Product Listing:  430001516 - Sample Loop, 1µL   to   430002153 - Tubing, Capillary w/Frit, 25µ x 12in.

Sorted by Category
  Product    
info

430001516 - Sample Loop, 1µL

Part Number: 430001516

ACQUITY SM Sample Loop, 1µL

430001516 - Sample Loop, 1µL
Part Number: 430001516
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001569 - Tube, Filter to Flow Sensor Inlet B

Part Number: 430001569

The tube from the filter to the flow sensor inlet B fits into the 10,000psi nanoACQUITY system.

430001569 - Tube, Filter to Flow Sensor Inlet B
Part Number: 430001569
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
Replacement Schedule As Needed

info

430001570 - Capillary Tubing w/frit, 25u X 10in

Part Number: 430001570

The capillary tubing with frit from the inject valve to nano tee fits into the 10,000psi nanoACQUITY system.

430001570 - Capillary Tubing w/frit, 25u X 10in
Part Number: 430001570
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001571 - Capillary Tubing w/frit, 40u X 16in

Part Number: 430001571

The capillary tubing with frit from the nano tee to the trap valve tube fits into the 10,000psi nanoACQUITY system. The configurations that this spare part can be found in are the following: Direct Injection, 2D with Dilution, Single Pump Trapping, and Vented Dual Pump Trapping. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430001571 - Capillary Tubing w/frit, 40u X 16in
Part Number: 430001571
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001572 - Tube, ASM to MS, 25µm x 60in.

Part Number: 430001572

The ASM to MS tube that is 25µm x 60in. fits into the 10,000psi nanoACQUITY System.

430001572 - Tube, ASM to MS, 25µm x 60in.
Part Number: 430001572
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
Replacement Schedule As Needed

info

430001575 - Cap. Tube Assy., BSM to Trap Valve

Part Number: 430001575

The 25um x 30in. Capillary Tubing connects the BSM to the trap valve of the nanoACQUITY UPLC system in a Dual Pump Trapping Configuration, a Vented Dual Pump Trapping Configuration, or a 2D Configuration. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430001575 - Cap. Tube Assy., BSM to Trap Valve
Part Number: 430001575
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001576 - 40um Capillary, ASM to Inject. Valve

Part Number: 430001576

The 40um Capillary from the ASM to the inject valve fits into the 10,000psi nanoACQUITY system.

430001576 - 40um Capillary, ASM to Inject. Valve
Part Number: 430001576
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001577 - Cap.Tubing Assy., Inj. Vlv to Trap Vlv

Part Number: 430001577

The Capillary Tubing Assembly from the Inject Valve to the Trap Valve is found in the 2D configuration of the nanoACQUITY UPLC. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430001577 - Cap.Tubing Assy., Inj. Vlv to Trap Vlv
Part Number: 430001577
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001629 - Cap.Tubing Assy., Inj. Vlv. to Trap Vlv.

Part Number: 430001629

This capillary tubing fits between the injector and the trap valve of the nanoACQUITY UPLC with dual pumps. It is used in the following configurations: Vented Dual Pump and Dual Pump Trapping configurations. The tubing measures 40µm by 13in.long. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430001629 - Cap.Tubing Assy., Inj. Vlv. to Trap Vlv.
Part Number: 430001629
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC with 2D Technology
Replacement Schedule As Needed

info

430001630 - 2695 Sample Loop, 200µL

Part Number: 430001630

This spare part is a Waters Quality part.

430001630 - 2695 Sample Loop, 200µL
Part Number: 430001630
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

430001715 - Post-heater Tube Set, .0025 ID

Part Number: 430001715

ACQUITY Column Heater Post-heater Tube Set, .0025 ID Tan PEEK

430001715 - Post-heater Tube Set, .0025 ID
Part Number: 430001715
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products Column Heater
Replacement Schedule As Needed

info

430001748 - ASSY, TUBE INLET .004 ID LT PEEK NUT

Part Number: 430001748

The Inlet Tube Assembly fits on ACQUITY UPLC TUV Detectors with serial numbers through K05UPT699N and with serial numbers from K05UPT700N and later.This part number has been changed to 430001748.

430001748 - ASSY, TUBE INLET .004 ID LT PEEK NUT
Part Number: 430001748
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY PDA (Taperslit) Detectors
ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

430001749 - ASSY, TUBE INLET .0025 ID LT PEEK NUT

Part Number: 430001749

The Inlet Tube Assembly fits on ACQUITY UPLC TUV Detectors with serial numbers through K05UPT699N and with serial numbers from K05UPT700N and later. This part number used to be 430001214.

430001749 - ASSY, TUBE INLET .0025 ID LT PEEK NUT
Part Number: 430001749
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY PDA (Taperslit) Detectors
ACQUITY UPLC TUV Detector
Replacement Schedule As Needed

info

430001773 - Tube Assy, Transducer to Check Vlv, I2V

Part Number: 430001773

This tube assembly from the Transducer to the check valve is part of the Intelligent Intake Valve found in the ACQUITY Binary Solvent Manager.

430001773 - Tube Assy, Transducer to Check Vlv, I2V
Part Number: 430001773
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC I2V Binary Solvent Manager
Replacement Schedule As Needed

info

430001784 - Inlet Tube Assembly

Part Number: 430001784

The original part number was p/n 430001226 and has been changed to p/n 430001784.

430001784 - Inlet Tube Assembly
Part Number: 430001784
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC PDA Detector
ACQUITY UPLC eLAmbda PDA Detector
Replacement Schedule As Needed

info

430001835 - Tubing, Capillary w/frit 75µm x 8in.

Part Number: 430001835

The part number 430001835, Capillary Tubing, with frit, 75µm x 8 inches is part of the Mixer Kit for 1mm Columns (part number 205000540).

430001835 - Tubing, Capillary w/frit 75µm x 8in.
Part Number: 430001835
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001837 - Tubing, Capillary w/frit, 75µm x 10in.

Part Number: 430001837

The part number 430001837, Capillary Tubing, with frit, 75µm x 10inches is part of the Mixer Kit for 1mm Columns (part number 205000540).

430001837 - Tubing, Capillary w/frit, 75µm x 10in.
Part Number: 430001837
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001848 - Tubing, Capillary, 300µm Column Outlet

Part Number: 430001848

The part number 430001848, Capillary Tubing, 300µm Column Oultet is part of the Mixer Kit for 1mm Columns (part number 205000540).

430001848 - Tubing, Capillary, 300µm Column Outlet
Part Number: 430001848
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430001893 - Tube Assy, Vent Valve Port 1 to Waste

Part Number: 430001893

ACQUITY BSM Tube Assy, Vent Valve Port 1 to Waste .010 ID

430001893 - Tube Assy, Vent Valve Port 1 to Waste
Part Number: 430001893
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

430001894 - Tube Assy, Vent Valve Port 4 to Waste

Part Number: 430001894

ACQUITY BSM Tube Assy, Vent Valve Port 4 to Waste .010 ID

430001894 - Tube Assy, Vent Valve Port 4 to Waste
Part Number: 430001894
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

430001919 - Tubing, HPLC Post Column, .005ID

Part Number: 430001919

HPLC Post Column Tubing, .005ID x 35 long for ACQUITY 30cm Column Heater/Cooler

430001919 - Tubing, HPLC Post Column, .005ID
Part Number: 430001919
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC 30cm Column Heater
Replacement Schedule As Needed

info

430001923 - Tubing, HPLC Stainless Steel Inlet

Part Number: 430001923

HPLC Stainless Steel Inlet Tubing, .005ID x 24 long for ACQUITY 30cm Collumn Heater/Cooler

430001923 - Tubing, HPLC Stainless Steel Inlet
Part Number: 430001923
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC 30cm Column Heater
Replacement Schedule As Needed

info

430002007 - ASSY, EXTENSION LOOP, 250uL

Part Number: 430002007

This is a 250µL Sample loop used on the ACQUITY H-Class Sample Manager-FTN and the ACQUITY I-Class Sample Manager-FTN modules.

430002007 - ASSY, EXTENSION LOOP, 250uL
Part Number: 430002007
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category ACQUITY
Products ACQUITY APC SM-pFTN
ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

430002011 - ASSY, EXTENSION LOOP, 100uL

Part Number: 430002011

This is a 100µL Sample loop used on the ACQUITY H-Class Sample Manager-FTN and the ACQUITY I-Class Sample Manager-FTN modules.

430002011 - ASSY, EXTENSION LOOP, 100uL
Part Number: 430002011
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category ACQUITY
Products ACQUITY APC SM-pFTN
ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

430002012 - ASSY, EXTENSION LOOP, 50uL

Part Number: 430002012

This is a 50µL Sample loop used on the ACQUITY H-Class Sample Manager-FTN and the ACQUITY I-Class Sample Manager-FTN modules.

430002012 - ASSY, EXTENSION LOOP, 50uL
Part Number: 430002012
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category ACQUITY
Products ACQUITY APC SM-pFTN
ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

430002015 - Assy, Tube, System Outlet to Col. Man

Part Number: 430002015

This spare part is a Waters Quality part.

430002015 - Assy, Tube, System Outlet to Col. Man
Part Number: 430002015
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products Open Architecture UPLC
Replacement Schedule As Needed

info

430002104 - Tubing Assy, Sparge Vlv to Bulkhead

Part Number: 430002104

This spare part is a Waters Quality part.

430002104 - Tubing Assy, Sparge Vlv to Bulkhead
Part Number: 430002104
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products 2535 Quaternary Gradient Module
Replacement Schedule As Needed

info

430002140 - Tubing, Cap., BSM to MMV tee, 25µx24in.

Part Number: 430002140

The capillary tubing , 25µm x 24in long, fits between the BSM and the nano Tee in the 2D with Dilution configuration of the nanoACQUITY UPLC. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430002140 - Tubing, Cap., BSM to MMV tee, 25µx24in.
Part Number: 430002140
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products nanoACQUITY UPLC with 2D Technology
Replacement Schedule As Needed

info

430002144 - Sample Loading Tube

Part Number: 430002144

This spare part is a Waters Quality part.

430002144 - Sample Loading Tube
Part Number: 430002144
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products 2535 Quaternary Gradient Module
2545 Quaternary Gradient Pump
2555 Quaternary Gradient Module
Replacement Schedule As Needed

info

430002153 - Tubing, Capillary w/Frit, 25µ x 12in.

Part Number: 430002153

This Capillary Tubing connects from the trap valve to the MMV tee on the nanoACQUITY UPLC in the 2D with Dilution Configuration. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page.

430002153 - Tubing, Capillary w/Frit, 25µ x 12in.
Part Number: 430002153
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products nanoACQUITY UPLC with 2D Technology
Replacement Schedule As Needed