Product Listing:  186006891 - XBridge BEH Phenyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg   to   186006950 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Sorted by Category
  Product    
info

186006891 - XBridge BEH Phenyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006891

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006891 - XBridge BEH Phenyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006891
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186006892 - XBridge BEH C18 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006892

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006892 - XBridge BEH C18 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006892
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186006894 - XBridge BEH C8 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006894

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006894 - XBridge BEH C8 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006894
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006895 - XBridge BEH C8 Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006895

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006895 - XBridge BEH C8 Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006895
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006896 - XBridge BEH HILIC Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006896

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006896 - XBridge BEH HILIC Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006896
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 8

info

186006897 - XBridge BEH Shield RP18 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006897

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006897 - XBridge BEH Shield RP18 Prep Guard Cartridge, 130Å, 10 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006897
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186006899 - XSelect CSH C18 Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006899

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006899 - XSelect CSH C18 Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006899
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006901 - XSelect CSH Phenyl-Hexyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006901

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006901 - XSelect CSH Phenyl-Hexyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006901
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186006904 - XTerra MS C8 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006904

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006904 - XTerra MS C8 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006904
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006906 - XTerra RP18 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006906

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006906 - XTerra RP18 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006906
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology RP18
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186006909 - Viridis BEH 2-Ethylpyridine Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006909

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006909 - Viridis BEH 2-Ethylpyridine Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006909
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode SuperCritical Fluid (SFC)
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 130Å
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006911 - Viridis BEH Fluoro Phenyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg

Part Number: 186006911

30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006911 - Viridis BEH Fluoro Phenyl Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pkg
Part Number: 186006911
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry Phenyl
Endcapped No
Format Prep Guard Cartridge
ID 30 mm
Length (mm) 10 mm
Mode SuperCritical Fluid (SFC)
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 130Å
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006912 - 30 mm x10 mm Prep Guard Holder

Part Number: 186006912

30x10mm Prep Guard Holder in combination with a 30x10mm Prep Guard Cartridge is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

186006912 - 30 mm x10 mm Prep Guard Holder
Part Number: 186006912
Products > Chromatography Consumables & Columns > Columns > HPLC Columns
ID 30 mm
Length (mm) 10 mm
Units in Package 1/pkg

info

186006918 - Proteomics Training Kit Standards-1

Part Number: 186006918

Proteomics Training Kit Standards-1 A kit containing an array of compounds to enable training, demonstration and system use, in relation to the proteomics field. Kit contains: 1 vial of 10 pmol Hi3 E Coli peptide standard, 1 vial of 10 pmol Hi3 Phos B peptide standard, a 30 mL container of 2ug/uL sodium iodide, 50 ng/uL cesium iodide in 50:50 Isopranol:water, 1 vial of ~ 1nmole E Coli digestion standard, 1 vial of digestion standards mix #1, 1 vial of digestion standards mix 2, 1 vial of 10 pmol SILAC Hi3 E Coli peptide standard, and 1 vial of 10 pmol SILAC Hi3 Phos B peptide standard.

186006918 - Proteomics Training Kit Standards-1
Part Number: 186006918
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Packaging Kit
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Room temp
System LC/MS

info

186006930 - HDX Phos B Check Standard

Part Number: 186006930

The HDX Phos B Check Standard is lyophilized powder of 0.62mg of Phosphorylase B from Rabbit Muscle Intact Protein in a Waters TruView Max Recovery vial. This standard is used to help evaluate the HDX system and can be directly complimented with it's digested counterpart, the MassPREP Phos B Digestion Standard PN 186002326.

186006930 - HDX Phos B Check Standard
Part Number: 186006930
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

186006933 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1/pkg

Part Number: 186006933

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006933 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1/pkg
Part Number: 186006933
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006934 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pkg

Part Number: 186006934

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006934 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pkg
Part Number: 186006934
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006935 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pkg

Part Number: 186006935

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006935 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pkg
Part Number: 186006935
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006936 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006936

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006936 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006936
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006937 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006937

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006937 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006937
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006938

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006938
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006939

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006939
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186006940 - ACQUITY UPLC Peptide CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006940

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit consists of three ACQUITY UPLC CSH130 C18 columns packed with three different batches of sorbent.

186006940 - ACQUITY UPLC Peptide CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186006940
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186006941 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006941

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006941 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006941
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006942 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006942

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006942 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006942
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006943

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006943
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006944 - XSelect Peptide CSH C18 VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006944

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186006944 - XSelect Peptide CSH C18 VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006944
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped No
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186006946 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186006946

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006946 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186006946
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006947 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186006947

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006947 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186006947
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006950 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006950

Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006950 - XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006950
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11