Product Listing:  205004335 - Flow Cell, 3mm Copper, WE/Hy-REF   to   186001846 - Symmetry Shield RP 8 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pkg

Sorted by Popularity
  Product    
info

205004335 - Flow Cell, 3mm Copper, WE/Hy-REF

Part Number: 205004335

This spare part is a Waters Quality part.

205004335 - Flow Cell, 3mm Copper, WE/Hy-REF
Part Number: 205004335
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

M960029BC1-S - EI Inner Source Assembly (GCT)y

Part Number: M960029BC1-S

EI Inner Source Assembly (GCT)

M960029BC1-S - EI Inner Source Assembly (GCT)y
Part Number: M960029BC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
Replacement Schedule As Needed

info

186003278 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186003278

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003278 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186003278
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186005424 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005424

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005424 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005424
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005437 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005437

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005437 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005437
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005450 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005450

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005450 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005450
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005705

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005705
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005767 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005767

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005767 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005767
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

205000610 - Flowcell, ACQUITY TUV, 5mm, SS

Part Number: 205000610

This new stainless steel flowcell will fit into existing ACQUITY TUV Detectors with serial number K05UPT700N and above. The fluidic connections will be the same as for the existing flowcells. The new flowcell has a robust design and has a decreased pathlength of 5mm.

205000610 - Flowcell, ACQUITY TUV, 5mm, SS
Part Number: 205000610
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

205015017 - ACQUITY UPLC ID Cell PDA, Analytical

Part Number: 205015017

The ACQUITY UPLC Analytical Flowcell with Intelligent Chip Technology can be used in older detectors but the chip technology feature will not work with those older modules. Newer ACQUITY PDA models with serial number E10UPD761N or E10UPD761A or newer ACQUITY eLambda PDA Models with serial number F10UPD571N or F10UPD571A will have the chip technology feature working in the detectors. THis is the analytical flow cell for the ACQUITY PDA detector.

205015017 - ACQUITY UPLC ID Cell PDA, Analytical
Part Number: 205015017
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC PDA Detector
ACQUITY UPLC eLAmbda PDA Detector
Replacement Schedule As Needed

info

205015006 - Flowcell, ACQUITY PDA, HT, 3mm

Part Number: 205015006

The High Throughput Flow Cell has a 3mm path length and is used on the ACQUITY UPLC PDA Detector and the ACQUITY UPLC eLambda PDA detector.

205015006 - Flowcell, ACQUITY PDA, HT, 3mm
Part Number: 205015006
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC PDA Detector
ACQUITY UPLC eLAmbda PDA Detector
Replacement Schedule As Needed

info

205015013 - ACQUITY TUV Flow Cell, 10nL, nano

Part Number: 205015013

The new Intelligent Chip Technology feature will be added to this flowcell soon. This flowcell will be backwards compatible, but the chip technology information is not available for older ACQUITY TUV detectors. New ACQUITY TUV detectors with serial number A10TUV001N or A10TUV001A and higher will have the intelligent chip technology available.

205015013 - ACQUITY TUV Flow Cell, 10nL, nano
Part Number: 205015013
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
nanoACQUITY
Products ACQUITY UPLC TUV Detector
nanoACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

205015016 - ACQUITY UPLC ID Cell TUV, Analytical

Part Number: 205015016

The ACQUITY UPLC Analytical Flowcell with Intelligent Chip Technology can be used in older detectors but the chip technology feature will not work with those older modules. Newer ACQUITY TUV models with serial number A10TUV001N or A10TUV001A will have the chip technology feature working in the detectors. This is the standard analytical flow cell in the ACQUITY TUV detectors.

205015016 - ACQUITY UPLC ID Cell TUV, Analytical
Part Number: 205015016
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

M960047DC1-S - Solids Probe Assembly

Part Number: M960047DC1-S

Solids Probe Assembly

M960047DC1-S - Solids Probe Assembly
Part Number: M960047DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
GCT Premier Mass Spectrometer
Replacement Schedule As Needed

info

205004340 - Flow Cell, 3mm Glassy Carbon, WE/Hy-REF

Part Number: 205004340

This spare part is a Waters Quality part.

205004340 - Flow Cell, 3mm Glassy Carbon, WE/Hy-REF
Part Number: 205004340
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

205015000 - Flowcell, Std, ACQUITY TUV

Part Number: 205015000

The Standard Flowcell is used for the ACQUITY UPLC TUV Detectors with serial numbers through K05UPT699N.

205015000 - Flowcell, Std, ACQUITY TUV
Part Number: 205015000
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

205015001 - Flowcell, Low Flow, ACQUITY TUV

Part Number: 205015001

The Low Flow Flowcell is used for the ACQUITY UPLC TUV Detectors with serial numbers through K05UPT699N.

205015001 - Flowcell, Low Flow, ACQUITY TUV
Part Number: 205015001
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

205015002 - Flow Cell, Std, ACQUITY PDA

Part Number: 205015002

The Standard Flowcell is used for the ACQUITY UPLC 2996 Detectors with Serial Numbers through K05UPD699N.

205015002 - Flow Cell, Std, ACQUITY PDA
Part Number: 205015002
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC 2996 PDA Detector
Replacement Schedule As Needed

info

205015003 - Flowcell, Low Flow, ACQUITY PDA

Part Number: 205015003

The Low Flow Flowcell is used for the ACQUITY UPLC 2996 Detectors with Serial Numbers through K05UPD699N

205015003 - Flowcell, Low Flow, ACQUITY PDA
Part Number: 205015003
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC 2996 PDA Detector
Replacement Schedule As Needed

info

186002479 - Bondapak C18 Prep Column, 125Å, 15-20 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002479

Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.

186002479 - Bondapak C18 Prep Column, 125Å, 15-20 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002479
Brand: Bondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 15-20 µm
Particle Substrate Silica
Pore Size 125Å
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

201000189 - GCT PREMIER FI/FD PERFORMANCE MAINTENANCE KIT

Part Number: 201000189

The Waters® Performance Maintenance Kit for the optional FI/FD on the GCT Premier Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your FI/FD source operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Field ionization/Field Desorption Source components.

201000189 - GCT PREMIER FI/FD PERFORMANCE MAINTENANCE KIT
Part Number: 201000189
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products GCT Premier Mass Spectrometer
Replacement Schedule As Needed

info

700000435 - 6 Column Select Valve

Part Number: 700000435

The 6-Column Selection Valve is a 6-position, 14-port valve. You can select one of 6 columns at a time, and you can dedicate one of the 6 column positions to bypass or waste. The 6-column selection valve requires two additional column clips to be installed. Slots are provided in the front of the column heater to hold tubing in place.

700000435 - 6 Column Select Valve
Part Number: 700000435
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

WAT035714 - Polyacrylic Acid Standards Kit

Part Number: WAT035714

A unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for aqueous molecular weight determination. These Polyacrylic Acid GPC standards cover a molecular weight range from 1,000 Daltons to 1,000,000 Daltons

WAT035714 - Polyacrylic Acid Standards Kit
Part Number: WAT035714
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System UPLC

info

201000150 - AUTOSPEC FAB PERFORMANCE MAINTENANCE KIT

Part Number: 201000150

The Waters® Performance Maintenance Kit for the optional FAB source found on Autospec Mass Spectrometers contains all the Waters Quality Parts® necessary to keep you operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: ceramics, spacers, insulators, o-rings, cesium source and other components to re-build the FAB Source.

201000150 - AUTOSPEC FAB PERFORMANCE MAINTENANCE KIT
Part Number: 201000150
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products AutoSpec Mass Spectrometer
AutoSpec Premier Mass Spectrometer
Replacement Schedule Annually

info

186007031 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186007031

Waters XSelect CSH130 C18 5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications

186007031 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186007031
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

176002744 - XEVO TQ-S (SCROLL) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002744

The Waters® Performance Maintenance Kit for the XEVO TQ-S (scroll) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source components, ESI probe components and vacuum pump components. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002744 - XEVO TQ-S (SCROLL) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002744
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Xevo TQ-S MS
Replacement Schedule Annually

info

176002745 - XEVO TQ-S (ROTARY) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002745

The Waters® Performance Maintenance Kit for the XEVO TQ-S (rotary) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source components, ESI probe components and vacuum pump components. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002745 - XEVO TQ-S (ROTARY) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002745
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Xevo TQ-S MS
Replacement Schedule Annually

info

M946438CC3-S - Source T-Wave

Part Number: M946438CC3-S

SOURCE ION GUIDE ASSEMBLY

M946438CC3-S - Source T-Wave
Part Number: M946438CC3-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products MALDI SYNAPT MS Mass Spectrometer
Q-Tof Premier MALDI Mass Spectrometer
Q-Tof Premier Mass Spectrometer
SYNAPT™ MS
Replacement Schedule As Needed

info

186001840 - Symmetry Shield RP18 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pkg

Part Number: 186001840

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.

186001840 - Symmetry Shield RP18 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pkg
Part Number: 186001840
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001846 - Symmetry Shield RP 8 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pkg

Part Number: 186001846

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

186001846 - Symmetry Shield RP 8 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pkg
Part Number: 186001846
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8