Product Listing:  186004002 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg   to   186003897 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg

Sorted by Popularity
  Product    
info

186004002 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186004002

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186004002 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186004002
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186004016 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186004016

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186004016 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186004016
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186005497 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186005497

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005497 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186005497
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005511 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186005511

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005511 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186005511
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005743 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186005743

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005743 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186005743
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005774 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186005774

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005774 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186005774
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186002847 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186002847

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002847 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186002847
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002850 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186002850

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002850 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186002850
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

M960022DC1-S - Outer Source Assembly (GCT)

Part Number: M960022DC1-S

Outer Source Assembly (GCT)

M960022DC1-S - Outer Source Assembly (GCT)
Part Number: M960022DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
Replacement Schedule As Needed

info

186002768 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186002768

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002768 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186002768
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186003452 - SunFire Silica OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186003452

SunFire Prep OBD Silica columns are preparative columns used under normal phase conditions. The Optimum Bed Density (OBD) hardware format ensures superior column lifetime under a wide variety of operating conditions.

186003452 - SunFire Silica OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186003452
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186004086 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186004086

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186004086 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186004086
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007028 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186007028

Waters XSelect CSH130 C18 5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications

186007028 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186007028
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186004734 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186004734

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004734 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186004734
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186007024 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186007024

Waters XSelect CSH130 C18 5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications

186007024 - XSelect Peptide CSH C18 OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186007024
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186003899 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186003899

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003899 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186003899
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004001 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186004001

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186004001 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186004001
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186004015 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186004015

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186004015 - XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186004015
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002275 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002275

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002275 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002275
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002276 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002276

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002276 - XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002276
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186002277 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002277

XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002277 - XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002277
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002278 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg

Part Number: 186002278

XTerra Preparative RP8 columns are hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186002278 - XTerra RP 8 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pkg
Part Number: 186002278
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186004731 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186004731

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004731 - XBridge BEH HILIC OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186004731
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186005496 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005496

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005496 - XSelect CSH C18 OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005496
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186005503 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005503

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005503 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005503
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005510 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005510

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005510 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005510
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005742 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005742

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005742 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005742
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005773 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005773

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005773 - Viridis BEH 2-Ethylpyridine OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005773
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

M951437DC1-S - Nanoflow Adjuster Assembly

Part Number: M951437DC1-S

This spare part is part of the NanoLockspray Option.

M951437DC1-S - Nanoflow Adjuster Assembly
Part Number: M951437DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products Q-Tof Premier Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

186003897 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186003897

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003897 - XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186003897
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12