Product Listing:  186006577 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pkg   to   186006629 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 3 mm X 50 mm, 1/pkg

Sorted by Category
  Product    
info

186006577 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186006577

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006577 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186006577
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006578 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006578

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006578 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006578
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006579 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006579

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006579 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006579
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006580 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186006580

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006580 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186006580
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006581 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186006581

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006581 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186006581
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006582 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006582

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006582 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006582
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006587 - XBridge BEH Amide Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186006587

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006587 - XBridge BEH Amide Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186006587
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006590 - XBridge BEH Amide Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006590

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006590 - XBridge BEH Amide Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006590
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006592 - XBridge BEH Amide Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006592

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006592 - XBridge BEH Amide Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006592
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006593 - XBridge BEH Amide Column, 130Å, 5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186006593

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006593 - XBridge BEH Amide Column, 130Å, 5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186006593
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006603 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg

Part Number: 186006603

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006603 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg
Part Number: 186006603
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006604 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Part Number: 186006604

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006604 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg
Part Number: 186006604
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006606 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186006606

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006606 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186006606
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006609 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186006609

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006609 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186006609
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006611 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186006611

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa.

186006611 - XBridge BEH Amide OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186006611
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing

Part Number: 186006613

0.005 x 1.75 UPLC SEC Connection Tubing

186006613 - 0.005" x 1.75" UPLC SEC Connection Tubing
Part Number: 186006613
Products > Chromatography Consumables & Columns > Accessories > Tubing
Hardware Type Tubing
Inside Diameter 0.005 in. (0.127 mm)

info

186006616 - Viridis HSS C18 SB VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006616

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006616 - Viridis HSS C18 SB VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006616
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 3/pkg

info

186006617 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006617

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006617 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006617
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006618 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186006618

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006618 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186006618
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006619 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006619

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006619 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006619
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006620 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006620

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006620 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006620
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006621 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186006621

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006621 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186006621
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006622 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186006622

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006622 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186006622
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006623 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006623

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006623 - Viridis HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006623
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006624 - Viridis HSS C18 SB VanGuard Pre-column, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006624

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006624 - Viridis HSS C18 SB VanGuard Pre-column, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006624
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 3/pkg

info

186006625 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006625

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006625 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006625
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006626 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186006626

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006626 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186006626
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006627 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006627

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006627 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006627
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006628 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006628

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006628 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006628
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg

info

186006629 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186006629

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006629 - Viridis HSS C18 SB Column, 100Å, 3.5 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186006629
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPC2/SFC
Technology HSS
Units in Package 1/pkg