Product Listing:  WAT038511 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 6 µm, 25 mm X 100 mm, 1/pkg   to   WAT010658 - Nova-Pak Phenyl Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg

Sorted by Brand
  Product    
info

WAT038511 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 6 µm, 25 mm X 100 mm, 1/pkg

Part Number: WAT038511

Nova-Pak HR Silica columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT038511 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 6 µm, 25 mm X 100 mm, 1/pkg
Part Number: WAT038511
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Radial-Pak Cartridge
ID 25 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT038510 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 25 mm X 100 mm, 1/pkg

Part Number: WAT038510

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT038510 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 25 mm X 100 mm, 1/pkg
Part Number: WAT038510
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Radial-Pak Cartridge
ID 25 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT038501 - Nova-Pak Silica Column, 60Å, 6 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT038501

Nova-Pak HR Silica columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT038501 - Nova-Pak Silica Column, 60Å, 6 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT038501
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT038500 - Nova-Pak C18 Column, 60Å, 6 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT038500

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT038500 - Nova-Pak C18 Column, 60Å, 6 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT038500
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT037857 - Nova-Pak Silica Radial-Pak Guard, 60Å, 6 µm, 40 mm X 10 mm, 2/pkg

Part Number: WAT037857

Nova-Pak HR Silica columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT037857 - Nova-Pak Silica Radial-Pak Guard, 60Å, 6 µm, 40 mm X 10 mm, 2/pkg
Part Number: WAT037857
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Radial-Pak Guard
ID 40 mm
Length (mm) 10 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 2/pkg
pH Range 2 - 8

info

WAT037854 - Nova-Pak C18 Radial-Pak Guard, 60Å, 6 µm, 40 mm X 10 mm, 2/pkg

Part Number: WAT037854

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT037854 - Nova-Pak C18 Radial-Pak Guard, 60Å, 6 µm, 40 mm X 10 mm, 2/pkg
Part Number: WAT037854
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Radial-Pak Guard
ID 40 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

WAT037704 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 40 mm X 100 mm, 1/pkg

Part Number: WAT037704

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT037704 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 40 mm X 100 mm, 1/pkg
Part Number: WAT037704
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Radial-Pak Cartridge
ID 40 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT036985 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036985

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT036985 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036985
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT036980 - Nova-Pak Silica Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036980

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT036980 - Nova-Pak Silica Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036980
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT036975 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036975

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT036975 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036975
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT036970 - Nova-Pak Phenyl Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036970

Nova-Pak HP Phenyl columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.

WAT036970 - Nova-Pak Phenyl Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036970
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.6
Chemistry Phenyl
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035890 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg

Part Number: WAT035890

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035890 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg
Part Number: WAT035890
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Radial-Pak Cartridge
ID 5 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035884 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT035884

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035884 - Nova-Pak C8 Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT035884
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035880 - Nova-Pak C8 Guard-Pak Insert, 60Å, 4 µm, 10/pkg

Part Number: WAT035880

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT035880 - Nova-Pak C8 Guard-Pak Insert, 60Å, 4 µm, 10/pkg
Part Number: WAT035880
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C8
Format Guard-Pak Insert
Particle Size (dp) 4 µm
Pore Size 60Å
System HPLC
Units in Package 10/pkg

info

WAT035877 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg

Part Number: WAT035877

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035877 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg
Part Number: WAT035877
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035876 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT035876

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035876 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT035876
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025844 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 6 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT025844

Nova-Pak HR Silica columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025844 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 6 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT025844
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025843 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT025843

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025843 - Nova-Pak C18 Radial-Pak Cartridge, 60Å, 6 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT025843
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025823 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg

Part Number: WAT025823

Nova-Pak HR Silica columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025823 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg
Part Number: WAT025823
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025822 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg

Part Number: WAT025822

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025822 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg
Part Number: WAT025822
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025821 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg

Part Number: WAT025821

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025821 - Nova-Pak Silica Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg
Part Number: WAT025821
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Prep Column
ID 7.8 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025820 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg

Part Number: WAT025820

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025820 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 7.8 mm X 300 mm, 1/pkg
Part Number: WAT025820
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 7.8 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT023655 - Nova-Pak C18 Column, 60Å, 4 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: WAT023655

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT023655 - Nova-Pak C18 Column, 60Å, 4 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: WAT023655
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT015220 - Nova-Pak C18 Guard-Pak Insert, 60Å, 4 µm, 10/pkg

Part Number: WAT015220

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT015220 - Nova-Pak C18 Guard-Pak Insert, 60Å, 4 µm, 10/pkg
Part Number: WAT015220
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Format Guard-Pak Insert
Particle Size (dp) 4 µm
Pore Size 60Å
System HPLC
Units in Package 10/pkg

info

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT011695

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT011695
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011675 - Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg

Part Number: WAT011675

Nova-Pak HP Phenyl columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.

WAT011675 - Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg
Part Number: WAT011675
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.6
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011670 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg

Part Number: WAT011670

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT011670 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg
Part Number: WAT011670
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010987 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT010987

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT010987 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT010987
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010986 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg

Part Number: WAT010986

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT010986 - Nova-Pak Silica Radial-Pak Cartridge, 60Å, 4 µm, 5 mm X 100 mm, 1/pkg
Part Number: WAT010986
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Radial-Pak Cartridge
ID 5 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity High
Surface Area 120
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010658 - Nova-Pak Phenyl Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT010658

Nova-Pak HP Phenyl columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.

WAT010658 - Nova-Pak Phenyl Radial-Pak Cartridge, 60Å, 4 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT010658
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.6
Chemistry Phenyl
Endcapped Yes
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8