Product Listing:  186003930 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 100 mm, 1/pkg   to   186001944 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg

Sorted by Popularity
  Product    
info

186003930 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003930

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003930 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003930
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT011805 - DeltaPak C18 Prep Column, 300Å, 15 µm, 30 mm X 300 mm, 1/pkg

Part Number: WAT011805

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT011805 - DeltaPak C18 Prep Column, 300Å, 15 µm, 30 mm X 300 mm, 1/pkg
Part Number: WAT011805
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 6.8
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 15 µm
Particle Substrate Silica
Pore Size 300Å
Surface Area 125
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011810 - DeltaPak C4 Prep Column, 100Å, 15 µm, 30 mm X 300 mm, 1/pkg

Part Number: WAT011810

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT011810 - DeltaPak C4 Prep Column, 100Å, 15 µm, 30 mm X 300 mm, 1/pkg
Part Number: WAT011810
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 7.3
Application Protein
Chemistry C4
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 15 µm
Particle Substrate Silica
Pore Size 100Å
Surface Area 300
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011815 - DeltaPak C4 Prep Column, 300Å, 15 µm, 30 mm X 300 mm, 1/pkg

Part Number: WAT011815

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT011815 - DeltaPak C4 Prep Column, 300Å, 15 µm, 30 mm X 300 mm, 1/pkg
Part Number: WAT011815
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 2.6
Application Protein
Chemistry C4
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 15 µm
Particle Substrate Silica
Pore Size 300Å
Surface Area 125
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 8

info

176002983 - UPLC AAA H-Class Applications Kit

Part Number: 176002983

UPLC AAA H-Class Applications Kit, Includes 186000384C Total Recovery Vials with caps, 186003836 AccQ-Tag Ultra™ Derivitization Kit , 186003837 AccQ-Tag Ultra™ C18 1.7µm 2.1x100mm Column, 186003838 AccQ-Tag Ultra™ Eluent A 1 Liter Bottle, 186003839 AccQ-Tag Ultra™ Eluent B 1 Liter Bottle, 430001783 Assy, Tube Inlet .0025 ID PEEK Nut PDA, 205000343 Column in-line filter kit, 716003230 Information Set, UPLC AAA H-Class Solution

176002983 - UPLC AAA H-Class Applications Kit
Part Number: 176002983
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System UPLC

info

WAT089592 - PrepPak® 1000 Module

Part Number: WAT089592

This spare part is a Waters Quality part

WAT089592 - PrepPak® 1000 Module
Part Number: WAT089592
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

This spare part is a Waters Quality part

info

186003439 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186003439

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003439 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186003439
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186003450 - SunFire Silica OBD Prep Column, 100Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186003450

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003450 - SunFire Silica OBD Prep Column, 100Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186003450
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186004083 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186004083

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186004083 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186004083
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

M946694CC1 - Inner Source Assembly, EI-GC

Part Number: M946694CC1

This spare part is a Waters Quality part

M946694CC1 - Inner Source Assembly, EI-GC
Part Number: M946694CC1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed

info

WAT036575 - Sep-Pak C18 Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 2000/pk

Part Number: WAT036575

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT036575 - Sep-Pak C18 Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 2000/pk
Part Number: WAT036575
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type Plus Short Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 2000/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT036955 - Sep-Pak Florisil Plus Long Cartridge, 910 mg Sorbent per Cartridge, 50-200 µm Particle Size, 2000/pk

Part Number: WAT036955

Polar, highly active, weakly basic sorbent for adsorption of low to moderate polarity species from nonaqueous solutions.

WAT036955 - Sep-Pak Florisil Plus Long Cartridge, 910 mg Sorbent per Cartridge, 50-200 µm Particle Size, 2000/pk
Part Number: WAT036955
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Florisil
Format/Type Plus Long Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Normal-phase
Particle Size 50-200 µm
Pore Size 60Å
Sorbent Substrate Florisil
Sorbent Weight 910 mg
Units In Package 2000/pkg
Water Wettable Water Wettable

info

186003279 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186003279

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003279 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186003279
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186005425 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005425

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005425 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005425
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005438 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005438

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005438 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005438
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005451 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005451

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005451 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005451
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005706

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005706
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005737 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005737

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005737 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005737
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005768 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005768

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005768 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005768
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186007298 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186007298

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186007298 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186007298
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

M805793CC1-S - Inner Source Low EV EI

Part Number: M805793CC1-S

This spare part is a Waters Quality part

M805793CC1-S - Inner Source Low EV EI
Part Number: M805793CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

201000147 - GCT PERFORMANCE MAINTENANCE KIT

Part Number: 201000147

The Waters® Performance Maintenance Kit for the GCT Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source components and vacuum pump components.

201000147 - GCT PERFORMANCE MAINTENANCE KIT
Part Number: 201000147
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
Replacement Schedule Annually

info

176002061 - LCT PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT

Part Number: 176002061

The Waters® Performance Maintenance Kit for the LCT Premier/XE (scroll) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components, reference probe components and vacuum pump components. The original part number was 201000191 and it has been changed to 176002061. This particular part number also delivers a chemical kit which is required to complete the performance testing.

176002061 - LCT PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT WITH CHEMICAL KIT
Part Number: 176002061
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Premier
LCT Premier XE
Replacement Schedule Annually

info

M805729CC1-S - Cold Probe Assembly

Part Number: M805729CC1-S

This spare part is a Waters Quality part

M805729CC1-S - Cold Probe Assembly
Part Number: M805729CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

186002173 - BioSuite SEC Column, 450Å, 17 µm, 21.5 mm X 300 mm, 20K - 7M, 1/pkg

Part Number: 186002173

BioSuite SEC Columns are available in 4.6 mm, 7.5 mm, and 7.8 mm i.d. analytical and 21.5 mm i.d. preparative and guard columns.

186002173 - BioSuite SEC Column, 450Å, 17 µm, 21.5 mm X 300 mm, 20K - 7M, 1/pkg
Part Number: 186002173
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Protein
Chemistry SEC
Endfitting Type Parker-style
Format Column
ID 21.5 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 20K - 7M
Particle Shape Spherical
Particle Size (dp) 17 µm
Particle Substrate Silica
Pore Size 450Å
System HPLC
USP Classification L59
Units in Package 1/pkg
pH Range 2.5 - 7.5

info

186002169 - BioSuite SEC Column, 125Å, 13 µm, 21.5 mm X 300 mm, 1/pkg

Part Number: 186002169

BioSuite SEC Columns are available in 4.6 mm, 7.5 mm, and 7.8 mm i.d. analytical and 21.5 mm i.d. preparative and guard columns.

186002169 - BioSuite SEC Column, 125Å, 13 µm, 21.5 mm X 300 mm, 1/pkg
Part Number: 186002169
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry SEC
Endfitting Type Parker-style
Format Column
ID 21.5 mm
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 13 µm
Particle Substrate Silica
Pore Size 125Å
System HPLC
USP Classification L59
Units in Package 1/pkg
pH Range 2.5 - 7.5

info

186002171 - BioSuite SEC Column, 250Å, 13 µm, 21.5 mm X 300 mm, 10K - 500K, 1/pkg

Part Number: 186002171

BioSuite SEC Columns are available in 4.6 mm, 7.5 mm, and 7.8 mm i.d. analytical and 21.5 mm i.d. preparative and guard columns.

186002171 - BioSuite SEC Column, 250Å, 13 µm, 21.5 mm X 300 mm, 10K - 500K, 1/pkg
Part Number: 186002171
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Protein
Chemistry SEC
Endfitting Type Parker-style
Format Column
ID 21.5 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 13 µm
Particle Substrate Silica
Pore Size 250Å
System HPLC
USP Classification L59
Units in Package 1/pkg
pH Range 2.5 - 7.5

info

201000218 - LCT PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT

Part Number: 201000218

The Waters® Performance Maintenance Kit for the LCT Premier/XE (scroll) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components, reference probe components and vacuum pump components. The original part number was 201000191. This particular part number does not deliver a chemical kit which is required to complete the performance testing. The part number for a Waters® Performance Maintenance Kit and a chemical kit is 176002061

201000218 - LCT PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT
Part Number: 201000218
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products LCT Premier
LCT Premier XE
Replacement Schedule Annually

info

186001943 - XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186001943

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186001943 - XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186001943
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186001944 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186001944

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186001944 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186001944
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12