Product Listing:  186003083 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg   to   186005771 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Sorted by Popularity
  Product    
info

186003083 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003083

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186003083 - XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003083
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186003284 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003284

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003284 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003284
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003896 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003896

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003896 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003896
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003996 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003996

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003996 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003996
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186004011 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186004011

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186004011 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186004011
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186007030 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186007030

Waters XSelect CSH130 C18 5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications

186007030 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186007030
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

M805789DC1-S - Outer Ion Chamber Assembly

Part Number: M805789DC1-S

The Outer Ion Chamber Assembly is a replacement spare part for the AutoSpec Premier Mass Spectometer.

M805789DC1-S - Outer Ion Chamber Assembly
Part Number: M805789DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info

186003276 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003276

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003276 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003276
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186005426 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186005426

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005426 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186005426
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005439 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186005439

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005439 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186005439
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005452 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186005452

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005452 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186005452
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005769 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186005769

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005769 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186005769
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186007299 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186007299

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186007299 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186007299
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

M961012CC1-S - Insertion Lock Assembly

Part Number: M961012CC1-S

The original part number was M960045CC3 and in Jan. 2007, it was changed to M961012CC1-S.

M961012CC1-S - Insertion Lock Assembly
Part Number: M961012CC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed

info

M956315DC1 - ESI Probe Assembly

Part Number: M956315DC1

ESI Probe Assembly

M956315DC1 - ESI Probe Assembly
Part Number: M956315DC1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Replacement Schedule As Needed

info

186004732 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186004732

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004732 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186004732
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

700003111 - Quattro micro GC Solids Probe

Part Number: 700003111

This spare part is a Waters Quality part.

700003111 - Quattro micro GC Solids Probe
Part Number: 700003111
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed

info

186003933 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186003933

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003933 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186003933
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002267 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002267

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002267 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002267
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002268 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002268

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002268 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002268
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002269 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002269

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002269 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002269
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002270 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002270

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002270 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002270
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

M956079DC1-S - IonSabre/APcI Probe Assembly

Part Number: M956079DC1-S

The probe is available as a replacement spare for the instruments listed in the Specifications section and is also suitable for the initial purchase of the IonSabre capability for Quattro Ultima PT instruments only. All other instruments require an additional power supply, which is included in the IonSabre accessory upgrade products.

M956079DC1-S - IonSabre/APcI Probe Assembly
Part Number: M956079DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category MS Accessories
Mass Spectrometry
Products Ion Sabre Option
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof micro Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Replacement Schedule As Needed

info

700000290 - ApCI Probe Assembly

Part Number: 700000290

An atmospheric pressure chemical ionization(APCI) probe introduces the sample to the ion source. The original part number was 725000214. The part number has been changed to p/n 700000290.

700000290 - ApCI Probe Assembly
Part Number: 700000290
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule Annually

info

M956335DC1 - APcI IonSabre Probe Assembly

Part Number: M956335DC1

The APcI IonSabre Probe is used with the Quattro Premier/XE Mass Spectrometer, both as a spare and for the initial purchase of IonSabre APcI capability.

M956335DC1 - APcI IonSabre Probe Assembly
Part Number: M956335DC1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category MS Accessories
Mass Spectrometry
Products Ion Sabre Option
Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Replacement Schedule As Needed

info

186005494 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005494

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005494 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005494
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005508 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005508

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005508 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005508
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005709

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005709
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005740 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005740

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005740 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005740
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005771 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005771

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005771 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005771
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg