Product Listing:  186007827 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg   to   186007883 - XSelect HSS T3 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Sorted by Popularity
  Product    
info

186007827 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007827

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 2.5 µm sorbent particles.

186007827 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007827
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007829 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007829

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 2.5 µm sorbent particles.

186007829 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007829
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007830 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007830

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 3.5 µm sorbent particles.

186007830 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007830
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007836 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007836

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 5 µm sorbent particles.

186007836 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007836
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007838 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007838

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 5 µm sorbent particles.

186007838 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007838
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007839 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007839

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 2.5 µm sorbent particles.

186007839 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007839
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007841 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007841

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 2.5 µm sorbent particles.

186007841 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007841
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007842 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007842

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 SB analytical columns containing 3.5 µm sorbent particles.

186007842 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007842
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007844 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007844

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 SB analytical columns containing 3.5 µm sorbent particles.

186007844 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007844
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007845 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007845

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 SB analytical columns containing 5 µm sorbent particles.

186007845 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007845
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007847 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007847

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 SB analytical columns containing 5 µm sorbent particles.

186007847 - XSelect HSS C18 SB VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007847
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007848 - XSelect HSS C18 SB XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007848

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 SB analytical columns containing 2.5 µm sorbent particles.

186007848 - XSelect HSS C18 SB XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007848
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007850 - XSelect HSS C18 SB XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007850

XSelect HSS C18 SB VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 SB analytical columns containing 2.5 µm sorbent particles.

186007850 - XSelect HSS C18 SB XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007850
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 8
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007851 - XSelect HSS C18 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007851

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 analytical columns containing 3.5 µm sorbent particles.

186007851 - XSelect HSS C18 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007851
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007853 - XSelect HSS C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007853

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 analytical columns containing 3.5 µm sorbent particles.

186007853 - XSelect HSS C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007853
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007854 - XSelect HSS C18 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007854

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 analytical columns containing 5 µm sorbent particles.

186007854 - XSelect HSS C18 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007854
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007856 - XSelect HSS C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007856

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 analytical columns containing 5 µm sorbent particles.

186007856 - XSelect HSS C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007856
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007857 - XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007857

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 analytical columns containing 2.5 µm sorbent particles.

186007857 - XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007857
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007859 - XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007859

XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS C18 analytical columns containing 2.5 µm sorbent particles.

186007859 - XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007859
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186007860 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007860

XSelect HSS CN VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS CN analytical columns containing 3.5 µm sorbent particles.

186007860 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007860
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L10
Units in Package 3/pkg
pH Range 2 - 8

info

186007862 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007862

XSelect HSS CN VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS CN analytical columns containing 3.5 µm sorbent particles.

186007862 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007862
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L10
Units in Package 3/pkg
pH Range 2 - 8

info

186007863 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007863

XSelect HSS CN VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS CN analytical columns containing 5 µm sorbent particles.

186007863 - XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007863
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L10
Units in Package 3/pkg
pH Range 2 - 8

info

186007872 - XSelect HSS PFP VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007872

XSelect HSS PFP VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS PFP analytical columns containing 5 µm sorbent particles.

186007872 - XSelect HSS PFP VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007872
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L43
Units in Package 3/pkg
pH Range 2 - 8

info

186007874 - XSelect HSS PFP VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007874

XSelect HSS PFP VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS PFP analytical columns containing 5 µm sorbent particles.

186007874 - XSelect HSS PFP VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007874
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L43
Units in Package 3/pkg
pH Range 2 - 8

info

186007875 - XSelect HSS PFP XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007875

XSelect HSS PFP VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS PFP analytical columns containing 2.5 µm sorbent particles.

186007875 - XSelect HSS PFP XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007875
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L43
Units in Package 3/pkg
pH Range 2 - 8

info

186007877 - XSelect HSS PFP XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007877

XSelect HSS PFP VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS PFP analytical columns containing 2.5 µm sorbent particles.

186007877 - XSelect HSS PFP XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007877
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System HPLC
Technology HSS
USP Classification L43
Units in Package 3/pkg
pH Range 2 - 8

info

186007878 - XSelect HSS T3 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007878

XSelect HSS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS T3 analytical columns containing 3.5 µm sorbent particles.

186007878 - XSelect HSS T3 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007878
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007880 - XSelect HSS T3 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007880

XSelect HSS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS T3 analytical columns containing 3.5 µm sorbent particles.

186007880 - XSelect HSS T3 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007880
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007881 - XSelect HSS T3 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007881

XSelect HSS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS T3 analytical columns containing 5 µm sorbent particles.

186007881 - XSelect HSS T3 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007881
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007883 - XSelect HSS T3 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007883

XSelect HSS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS T3 analytical columns containing 5 µm sorbent particles.

186007883 - XSelect HSS T3 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007883
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8