Product Listing:  186003662 - XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg   to   186002990 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Sorted by Popularity
  Product    
info

186003662 - XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186003662

The XBridge BEH130 C18 Peptide Separation Technology (PST) preparative columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis. The Optimum Bed Denisity (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003662 - XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186003662
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186007320 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186007320

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007320 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186007320
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

186007340 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186007340

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007340 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186007340
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

700005458 - Intermediate Housing Lid Assy.

Part Number: 700005458

The Intermediate Housing Lid Assembly is found on the MALDI SYNAPT G2 and SYNAPT GS-S HDMS/MS Systems.

700005458 - Intermediate Housing Lid Assy.
Part Number: 700005458
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
SYNAPT G2-S
Replacement Schedule As Needed

info

186004733 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186004733

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004733 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186004733
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186002223 - XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002223

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002223 - XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002223
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002224 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002224

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002224 - XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002224
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002225 - XTerra RP 8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002225

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002225 - XTerra RP 8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002225
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186003939 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186003939

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003939 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186003939
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003940 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186003940

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003940 - XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186003940
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186003902 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186003902

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003902 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186003902
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003999 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186003999

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003999 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186003999
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186004014 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186004014

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186004014 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186004014
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002870 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002870

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002870 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002870
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186005495 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186005495

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005495 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186005495
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005509 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186005509

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005509 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186005509
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005741 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186005741

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005741 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186005741
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005772 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186005772

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005772 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186005772
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186007302 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186007302

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186007302 - XSelect CSH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186007302
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

176002472 - ASAP Accessory, Synapt G2-Si, Xevo G2 (-S/XS) Tof/G2(-S/XS) QTof

Part Number: 176002472

The Atmospheric Solids Analysis Probe (ASAP) is a useful tool for the rapid direct analysis of volatile and semi-volatile, solid and liquid samples using atmospheric pressure ionization. The probe is user installable. No additional software is required.

176002472 - ASAP Accessory, Synapt G2-Si, Xevo G2 (-S/XS) Tof/G2(-S/XS) QTof
Part Number: 176002472
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products SYNAPT G2-Si
Xevo G2 Q-Tof Mass Spec
Xevo G2 TOF Mass Spec
Xevo G2-S QTof
Xevo G2-S Tof
Xevo G2-XS QTof
Xevo G2-XS Tof
Replacement Schedule No

info

176002049 - ASAP Accessory, SQD/TQD

Part Number: 176002049

The Atmospheric Solids Analysis Probe (ASAP) is a useful tool for the rapid direct analysis of volatile and semi-volatile, solid and liquid samples using atmospheric pressure ionization. The probe is user installable. No additional software is required.

176002049 - ASAP Accessory, SQD/TQD
Part Number: 176002049
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products 3100 Mass Detector
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule As Needed

info

186003440 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186003440

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003440 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186003440
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186004081 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186004081

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186004081 - Atlantis T3 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186004081
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004084 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186004084

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186004084 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186004084
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011801 - DeltaPak C18 Prep Column, 100Å, 15 µm, 50 mm X 300 mm, 1/pkg

Part Number: WAT011801

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT011801 - DeltaPak C18 Prep Column, 100Å, 15 µm, 50 mm X 300 mm, 1/pkg
Part Number: WAT011801
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 50 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 15 µm
Particle Substrate Silica
Pore Size 100Å
Surface Area 300
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002222 - XTerra MS C18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg

Part Number: 186002222

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002222 - XTerra MS C18 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pkg
Part Number: 186002222
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002846 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186002846

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002846 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186002846
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

725000177 - Peltier Cooled 6 DW Stack

Part Number: 725000177

The Peltier cooled 6DW Stack, (4°C to 40°C) holds (6) standard microtiter plates or (6) deepwell plates, or (6) PAL 2mLstandard trays and includes (1) 110V/220V Power Supply, LED Display, and temperature regulation ± 1°C.

725000177 - Peltier Cooled 6 DW Stack
Part Number: 725000177
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Injectors
Products 2777 Compact Sample Manager
2777 Sample Manager
Replacement Schedule As Needed

info

186004729 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186004729

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004729 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186004729
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186002990 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186002990

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002990 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186002990
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11