Product Listing:  WAT044207 - Styragel Column, HT 3, 10 µm, 7.8 mm X 300 mm, 500 - 30K, THF , 1/pkg   to   186007706 - SunFire C8 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Sorted by Brand
  Product    
info

WAT044207 - Styragel Column, HT 3, 10 µm, 7.8 mm X 300 mm, 500 - 30K, THF , 1/pkg

Part Number: WAT044207

Styragel HT columns are packed with 10 µm particles with a narrow particle size distribution, enhancing the packed-bed stability in the column. These rugged GPC columns deliver exceptional column lifetime in high-temperature GPC applications

WAT044207 - Styragel Column, HT 3, 10 µm, 7.8 mm X 300 mm, 500 - 30K, THF , 1/pkg
Part Number: WAT044207
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 30K
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size HT 3
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044206 - Styragel Column, HT 3, 10 µm, 7.8 mm X 300 mm, 500 - 30K, Toluene , 1/pkg

Part Number: WAT044206

Styragel HT columns are packed with 10 µm particles with a narrow particle size distribution, enhancing the packed-bed stability in the column. These rugged GPC columns deliver exceptional column lifetime in high-temperature GPC applications

WAT044206 - Styragel Column, HT 3, 10 µm, 7.8 mm X 300 mm, 500 - 30K, Toluene , 1/pkg
Part Number: WAT044206
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 30K
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size HT 3
Solvent Toluene
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044205 - Styragel Column, HMW 6E, 20 µm, 7.8 mm X 300 mm, 5K - 10M, DMF , 1/pkg

Part Number: WAT044205

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044205 - Styragel Column, HMW 6E, 20 µm, 7.8 mm X 300 mm, 5K - 10M, DMF , 1/pkg
Part Number: WAT044205
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 5K - 10M
Particle Shape Spherical
Particle Size (dp) 20 µm
Particle Substrate Polymer
Pore Size HMW 6E
Solvent DMF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044204 - Styragel Column, HMW 6E, 15-20 µm, 7.8 mm X 300 mm, 5K - 10M, THF , 1/pkg

Part Number: WAT044204

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044204 - Styragel Column, HMW 6E, 15-20 µm, 7.8 mm X 300 mm, 5K - 10M, THF , 1/pkg
Part Number: WAT044204
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 5K - 10M
Particle Shape Spherical
Particle Size (dp) 15-20 µm
Particle Substrate Polymer
Pore Size HMW 6E
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044203 - Styragel Column, HMW 6E, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, Toluene , 1/pkg

Part Number: WAT044203

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044203 - Styragel Column, HMW 6E, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, Toluene , 1/pkg
Part Number: WAT044203
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500K - 100M
Particle Shape Spherical
Particle Size (dp) 15-20 µm
Particle Substrate Polymer
Pore Size HMW 6E
Solvent Toluene
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044202 - Styragel Column, HMW 7, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, DMF , 1/pkg

Part Number: WAT044202

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044202 - Styragel Column, HMW 7, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, DMF , 1/pkg
Part Number: WAT044202
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500K - 100M
Particle Shape Spherical
Particle Size (dp) 15-20 µm
Particle Substrate Polymer
Pore Size HMW 7
Solvent DMF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044201 - Styragel Column, HMW 7, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, THF , 1/pkg

Part Number: WAT044201

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044201 - Styragel Column, HMW 7, 15-20 µm, 7.8 mm X 300 mm, 500K - 100M, THF , 1/pkg
Part Number: WAT044201
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500K - 100M
Particle Shape Spherical
Particle Size (dp) 15-20 µm
Particle Substrate Polymer
Pore Size HMW 7
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044200 - Styragel Column, 15-20 µm, 7.8 mm X 300 mm, 500000 - 100000000, Toluene , 1/pkg

Part Number: WAT044200

Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.

WAT044200 - Styragel Column, 15-20 µm, 7.8 mm X 300 mm, 500000 - 100000000, Toluene , 1/pkg
Part Number: WAT044200
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 15-20 µm
Particle Substrate Polymer
Solvent Toluene
Units in Package 1/pkg
pH Range 2 - 12

info

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg

Part Number: WAT085188

The Sugar Pak I column separates monosaccharides and sugar alcohols via a strong cation-exchange mechanism. The resin is based on a sulfonated styrene-divinylbenzene polymer that provides pH stability by means of a calcium counterion.

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg
Part Number: WAT085188
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column
Length (mm) 300 mm
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 1/pkg

info

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg

Part Number: WAT015209

The Sugar-Pak I Guard-Pak Insert is used to extend and prolong the lifetime for the Sugar Pak I Column by removing chemical and particulate contaminants from the mobile phase stream.

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg
Part Number: WAT015209
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Guard-Pak Insert
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 10/pkg

info

186008209 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008209

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008209 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008209
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008208 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008208

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008208 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008208
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008183 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008183

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186008183 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008183
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186008182 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008182

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186008182 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008182
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186008181 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg

Part Number: 186008181

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186008181 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg
Part Number: 186008181
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186008180 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008180

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186008180 - SunFire Silica OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008180
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186008163 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008163

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008163 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008163
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008162 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008162

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008162 - SunFire C8 OBD Prep Column, 100Å, 10 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008162
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008161 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008161

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008161 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008161
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008160 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008160

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008160 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008160
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008159 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg

Part Number: 186008159

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008159 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg
Part Number: 186008159
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008158 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008158

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186008158 - SunFire C8 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008158
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008157 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008157

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008157 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008157
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008156 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008156

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008156 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008156
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008155 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg

Part Number: 186008155

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008155 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 250 mm, 1/pkg
Part Number: 186008155
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008154 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg

Part Number: 186008154

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008154 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 150 mm, 1/pkg
Part Number: 186008154
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008153 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg

Part Number: 186008153

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008153 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 100 mm, 1/pkg
Part Number: 186008153
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008152 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008152

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186008152 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008152
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007708 - SunFire C8 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg

Part Number: 186007708

SunFire C8 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. SunFire C8 analytical columns containing 5 µm sorbent particles.

186007708 - SunFire C8 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pkg
Part Number: 186007708
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 3.9 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8

info

186007706 - SunFire C8 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007706

SunFire C8 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. SunFire C8 analytical columns containing 5 µm sorbent particles.

186007706 - SunFire C8 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007706
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8