Product Listing:  186005755 - Viridis BEH 2-Ethylpyridine Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg   to   186003114 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 75 mm, 1/pkg

Sorted by Popularity
  Product    
info

186005755 - Viridis BEH 2-Ethylpyridine Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186005755

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005755 - Viridis BEH 2-Ethylpyridine Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186005755
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

WAT056920 - Nova-Pak Cyano (CN) Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT056920

Nova-Pak HP CN columns are silica-based, cyano phases that are based on 4 µm particle technology. These columns can be used to achieve unique compound selectivity for both normal-phase and reversed-phase applications.

WAT056920 - Nova-Pak Cyano (CN) Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT056920
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3
Chemistry Cyano (CN)
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

186006072 - XBridge BEH Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006072

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006072 - XBridge BEH Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006072
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186006096 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006096

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006096 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006096
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

PSS833433 - Spherisorb ODS1 Column, 80Å, 3 µm, 1 mm X 150 mm, 1/pkg

Part Number: PSS833433

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS833433 - Spherisorb ODS1 Column, 80Å, 3 µm, 1 mm X 150 mm, 1/pkg
Part Number: PSS833433
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000525 - XTerra RP 8 Cartridge, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pkg

Part Number: 186000525

XTerra RP8 columns are general purpose, hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column. Please see the section below on related parts for more information

186000525 - XTerra RP 8 Cartridge, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pkg
Part Number: 186000525
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186000546 - XTerra MS C18 Cartridge, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186000546

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000546 - XTerra MS C18 Cartridge, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186000546
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000570 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000570

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000570 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000570
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000572 - XTerra Shield RP18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000572

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000572 - XTerra Shield RP18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000572
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186003453 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003453

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186003453 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003453
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format Prep Column
ID 4.6 mm
Length (mm) 150 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186006036 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006036

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006036 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006036
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186006048 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006048

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006048 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006048
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006060 - XBridge BEH Shield RP18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006060

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006060 - XBridge BEH Shield RP18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006060
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186006084 - XBridge BEH HILIC XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006084

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006084 - XBridge BEH HILIC XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006084
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 8

info

186006108 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006108

XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006108 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006108
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006120 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006120

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006120 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006120
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186006950 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006950

Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006950 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006950
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006955 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186006955

Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006955 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186006955
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186007364 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186007364

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007364 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186007364
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007369 - CORTECS C18 Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186007369

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007369 - CORTECS C18 Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186007369
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007374 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007374

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007374 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007374
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007379 - CORTECS HILIC Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186007379

CORTECS HILIC Columns are high-effiency columns based on a solid-core particle that are designed to retain extremely polar analytes. They offer orthogonal selectivity vs. C18 columns.

186007379 - CORTECS HILIC Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186007379
Brand: CORTECS

Products > Chromatography Consumables & Columns
Chemistry HILIC
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity High
Surface Area 100
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186007384 - CORTECS HILIC Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186007384

CORTECS HILIC Columns are high-effiency columns based on a solid-core particle that are designed to retain extremely polar analytes. They offer orthogonal selectivity vs. C18 columns.

186007384 - CORTECS HILIC Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186007384
Brand: CORTECS

Products > Chromatography Consumables & Columns
Chemistry HILIC
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity High
Surface Area 100
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186007389 - CORTECS HILIC Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007389

CORTECS HILIC Columns are high-effiency columns based on a solid-core particle that are designed to retain extremely polar analytes. They offer orthogonal selectivity vs. C18 columns.

186007389 - CORTECS HILIC Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007389
Brand: CORTECS

Products > Chromatography Consumables & Columns
Chemistry HILIC
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity High
Surface Area 100
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186007394 - CORTECS C18+ Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186007394

CORTECS C18+ columns are general purpose, charged surface, high efficiency C18 columns based on a solid-core particle that is designed to deliver excellent peak shape for basic analytes at low pH

186007394 - CORTECS C18+ Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186007394
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002031 - Atlantis Silica HILIC Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002031

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002031 - Atlantis Silica HILIC Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002031
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186004476 - Isolator Column

Part Number: 186004476

Designed to be used with Waters ACQUITY Application Specific Kits, the Isolator Column separates background contaminates from the sample to be analyzed, thus removing interferences and allowing for extremely low detection limits. Utilized for such applications as Perfluorinated Compounds (PFCs/PFOA/PFOS) and Bisphenol A the Isolator column features the same technological advances as the other columns in the ACQUITY UPLC product family and is designed, tested and certified to operate with ACQUITY UPLC Systems.

186004476 - Isolator Column
Part Number: 186004476
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Particle Shape Spherical
Particle Substrate Hybrid
Silanol Activity Low
System UPLC/UHPLC
Units in Package 1/pkg
pH Range 1 - 12

info

186003007 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186003007

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003007 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186003007
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003043 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186003043

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003043 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186003043
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003114 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186003114

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003114 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186003114
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12