Product Listing:  186001945 - XTerra RP 8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg   to   205004330 - Flow Cell Kit, 3mm Ag WE. HyREF

Sorted by Popularity
  Product    
info

186001945 - XTerra RP 8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186001945

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186001945 - XTerra RP 8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186001945
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186003303 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003303

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186003303 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003303
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002474 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002474

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

186002474 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002474
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

700000289 - ESI Probe Assembly

Part Number: 700000289

This spare part is a Waters Quality part.

700000289 - ESI Probe Assembly
Part Number: 700000289
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
LCT Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule Annually

info

201000170 - QUATTRO MICRO GC PERFORMANCE MAINTENANCE KIT

Part Number: 201000170

The Waters® Performance Maintenance Kit for the Quattro micro GC Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance. The Waters® Performance Maintenance Kit includes the following parts: Source components and vacuum pump components.

201000170 - QUATTRO MICRO GC PERFORMANCE MAINTENANCE KIT
Part Number: 201000170
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule Annually

info

700005349 - Ion Block Assembly

Part Number: 700005349

Ion block assembly (does not include ion block support).

700005349 - Ion Block Assembly
Part Number: 700005349
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Xevo TQ-S MS
Replacement Schedule As Needed

info

186002757 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186002757

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002757 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186002757
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186004923 - Viridis Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186004923

Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as Viridis SFC 2-Ethylpyridine columns and Viridis SFC Silica columns. Larger preparative column formats are manufactured using Waters patented Optimum Bed Density (OBD) Technology. 2-Ethylpyridine chemistry is successfully used for a wide range of achiral SFC applications due to its retention, peak shape and selectivity properties. Viridis SFC 2-ethylpyridine columns also provide high reliability and reproducibility and can be used for analytical and preparative applications. Based on Waters long history of chromatographic silica production, the Viridis SFC Silica columns are designed to be highly reproducible and predictable based on tight product specifications and very low metal content.

186004923 - Viridis Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186004923
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System UPC2/SFC
Technology Silica
Units in Package 1/pkg

info

186004950 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186004950

Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as Viridis SFC 2-Ethylpyridine columns and Viridis SFC Silica columns. Larger preparative column formats are manufactured using Waters patented Optimum Bed Density (OBD) Technology. 2-Ethylpyridine chemistry is successfully used for a wide range of achiral SFC applications due to its retention, peak shape and selectivity properties. Viridis SFC 2-ethylpyridine columns also provide high reliability and reproducibility and can be used for analytical and preparative applications. Based on Waters long history of chromatographic silica production, the Viridis SFC Silica columns are designed to be highly reproducible and predictable based on tight product specifications and very low metal content.

186004950 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186004950
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 8
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 340
System UPC2/SFC
Technology Silica
Units in Package 1/pkg

info

700005530 - ESI Probe Assy.

Part Number: 700005530

The original part number was 279001231, but was changed to p/n 700005530.

700005530 - ESI Probe Assy.
Part Number: 700005530
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule As Needed

info

M960891DC1-S - CI Inner Source Assembly

Part Number: M960891DC1-S

CI Inner Source Assembly

M960891DC1-S - CI Inner Source Assembly
Part Number: M960891DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Premier Mass Spectrometer
Replacement Schedule As Needed

info

700000853 - Rheodyne Bypass/Inject Valve

Part Number: 700000853

The Rheodyne Bypass/Inject Valve has two functions. The bypass portion controls whether the solvent flows through the columns or bypasses the columns. The inject valve portion holds the sample and introduces it to the columns. This valve is located in the analysis compartment.

700000853 - Rheodyne Bypass/Inject Valve
Part Number: 700000853
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Systems
Replacement Schedule As Needed

info

700003110 - Quattro micro GC DCI Probe

Part Number: 700003110

This spare part is a Waters Quality part.

700003110 - Quattro micro GC DCI Probe
Part Number: 700003110
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed

info

176002060 - LCT PREMIER/XE (ROTARY) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002060

The Waters® Performance Maintenance Kit for the LCT Premier/XE (rotary) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components, reference probe components and vacuum pump components. The original part number was 201000171 and it has been changed to 176002060. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002060 - LCT PREMIER/XE (ROTARY) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002060
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Premier
LCT Premier XE
Replacement Schedule Annually

info

700003523 - Ion Block Assembly

Part Number: 700003523

This spare part is a Waters Quality part.

700003523 - Ion Block Assembly
Part Number: 700003523
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule As Needed

info

700003343 - Ion Block Assembly

Part Number: 700003343

Complete Ion Block Assembly.

700003343 - Ion Block Assembly
Part Number: 700003343
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products LCT Premier
Replacement Schedule As Needed

info

M702706CC1-S - Water Cooled Solids Probe

Part Number: M702706CC1-S

The Solids Probe is a direct introduction probe for the analysis of solid or low volatility liquid samples. The probe tip is water cooled to provide reduced analysis times and improved sample throughput. It is heatable from ambient temperature to 350°C. It uses the existing side entry probe vacuum lock and water cooling supplies.

M702706CC1-S - Water Cooled Solids Probe
Part Number: M702706CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products AutoSpec Mass Spectrometer
AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

186003437 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003437

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003437 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003437
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

205000500 - ACQUITY FLR Cell, Cuvette & Holder Kit

Part Number: 205000500

The cuvette cell option is useful for customers who perform method development with the Acquity FLR detector. The detector has a mode called Lambda/ Lambda where the customer can perform scans on a compound to determine where to set the excitation and emission wavelengths.

205000500 - ACQUITY FLR Cell, Cuvette & Holder Kit
Part Number: 205000500
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC Fluorescence Detector
Replacement Schedule As Needed

info

201000217 - LCT PREMIER/XE (ROTARY) PERFORMANCE MAINTENANCE KIT

Part Number: 201000217

The Waters® Performance Maintenance Kit for the LCT Premier/XE (rotary) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components, reference probe components and vacuum pump components. The original part number was 201000171. This particular part number does not deliver a chemical kit which is required to complete the performance testing. The part number for a Waters® Performance Maintenance Kit and a chemical kit is 176002060

201000217 - LCT PREMIER/XE (ROTARY) PERFORMANCE MAINTENANCE KIT
Part Number: 201000217
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Premier
LCT Premier XE
Replacement Schedule Annually

info

186003702 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003702

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003702 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003702
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002981 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186002981

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186002981 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186002981
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003269 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186003269

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186003269 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186003269
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186003961 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003961

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186003961 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003961
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

WAT054392 - Dextrans Standard

Part Number: WAT054392

A unique collection of 5 GPC standards (Gel Permeation Chromatography standards) for molecular weight determination. These Dextran GPC standards cover a molecular weight range from 5,000 Daltons to 750,000 Daltons

WAT054392 - Dextrans Standard
Part Number: WAT054392
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

205004215 - Flow Cell Kit, 2mm GC WE, ISAAC Ref.

Part Number: 205004215

The Flow Cell kit for the 2mm Glassy Carbon Working Electrode contains the following: (1) Flow Cell 2mm Glassy Carbon Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) ISAAC Reference electrode, 10mL ISAAC solution, (1) Hex Key, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, (1) MSDS for the Diamond Slurry solution, and (1) MSDS for the ISAAC Solution.

205004215 - Flow Cell Kit, 2mm GC WE, ISAAC Ref.
Part Number: 205004215
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

205004115 - Flow Cell Kit, 2mm GC WE, Salt Bridge

Part Number: 205004115

The Flow Cell kit for the 2mm Glassy Carbon Working Electrode contains the following: (1) Flow Cell 2mm Glassy Carbon Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) Salt Bridge Reference electrode, 50mL KCl solution, (1) Hex Key, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, (1) MSDS for the Diamond Slurry solution, and (1) MSDS for the KCl Solution.

205004115 - Flow Cell Kit, 2mm GC WE, Salt Bridge
Part Number: 205004115
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

205004220 - Flow Cell Kit, 3mm Pt WE, ISAAC Ref.

Part Number: 205004220

The Flow Cell kit for the 3mm Platinum Working Electrode contains the following: (1) Flow Cell 3mm Platinum Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) ISAAC Reference electrode, 10mL ISAAC solution, (1) Hex Key, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, (1) MSDS for the Diamond Slurry solution, and (1) MSDS for the ISAAC Solution.

205004220 - Flow Cell Kit, 3mm Pt WE, ISAAC Ref.
Part Number: 205004220
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

205004325 - Flow Cell Kit, 3mm AU WE, HyREF

Part Number: 205004325

The Flow Cell kit for the 3mm Gold Working Electrode contains the following: (1) Flow Cell 3mm Gold Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) Hex Key, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, and (1) MSDS for the Diamond Slurry solution.

205004325 - Flow Cell Kit, 3mm AU WE, HyREF
Part Number: 205004325
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

205004330 - Flow Cell Kit, 3mm Ag WE. HyREF

Part Number: 205004330

The Flow Cell kit for the 2mm Silver Working Electrode contains the following: (1) Flow Cell 2mm Silver Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) Hex Key, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, and (1) MSDS for the Diamond Slurry solution.

205004330 - Flow Cell Kit, 3mm Ag WE. HyREF
Part Number: 205004330
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed