Product Listing:  186007301 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg   to   700000436 - Probe Adjuster Assembly (LCZ/ZMD/Ultima)

Sorted by Popularity
  Product    
info

186007301 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186007301

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186007301 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186007301
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186002765 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002765

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002765 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002765
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186002795 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002795

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002795 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002795
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186003438 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003438

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003438 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003438
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186003711 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003711

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003711 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003711
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700004475 - AutoSpec Source Focus Lens Assembly

Part Number: 700004475

The original part number was M802345CC1, but was changed to p/n 700004475.

700004475 - AutoSpec Source Focus Lens Assembly
Part Number: 700004475
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

186002473 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002473

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

186002473 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002473
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700002970 - Inner Source Assembly, ESI Probe

Part Number: 700002970

The original part number was M946696CC1 and in Jan. 2007 it was changed to 700002970.

700002970 - Inner Source Assembly, ESI Probe
Part Number: 700002970
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Replacement Schedule As Needed

info

186004951 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186004951

Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as Viridis SFC 2-Ethylpyridine columns and Viridis SFC Silica columns. Larger preparative column formats are manufactured using Waters patented Optimum Bed Density (OBD) Technology. 2-Ethylpyridine chemistry is successfully used for a wide range of achiral SFC applications due to its retention, peak shape and selectivity properties. Viridis SFC 2-ethylpyridine columns also provide high reliability and reproducibility and can be used for analytical and preparative applications. Based on Waters long history of chromatographic silica production, the Viridis SFC Silica columns are designed to be highly reproducible and predictable based on tight product specifications and very low metal content.

186004951 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186004951
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 8
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 340
System UPC2/SFC
Technology Silica
Units in Package 1/pkg

info

M946130CC1-S - Focus Plate Assembly

Part Number: M946130CC1-S

This spare part is a Waters Quality part.

M946130CC1-S - Focus Plate Assembly
Part Number: M946130CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed

info

186002801 - Atlantis dc18 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002801

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186002801 - Atlantis dc18 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002801
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186003703 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003703

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003703 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003703
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010640 - Protein-Pak DEAE 5PW Column, 12.5 µm, 21.5x150 mm, 1/pkg

Part Number: WAT010640

10 µm polymer based ion-exchanger.

WAT010640 - Protein-Pak DEAE 5PW Column, 12.5 µm, 21.5x150 mm, 1/pkg
Part Number: WAT010640
Brand: Protein-Pak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Protein-Pak Columns
Application Peptide
Protein
Chemistry Anion-exchange
Format Column
ID 21.5 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 12.5 µm
Particle Substrate Polymer
Pore Size 1000Å
USP Classification L23
Units in Package 1/pkg
pH Range 2 - 12

info

186003661 - XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003661

The XBridge BEH130 C18 Peptide Separation Technology (PST) preparative columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis. The Optimum Bed Denisity (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003661 - XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003661
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
Application Peptide
Chemistry C18
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Pore Size 130Å
QC Tested Peptide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186003676 - XBridge Peptide BEH C18 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003676

The XBridge BEH300 C18 Peptide Separation Technology (PST) preparative columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis. The Optimum Bed Denisity (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003676 - XBridge Peptide BEH C18 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003676
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 12
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003962

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003962
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186007319 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186007319

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007319 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186007319
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

186007339 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186007339

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007339 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186007339
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

201000188 - GCT PREMIER PERFORMANCE MAINTENANCE KIT

Part Number: 201000188

The Waters® Performance Maintenance Kit for the GCT Premier Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit for the GCT Premier Mass Spectrometer includes the following parts: Source components and vacuum pump components.

201000188 - GCT PREMIER PERFORMANCE MAINTENANCE KIT
Part Number: 201000188
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products GCT Premier Mass Spectrometer
Replacement Schedule Annually

info

186004952 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186004952

Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as Viridis SFC 2-Ethylpyridine columns and Viridis SFC Silica columns. Larger preparative column formats are manufactured using Waters patented Optimum Bed Density (OBD) Technology. 2-Ethylpyridine chemistry is successfully used for a wide range of achiral SFC applications due to its retention, peak shape and selectivity properties. Viridis SFC 2-ethylpyridine columns also provide high reliability and reproducibility and can be used for analytical and preparative applications. Based on Waters long history of chromatographic silica production, the Viridis SFC Silica columns are designed to be highly reproducible and predictable based on tight product specifications and very low metal content.

186004952 - Viridis Silica 2-Ethylpyridine OBD Prep Column, 100Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186004952
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 8
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 340
System UPC2/SFC
Technology Silica
Units in Package 1/pkg

info

186003898 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186003898

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003898 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186003898
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003998 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186003998

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003998 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186003998
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186004013 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186004013

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186004013 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186004013
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

700004254 - ESI Probe Assembly

Part Number: 700004254

This spare part is a Waters Quality part.

700004254 - ESI Probe Assembly
Part Number: 700004254
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Xevo Q-Tof Mass Spec
Xevo™ TQ MS
Replacement Schedule As Needed

info

WAT025877 - Porasil Silica Radial-Pak Cartridge, 125Å, 40 µm, 47 mm X 50 mm, 10/pkg

Part Number: WAT025877

Waters Porasil 15 - 20µm silica packing material provides long column life and low backpressure. The packing also has a high surface area making it ideal for preparative work.

WAT025877 - Porasil Silica Radial-Pak Cartridge, 125Å, 40 µm, 47 mm X 50 mm, 10/pkg
Part Number: WAT025877
Brand: Porasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Radial-Pak Cartridge
ID 47 mm
Length (mm) 50 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 40 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 10/pkg
pH Range 2 - 8

info

186002844 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186002844

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002844 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186002844
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

M960031CC1-S - GC Interface Assembly (GCT)

Part Number: M960031CC1-S

GC Interface Assembly (GCT)

M960031CC1-S - GC Interface Assembly (GCT)
Part Number: M960031CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
Replacement Schedule As Needed

info

M802351CC1 - Lock and Probe Assembly (Front)

Part Number: M802351CC1

This spare part is a Waters Quality part.

M802351CC1 - Lock and Probe Assembly (Front)
Part Number: M802351CC1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

205004100 - Flow Cell Kit, 0.7mm GC WE, Salt Bridge

Part Number: 205004100

The Flow Cell kit for the 0.7mm Glassy Carbon Working Electrode contains the following: (1) Micro Flow Cell 0.7mm Glassy Carbon Working Electrode. (4) Flow cell finger tight fittings, (2) 120µm spacers, (2) 25µm spacers, (4) 50µm spacers, (1) polishing disk for the working electrode, 10mL 1µm Diamond Slurry, (1) Salt Bridge Reference electrode, 50mL KCl solution, (1) Hex Key, (1) Capillary Connections Kit, (1) Polishing disk for the reference electrode, PEEK Inlet Tubing 0.01in. ID x 20cm, PEEK Outlet Tubing 0.02in. ID x 1m, (1) MSDS for the Diamond Slurry solution, and (1) MSDS for the KCl Solution.

205004100 - Flow Cell Kit, 0.7mm GC WE, Salt Bridge
Part Number: 205004100
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

700000436 - Probe Adjuster Assembly (LCZ/ZMD/Ultima)

Part Number: 700000436

This spare part is a Waters Quality part.

700000436 - Probe Adjuster Assembly (LCZ/ZMD/Ultima)
Part Number: 700000436
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Q-Tof micro Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed