Product Listing:  186005534 - ACQUITY - Xselect CSH Fluoro Phenyl Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg   to   186006990 - ACQUITY APC AQ - Aqueous Column, 450Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Brand
  Product    
info

186005534 - ACQUITY - Xselect CSH Fluoro Phenyl Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg

Part Number: 186005534

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005534 - ACQUITY - Xselect CSH Fluoro Phenyl Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg
Part Number: 186005534
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 100mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L43
Units in Package 2/pkg
pH Range 1 - 8

info

186005533 - ACQUITY - Xselect CSH Phenyl-Hexyl Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg

Part Number: 186005533

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005533 - ACQUITY - Xselect CSH Phenyl-Hexyl Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg
Part Number: 186005533
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 100mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L11
Units in Package 2/pkg
pH Range 1 - 11

info

186005532 - ACQUITY - Xselect CSH C18 Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg

Part Number: 186005532

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005532 - ACQUITY - Xselect CSH C18 Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg
Part Number: 186005532
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 100mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 11

info

186005531 - ACQUITY - Xselect CSH Fluoro Phenyl Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg

Part Number: 186005531

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005531 - ACQUITY - Xselect CSH Fluoro Phenyl Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg
Part Number: 186005531
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L43
Units in Package 2/pkg
pH Range 1 - 8

info

186005530 - ACQUITY - Xselect CSH Phenyl-Hexyl Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg

Part Number: 186005530

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005530 - ACQUITY - Xselect CSH Phenyl-Hexyl Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg
Part Number: 186005530
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L11
Units in Package 2/pkg
pH Range 1 - 11

info

186005529 - ACQUITY - Xselect CSH C18 Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg

Part Number: 186005529

ACQUITY Method Transfer Kits contain an ACQUITY CSH column and matching XSelect HPLC column. The columns contained in an ACQUITY CSH Method Transfer Kit possess the same length to particle size (l/dp) ratio and will provide the same selectivity.

186005529 - ACQUITY - Xselect CSH C18 Method Transfer Kit, 130Å, 1.7 - 5 µm, 2.1 - 4.6 mm X 50 - 150mm, 2/pkg
Part Number: 186005529
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 - 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
Technology CSH
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 11

info

186004977 - HSS C18 SB 100mm,1.8µm to 150mm, 3.5µm High Rs Method Transfer Kit, 2/pk

Part Number: 186004977

Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.

186004977 - HSS C18 SB 100mm,1.8µm to 150mm, 3.5µm High Rs Method Transfer Kit, 2/pk
Part Number: 186004977
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 - 3.5 µm
Pore Size 100Å
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186004975 - HSS C18 100mm,1.8µm to 150mm, 3.5µm High Rs Method Transfer Kit, 2/pk

Part Number: 186004975

Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.

186004975 - HSS C18 100mm,1.8µm to 150mm, 3.5µm High Rs Method Transfer Kit, 2/pk
Part Number: 186004975
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 - 3.5 µm
Pore Size 100Å
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 8

info

186004969 - ACQUITY - Xselect HSS T3 Method Transfer Kit, 100Å, 1.8 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg

Part Number: 186004969

Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.

186004969 - ACQUITY - Xselect HSS T3 Method Transfer Kit, 100Å, 1.8 - 3.5 µm, 2.1 - 4.6 mm X 50 - 100mm, 2/pkg
Part Number: 186004969
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 50 - 100mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 - 3.5 µm
Pore Size 100Å
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186004963 - HSS C18 SB 50mm,1.8µm to 150mm, 5µm Method Transfer Kit, 2/pk

Part Number: 186004963

Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.

186004963 - HSS C18 SB 50mm,1.8µm to 150mm, 5µm Method Transfer Kit, 2/pk
Part Number: 186004963
Brand: ACQUITY - Xselect

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 8.5
Bonding Technology C18 SB
Chemistry C18
Endcapped No
Format Method Transfer Kit
ID 2.1 - 4.6 mm
Length (mm) 100 - 150mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 - 5 µm
Pore Size 100Å
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186008782 - ACQUITY UPLC Peptide HSS T3 C18 Column, 100Å , 1.8 µm, 2.1 x 150 mm, 3/pkg

Part Number: 186008782

Peptide HSS T3 Columns are designed for separations where silica-based selectivities are desired or when increased retention of hydrophilic peptides are required. This Method Validation Kit contains three columns from three differenct batches of material.

186008782 - ACQUITY UPLC Peptide HSS T3 C18 Column, 100Å , 1.8 µm, 2.1 x 150 mm, 3/pkg
Part Number: 186008782
Brand: ACQUITY

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007254 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007254

ACQUITY APC XT columns are designed to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300, 000 - 2, 000, 000 g/mole.

186007254 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007254
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007253 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007253

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007253 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007253
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007252 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007252

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007252 - ACQUITY APC XT - Extended Temperature Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007252
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007251 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007251

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007251 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007251
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007250 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007250

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300,000 - 2,000,000 g/mole.

186007250 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007250
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007249 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007249

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 300, 000 - 2,000, 000 g/mole.

186007249 - ACQUITY APC AQ - Aqueous Column, 900Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007249
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 900Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8

info

186007010 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007010

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 20,000 - 400,000 g/mole.

186007010 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007010
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 450Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007008 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007008

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 20,000 - 400,000 g/mole.

186007008 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007008
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 450Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007007 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007007

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 20,000 - 400,000 g/mole.

186007007 - ACQUITY APC XT - Extended Temperature Column, 450Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007007
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 450Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007005 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007005

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 3,000 - 70,000 g/mole.

186007005 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007005
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 200Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007003 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186007003

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 3,000 - 70,000 g/mole.

186007003 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186007003
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 200Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007002 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186007002

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 3,000 - 70,000 g/mole.

186007002 - ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186007002
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 200Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186007000 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007000

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 1,000 - 30,000 g/mole.

186007000 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007000
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006998 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186006998

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 1,000 - 30,000 g/mole.

186006998 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186006998
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006997 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006997

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 1,000 - 30,000 g/mole.

186006997 - ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006997
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006995 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006995

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 200 - 5, 000 g/mole.

186006995 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006995
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 45Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006993 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: 186006993

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 200 - 5, 000 g/mole.

186006993 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: 186006993
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 45Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006992 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006992

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 200 - 5, 000 g/mole.

186006992 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006992
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 45Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

186006990 - ACQUITY APC AQ - Aqueous Column, 450Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006990

ACQUITY APC AQ columns are designed to provide highly efficient size-based separations for water soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching. The expected molecular weight range for this column is approximatley 20,000 - 400, 000 g/mole.

186006990 - ACQUITY APC AQ - Aqueous Column, 450Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006990
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry AQ - Aqueous
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 450Å
Silanol Activity Medium
System APC
Units in Package 1/pkg
pH Range 1 - 8