Product Listing:  186007238 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg   to   186007277 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Sorted by Category
  Product    
info 186007238 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg
Part Number: 186007238
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
Chemistry C18
Format nanoACQUITY Trap 10K psi MV
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Pore Size 100Å
Silanol Activity Low
System Nano/Micro
Units in Package 1/pkg
pH Range 1 - 10

info

186007239 - GlycoWorks HILIC 1cc Flangeless Cartridge

Part Number: 186007239

The GlycoWorks HILIC 1cc Flangeless Cartridge Pack contains 20 1cc cartridges for a total of 10 reactions for low sample volume environments. The flangeless cartridges are designed specifically for customers who use the positive pressure manifold (PPM). The cartridges are dual purpose; they can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each cartridge is packed with 10 mg of Waters HILIC Solid Phase Extraction (SPE).

186007239 - GlycoWorks HILIC 1cc Flangeless Cartridge
Part Number: 186007239
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector Fluorescence (FLR)
Packaging 20/pkg
Product Type Kit
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

186007244 - iKey CSH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg

Part Number: 186007244

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007244 - iKey CSH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg
Part Number: 186007244
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186007245 - iKey CSH C18 Separation Device, 1.7 µm, 150 µm X 100 mm,

Part Number: 186007245

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007245 - iKey CSH C18 Separation Device, 1.7 µm, 150 µm X 100 mm,
Part Number: 186007245
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186007249 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007249

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300, 000 - 2,000, 000 g/mole.

186007249 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007249
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007250 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007250

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007250 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007250
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007251 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007251

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007251 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007251
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007252 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007252

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007252 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007252
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007253 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007253

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007253 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007253
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007254 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007254

ACQUITY APC XT columns are designed to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300, 000 - 2, 000, 000 g/mole.

186007254 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007254
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007256 - iKey BEH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg

Part Number: 186007256

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007256 - iKey BEH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg
Part Number: 186007256
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 10

info

186007257 - iKey Peptide CSH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg

Part Number: 186007257

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007257 - iKey Peptide CSH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pkg
Part Number: 186007257
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 7

info

186007258 - iKey BEH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 100 mm, 1/pkg

Part Number: 186007258

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007258 - iKey BEH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 100 mm, 1/pkg
Part Number: 186007258
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 10

info

186007259 - iKey Peptide CSH C18 Separation Device, 1.7 µm, 150 µm X 100 mm,

Part Number: 186007259

The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. The innovative iKey eliminates the need for traditional fittings and greatly simplifies the microflow-LC user experience. Available with an internal diameter of 150 µm and in 50 mm and 100 mm lengths, the iKey brings microflow LC into the mainstream of chromatographic laboratories.

186007259 - iKey Peptide CSH C18 Separation Device, 1.7 µm, 150 µm X 100 mm,
Part Number: 186007259
Brand: iKey

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Format Separation Device
ID 150 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186007262 - XBridge Glycan BEH Amide VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007262

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007262 - XBridge Glycan BEH Amide VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007262
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11

info

186007263 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186007263

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007263 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186007263
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007264

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007264
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007266 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186007266

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007266 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186007266
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11

info

186007267 - XBridge Glycan BEH Amide Sentry Guard Cartridge, 130Å, 2.5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186007267

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007267 - XBridge Glycan BEH Amide Sentry Guard Cartridge, 130Å, 2.5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186007267
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 2/pkg
pH Range 2 - 11

info

186007268 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186007268

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007268 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186007268
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007269 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186007269

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007269 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186007269
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007271 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186007271

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007271 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186007271
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11

info

186007272 - XBridge Glycan BEH Amide Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186007272

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007272 - XBridge Glycan BEH Amide Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186007272
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 2/pkg
pH Range 2 - 11

info

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186007273

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186007273
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007274 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186007274

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007274 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186007274
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007275 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007275

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007275 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007275
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007276 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186007276

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007276 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186007276
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007277 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186007277

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007277 - XBridge Glycan BEH Amide Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186007277
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11