Product Listing:  176001051 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg   to   186008006 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 75 µm X 100 mm, 1/pkg

Sorted by Brand
  Product    
info

176001051 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 176001051

ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.

176001051 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 176001051
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176001049 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 176001049

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176001049 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 176001049
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 176001048

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 176001048
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176001047 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg

Part Number: 176001047

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

176001047 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg
Part Number: 176001047
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176001046 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg

Part Number: 176001046

The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

176001046 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg
Part Number: 176001046
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L7
Units in Package 3/pkg
pH Range 1 - 12

info

176001045 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg

Part Number: 176001045

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176001045 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg
Part Number: 176001045
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176001044 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg

Part Number: 176001044

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176001044 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 3/pkg
Part Number: 176001044
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176001043 - ACQUITY UPLC Method Development Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 4/pkg

Part Number: 176001043

ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.

176001043 - ACQUITY UPLC Method Development Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 4/pkg
Part Number: 176001043
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Endcapped Yes
Endfitting Type Waters
Format Method Development Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Units in Package 4/pkg

info

176001042 - ACQUITY UPLC Method Development Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 4/pkg

Part Number: 176001042

ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.

176001042 - ACQUITY UPLC Method Development Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 4/pkg
Part Number: 176001042
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Endcapped Yes
Endfitting Type Waters
Format Method Development Kit
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Units in Package 4/pkg

info

176000908 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176000908

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

176000908 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176000908
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176000907 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 176000907

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

176000907 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 176000907
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176000906 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg

Part Number: 176000906

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

176000906 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg
Part Number: 176000906
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176000905 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg

Part Number: 176000905

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

176000905 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg
Part Number: 176000905
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 12

info

176000884 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 176000884

The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

176000884 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 176000884
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L7
Units in Package 3/pkg
pH Range 1 - 12

info

176000883 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg

Part Number: 176000883

The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

176000883 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg
Part Number: 176000883
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L7
Units in Package 3/pkg
pH Range 1 - 12

info

176000882 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg

Part Number: 176000882

The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

176000882 - ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg
Part Number: 176000882
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L7
Units in Package 3/pkg
pH Range 1 - 12

info

176000877 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176000877

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176000877 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176000877
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176000876 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 176000876

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176000876 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 176000876
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176000875 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg

Part Number: 176000875

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176000875 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg
Part Number: 176000875
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176000874 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg

Part Number: 176000874

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

176000874 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg
Part Number: 176000874
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

176000864 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176000864

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176000864 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176000864
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176000863 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg

Part Number: 176000863

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176000863 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg
Part Number: 176000863
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176000862 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg

Part Number: 176000862

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176000862 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pkg
Part Number: 176000862
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176000861 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg

Part Number: 176000861

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176000861 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 3/pkg
Part Number: 176000861
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg

Part Number: 186008470

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 300A pore, C4, 1.7um particles and each batch is specifically QC tested with a carefully selected protein standard mix to help ensure consistent performance and increased analytical column life.

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg
Part Number: 186008470
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 8
Chemistry C4
Endcapped No
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
Silanol Activity Low
Surface Area 90
System Nano/Micro
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 10

info

186008029 - ACQUITY UPLC M-Class HSS T3 Trap Column, 100Å, 5 µm, 300 µm X 50 mm, 1/pkg

Part Number: 186008029

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. As the 75µm to 180µm ID columns are fritted with a novel frit technology, they are able to withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters HSS (High Strength Silica) Technology 100A pore, C18, 1.8um particles. The High Strength Silica particle overcomes the mechanical limitation of porous silica particles withstanding pressures for UPLC separations. The T3 bonding utilizes a trifunctional C18 Alkyl phase bonded at a ligand density that promotes polar compound retention and aqueous mobile phase compatibility.

186008029 - ACQUITY UPLC M-Class HSS T3 Trap Column, 100Å, 5 µm, 300 µm X 50 mm, 1/pkg
Part Number: 186008029
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008009 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 150 µm X 100 mm, 1/pkg

Part Number: 186008009

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. As the 75µm to 180µm ID columns are fritted with a novel frit technology, they are able to withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters HSS (High Strength Silica) Technology 100A pore, C18, 1.8um particles. The High Strength Silica particle overcomes the mechanical limitation of porous silica particles withstanding pressures for UPLC separations. The T3 bonding utilizes a trifunctional C18 Alkyl phase bonded at a ligand density that promotes polar compound retention and aqueous mobile phase compatibility.

186008009 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 150 µm X 100 mm, 1/pkg
Part Number: 186008009
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 150 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008008 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 100 µm X 100 mm, 1/pkg

Part Number: 186008008

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. As the 75µm to 180µm ID columns are fritted with a novel frit technology, they are able to withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely wel?l and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters HSS (High Strength Silica) Technology 100A pore, C18, 1.8um particles. The High Strength Silica particle overcomes the mechanical limitation of porous silica particles withstanding pressures for UPLC separations. The T3 bonding utilizes a trifunctional C18 Alkyl phase bonded at a ligand density that promotes polar compound retention and aqueous mobile phase compatibility.

186008008 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 100 µm X 100 mm, 1/pkg
Part Number: 186008008
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 100 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008007 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 75 µm X 200 mm, 1/pkg

Part Number: 186008007

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation for biomarker discovery and protein and peptide identification and characterization. All M-Class columns are designed for 15 kpsi (1,000 bar) operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. This specific offering contains Waters patented HSS Technology 100 Å pore, T3, 1.8um particles. The mechanically tolerant High Strength Silica [HSS] particle technology was developed to compliment Waters Hybrid Particle Technology [BEH and CSH]. HSS allows for silica based LC separations under UPLC conditions. The particle technology provides the highest retentivity for polar compounds and metabolites while keeping in the retention between polar and hydrophobic analytes balanced. The higher retention may result in enhanced sensitivity due to improved desolvation as polar analytes elute in a higher percentage organic mobile phase. The T3 bonding utilizes a trifunctional C18 Alkyl phase bonded at a ligand density that promotes polar compound retention and aqueous mobile phase compatibility. .

186008007 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 75 µm X 200 mm, 1/pkg
Part Number: 186008007
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 200 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008006 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 75 µm X 100 mm, 1/pkg

Part Number: 186008006

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation for biomarker discovery and protein and peptide identification and characterization. All M-Class columns are designed for 15 kpsi (1,000 bar) operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. This specific offering contains Waters patented HSS Technology 100 Å pore, T3, 1.8um particles. The mechanically tolerant High Strength Silica [HSS] particle technology was developed to compliment Waters Hybrid Particle Technology [BEH and CSH]. HSS allows for silica based LC separations under UPLC conditions. The particle technology provides the highest retentivity for polar compounds and metabolites while keeping in the retention between polar and hydrophobic analytes balanced. The higher retention may result in enhanced sensitivity due to improved desolvation as polar analytes elute in a higher percentage organic mobile phase. The T3 bonding utilizes a trifunctional C18 Alkyl phase bonded at a ligand density that promotes polar compound retention and aqueous mobile phase compatibility.

186008006 - ACQUITY UPLC M-Class HSS T3 Column, 100Å, 1.8 µm, 75 µm X 100 mm, 1/pkg
Part Number: 186008006
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8