Product Listing:  186008325 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg   to   186008355 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg

Sorted by Popularity
  Product    
info

186008325 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg

Part Number: 186008325

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008325 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg
Part Number: 186008325
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008326 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186008326

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008326 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 186008326
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008327 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186008327

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008327 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186008327
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008328 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186008328

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008328 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186008328
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008329 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186008329

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008329 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186008329
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008330 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186008330

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008330 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186008330
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008331 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186008331

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008331 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186008331
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008332 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186008332

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008332 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186008332
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008333 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 30 mm, 3/pkg

Part Number: 186008333

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008333 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 30 mm, 3/pkg
Part Number: 186008333
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008334 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 50 mm, 3/pkg

Part Number: 186008334

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008334 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 50 mm, 3/pkg
Part Number: 186008334
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008335 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 75 mm, 3/pkg

Part Number: 186008335

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008335 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 75 mm, 3/pkg
Part Number: 186008335
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008336 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 100 mm, 3/pkg

Part Number: 186008336

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008336 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 100 mm, 3/pkg
Part Number: 186008336
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008337 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 150 mm, 3/pkg

Part Number: 186008337

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008337 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 150 mm, 3/pkg
Part Number: 186008337
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008338 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186008338

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008338 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186008338
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008339 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186008339

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008339 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186008339
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008340 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186008340

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008340 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186008340
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008342 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186008342

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008342 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186008342
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008343 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: 186008343

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008343 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: 186008343
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008344 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 50 mm, 3/pkg

Part Number: 186008344

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008344 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 50 mm, 3/pkg
Part Number: 186008344
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008345 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 75 mm, 3/pkg

Part Number: 186008345

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008345 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 75 mm, 3/pkg
Part Number: 186008345
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008346 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186008346

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008346 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186008346
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008347 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186008347

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008347 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186008347
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008348 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186008348

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008348 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186008348
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008349 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186008349

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008349 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186008349
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008350 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186008350

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008350 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186008350
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008351 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186008351

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008351 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186008351
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008352 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186008352

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008352 - CORTECS C8 Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186008352
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008353 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 30 mm, 3/pkg

Part Number: 186008353

CORTECS C8 method validation kits provide columns of three different batches. CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008353 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 30 mm, 3/pkg
Part Number: 186008353
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8

info

186008354 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 186008354

CORTECS C8 method validation kits provide columns of three different batches. CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008354 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 186008354
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8

info

186008355 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg

Part Number: 186008355

CORTECS C8 method validation kits provide columns of three different batches. CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008355 - CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg
Part Number: 186008355
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8