flow Splitter, 8.0-30mL, 5000:1

Part Number: 205000438

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000438 - Flow Splitter, 8.0-30mL, 5000:1
Part Number: 205000438
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000439 - Flow Splitter, 30-100mL, 5000:1

Part Number: 205000439

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000439 - Flow Splitter, 30-100mL, 5000:1
Part Number: 205000439
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000440 - Flow Splitter, 100-150mL, 10,000:1

Part Number: 205000440

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000440 - Flow Splitter, 100-150mL, 10,000:1
Part Number: 205000440
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

725000182 - Single Valve Kit

Part Number: 725000182

The Single LC Valve kit contains the following: (1) LC valve, (2) LC Valve cables (AUX to valve), (6) Stainless steel comression screws, (6) stainless steel ferrules, (1) wrench, (3) needle seals, (1) 20µL sample loop and tubing.

725000182 - Single Valve Kit
Part Number: 725000182
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Products 2777 Compact Sample Manager
2777 Sample Manager
Replacement Schedule As Needed

info

176002063 - LCT MK II PERFORMANCE MAINTENANCE KIT WTIH CHEMICAL KIT

Part Number: 176002063

The Waters® Performance Maintenance Kit for the LCT MKII Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components and vacuum pump components. The original part number was 201000166 and it was changed to part number 176002062. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002063 - LCT MK II PERFORMANCE MAINTENANCE KIT WTIH CHEMICAL KIT
Part Number: 176002063
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Mass Spectrometer
Replacement Schedule Annually

info

176002077 - QTOF GLOBAL PERFORMAMCE MAINTENANCE KIT WITH CHEMICAL KIT.

Part Number: 176002077

The Waters® Performance Maintenance Kit for the Q-Tof Ultima Global Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components and vacuum pump components. The original part number was 201000176 and it has been changed to part number 176002077. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002077 - QTOF GLOBAL PERFORMAMCE MAINTENANCE KIT WITH CHEMICAL KIT.
Part Number: 176002077
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Q-Tof Ultima Global Mass Spectrometer
Replacement Schedule Annually

info

M805790CC1-S - Inner Source EI

Part Number: M805790CC1-S

This spare part is a Waters Quality part

M805790CC1-S - Inner Source EI
Part Number: M805790CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

176002062 - LCT PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002062

The Waters® Performance Maintenance Kit for the LCT Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components and vacuum pump components. The original part number was 201000166 and it was changed to part number 176002062. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002062 - LCT PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002062
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Mass Spectrometer
Replacement Schedule Annually

info

201000206 - XEVO QTOF NLS (SCROLL) PERFORMANCE MAINTENANCE KIT

Part Number: 201000206

The Waters® Performance Maintenance Kit for the XEVO QTOF NLS (SCROLL) PERFORMANCE MAINTENANCE KIT contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kitincludes the following parts: Source components, ESI probe components and vacuum pump components

201000206 - XEVO QTOF NLS (SCROLL) PERFORMANCE MAINTENANCE KIT
Part Number: 201000206
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Xevo Q-Tof Mass Spec
Replacement Schedule Annually

info

M960082DC1-S - DCI Probe Assembly

Part Number: M960082DC1-S

DCI (Desorption Chemical Ionisation) Probe Assembly

M960082DC1-S - DCI Probe Assembly
Part Number: M960082DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
GCT Premier Mass Spectrometer
Replacement Schedule As Needed

info

186003436 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186003436

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003436 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186003436
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186004712 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186004712

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186004712 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186004712
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004727 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186004727

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004727 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186004727
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186005492 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186005492

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005492 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186005492
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005499 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186005499

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005499 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186005499
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005506 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186005506

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005506 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186005506
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186007294 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186007294

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186007294 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186007294
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

201000226 - QTOF GLOBAL PERFORMANCE MAINTENANCE KIT

Part Number: 201000226

The Waters® Performance Maintenance Kit for the Q-Tof Ultima Global Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components and vacuum pump components. The original part number was 201000176. This particular part number does not deliver a chemical kit which is required to complete the performance testing. Performance Maintenance Kit with Chemical Kit part number is 176002077.

201000226 - QTOF GLOBAL PERFORMANCE MAINTENANCE KIT
Part Number: 201000226
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Q-Tof Ultima Global Mass Spectrometer
Replacement Schedule Annually

info

700004203 - Ion Block Assembly

Part Number: 700004203

This spare part is a Waters Quality part

700004203 - Ion Block Assembly
Part Number: 700004203
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Xevo™ TQ MS
Replacement Schedule As Needed

info

176002055 - QUATTRO ULTIMA/PT PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002055

The Waters® Performance Maintenance Kit for the Quattro Ultima/Ultima Pt Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit for the Quattro Ultima/Ultima Pt Mass Spectrometer includes the following parts: Source components, ESI probe components and vacuum pump components. The original part number was 201000175 and it was changed to part number 176002055. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002055 - QUATTRO ULTIMA/PT PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002055
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Replacement Schedule Annually

info

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit

Part Number: 201000260

The Waters® Performance Maintenance Kit for the ACQUITY I-Class Binary Solvent Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: plungers, check valves, seals and filters.

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit
Part Number: 201000260
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule Annually

info

700005999 - Ion Block Assembly

Part Number: 700005999

Complete ion block assembly, includes cone, heater and extractor cone

700005999 - Ion Block Assembly
Part Number: 700005999
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SQ Detector 2
Xevo TQD
Replacement Schedule As Needed

info

186002478 - µPorasil Silica Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002478

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

186002478 - µPorasil Silica Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002478
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

201000205 - XEVO QTOF NLS (ROTARY) PERFORMANCE MAINTENANCE KIT

Part Number: 201000205

The Waters® Performance Maintenance Kit for the XEVO QTOF NLS (ROTARY) PERFORMANCE MAINTENANCE KIT contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source components, ESI probe components and vacuum pump components.

201000205 - XEVO QTOF NLS (ROTARY) PERFORMANCE MAINTENANCE KIT
Part Number: 201000205
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Xevo Q-Tof Mass Spec
Replacement Schedule Annually

info

205000443 - Leak Detection Kit

Part Number: 205000443

This spare part is a Waters Quality part

205000443 - Leak Detection Kit
Part Number: 205000443
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Pumps
Products 2545 Binary Gradient Module
Replacement Schedule As Needed