Product Listing:  186007792 - XBridge BEH HILIC XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg   to   186007841 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Sorted by Popularity
  Product    
info

186007792 - XBridge BEH HILIC XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007792

XBridge BEH HILIC VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH HILIC analytical columns containing 2.5 µm sorbent particles.

186007792 - XBridge BEH HILIC XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007792
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 9

info

186007793 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007793

XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Phenyl analytical columns containing 3.5 µm sorbent particles.

186007793 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007793
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

186007795 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007795

XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Phenyl analytical columns containing 3.5 µm sorbent particles.

186007795 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007795
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

186007796 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007796

XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Phenyl analytical columns containing 5 µm sorbent particles.

186007796 - XBridge BEH Phenyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007796
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

186007799 - XBridge BEH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007799

XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Phenyl analytical columns containing 2.5 µm sorbent particles.

186007799 - XBridge BEH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007799
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

186007801 - XBridge BEH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007801

XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Phenyl analytical columns containing 2.5 µm sorbent particles.

186007801 - XBridge BEH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007801
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

186007802 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007802

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 3.5 µm sorbent particles.

186007802 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007802
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007804 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007804

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 3.5 µm sorbent particles.

186007804 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007804
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007805 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007805

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 5 µm sorbent particles.

186007805 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007805
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007807 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007807

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 5 µm sorbent particles.

186007807 - XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007807
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007808 - XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007808

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 2.5 µm sorbent particles.

186007808 - XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007808
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007810 - XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007810

XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 2.5 µm sorbent particles.

186007810 - XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007810
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186007811 - XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007811

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH C18 analytical columns containing 3.5 µm sorbent particles.

186007811 - XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007811
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007813 - XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007813

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH C18 analytical columns containing 3.5 µm sorbent particles.

186007813 - XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007813
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007814 - XSelect CSH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007814

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH C18 analytical columns containing 5 µm sorbent particles.

186007814 - XSelect CSH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007814
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007816 - XSelect CSH C18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007816

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH C18 analytical columns containing 5 µm sorbent particles.

186007816 - XSelect CSH C18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007816
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007817 - XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007817

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH C18 analytical columns containing 2.5 µm sorbent particles.

186007817 - XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007817
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007819 - XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007819

XSelect CSH C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH C18 analytical columns containing 2.5 µm sorbent particles.

186007819 - XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007819
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186007820 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007820

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 3.5 µm sorbent particles.

186007820 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007820
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007822 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007822

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 3.5 µm sorbent particles.

186007822 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007822
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007824 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007824

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 5 µm sorbent particles.

186007824 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007824
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007826 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007826

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 5 µm sorbent particles.

186007826 - XSelect CSH Fluoro Phenyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007826
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007827 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007827

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 2.5 µm sorbent particles.

186007827 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007827
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007829 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007829

XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 2.5 µm sorbent particles.

186007829 - XSelect CSH Fluoro Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007829
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 3/pkg
pH Range 1 - 8

info

186007830 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007830

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 3.5 µm sorbent particles.

186007830 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007830
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007832 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007832

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 3.5 µm sorbent particles.

186007832 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007832
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007836 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007836

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 5 µm sorbent particles.

186007836 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007836
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007838 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007838

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 5 µm sorbent particles.

186007838 - XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007838
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007839 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007839

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 2.5 µm sorbent particles.

186007839 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007839
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

186007841 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007841

XSelect CSH Phenyl-Hexyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect CSH Phenyl-Hexyl analytical columns containing 2.5 µm sorbent particles.

186007841 - XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007841
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format XP VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11