Product Listing:  186008297 - Spherisorb C8 OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg   to   186008341 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Sorted by Category
  Product    
info

186008297 - Spherisorb C8 OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008297

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

186008297 - Spherisorb C8 OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008297
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008298 - Spherisorb Cyano (CN) OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008298

The Spherisorb Cyano (CN) chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

186008298 - Spherisorb Cyano (CN) OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008298
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

186008299 - Spherisorb Amino (NH2) OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008299

Spherisorb NH2 (Amino) columns contain a silica-based aminopropyl bonded sorbent. The column is listed as USP L8 and is used for anion-exchange, normal-phase and HILIC separations.

186008299 - Spherisorb Amino (NH2) OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008299
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 1.9
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Parker-style
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

186008300 - Spherisorb Phenyl OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008300

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

186008300 - Spherisorb Phenyl OBD Prep Column, 80Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008300
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008304 - ProteinWorks uElution SPE Clean-up Kit

Part Number: 186008304

The ProteinWorks uElution SPE Clean-up Kit is designed for post-digestion peptide clean-up in LC-MS protein quantification via the surrogate peptide approach. This kit includes an optimized SPE protocol and Oasis uElution technology delivering maximum peptide recovery and the removal of digest reagents and other matrix interferences. The uElution Clean-up kit enhances assay sensitivity and improves LC-MS system robustness.

186008304 - ProteinWorks uElution SPE Clean-up Kit
Part Number: 186008304
Brand: ProteinWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector Mass Spec
Packaging 1/pkg
Product Type Kit
Shipping Formulation Solid

info

186008317 - RapiFluor-MS High Mannose Test Standard

Part Number: 186008317

The RapiFluor-MS High Mannose Standard is intended for use as a proficiency or system suitability test standard. This standard contains approximately 1000 pmoles of purified, RapiFluor-MS labeled N-glycans from bovine ribonuclease B and can be used on its own or it can be spiked into an N-glycan pool for the detection of high mannose structures: M5, M6, M7, M8, and M9.

186008317 - RapiFluor-MS High Mannose Test Standard
Part Number: 186008317
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
System LC/MS

info

186008318 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186008318

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008318 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186008318
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008319 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186008319

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008319 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186008319
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008320 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186008320

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008320 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186008320
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008321 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186008321

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008321 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186008321
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008322 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186008322

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008322 - CORTECS Phenyl Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186008322
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008323 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 30 mm, 3/pkg

Part Number: 186008323

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008323 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 30 mm, 3/pkg
Part Number: 186008323
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008324 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 186008324

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008324 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 186008324
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008325 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg

Part Number: 186008325

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008325 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 75 mm, 3/pkg
Part Number: 186008325
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008326 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186008326

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008326 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 186008326
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008327 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186008327

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008327 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186008327
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008328 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186008328

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008328 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186008328
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008329 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186008329

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008329 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186008329
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008330 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186008330

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008330 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186008330
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008331 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186008331

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008331 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186008331
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008332 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186008332

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008332 - CORTECS Phenyl Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186008332
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008333 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 30 mm, 3/pkg

Part Number: 186008333

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008333 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 30 mm, 3/pkg
Part Number: 186008333
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008334 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 50 mm, 3/pkg

Part Number: 186008334

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008334 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 50 mm, 3/pkg
Part Number: 186008334
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008335 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 75 mm, 3/pkg

Part Number: 186008335

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008335 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 75 mm, 3/pkg
Part Number: 186008335
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008336 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 100 mm, 3/pkg

Part Number: 186008336

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008336 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 100 mm, 3/pkg
Part Number: 186008336
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008337 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 150 mm, 3/pkg

Part Number: 186008337

CORTECS Phenyl method validation kits provide columns of three different batches. CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008337 - CORTECS Phenyl Method Validation Kit, 90Å, 2.7 µm, 3 mm X 150 mm, 3/pkg
Part Number: 186008337
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 3/pkg
pH Range 2 - 8

info

186008338 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186008338

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008338 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186008338
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008339 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186008339

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008339 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186008339
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008340 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186008340

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008340 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186008340
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186008341 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186008341

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008341 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186008341
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8