Product Listing:  PSS833512 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 100 mm, 1/pkg   to   PSS839474 - Spherisorb C6 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Sorted by Title
  Product    
info

PSS833512 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: PSS833512

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS833512 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: PSS833512
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833513 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS833513

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS833513 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS833513
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833515 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS833515

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS833515 - Spherisorb Cyano (CN) Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS833515
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833615 - Spherisorb Amino (NH2) Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS833615

Spherisorb NH2 (Amino) columns contain a silica-based aminopropyl bonded sorbent. The column is listed as USP L8 and is used for anion-exchange, normal-phase and HILIC separations.

PSS833615 - Spherisorb Amino (NH2) Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS833615
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 1.9
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833695 - Spherisorb Amino (NH2) Prep Column, 80Å, 10 µm, 20 mm X 250 mm, 1/pkg

Part Number: PSS833695

Spherisorb NH2 (Amino) columns contain a silica-based aminopropyl bonded sorbent. The column is listed as USP L8 and is used for anion-exchange, normal-phase and HILIC separations.

PSS833695 - Spherisorb Amino (NH2) Prep Column, 80Å, 10 µm, 20 mm X 250 mm, 1/pkg
Part Number: PSS833695
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 1.9
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Parker-style
Format Prep Column
ID 20 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833711 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: PSS833711

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

PSS833711 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: PSS833711
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833712 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: PSS833712

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

PSS833712 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: PSS833712
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833713 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS833713

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

PSS833713 - Spherisorb Phenyl Column, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS833713
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833813 - Spherisorb Phenyl Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS833813

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

PSS833813 - Spherisorb Phenyl Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS833813
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833815 - Spherisorb Phenyl Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS833815

Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.

PSS833815 - Spherisorb Phenyl Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS833815
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.5
Chemistry Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833912 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: PSS833912

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

PSS833912 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: PSS833912
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SAX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L14
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833913 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS833913

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

PSS833913 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS833913
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SAX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L14
Units in Package 1/pkg
pH Range 2 - 8

info

PSS833915 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS833915

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

PSS833915 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS833915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SAX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L14
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837512 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: PSS837512

Spherisorb SCX columns contain an anionic silica-based sorbent. This strong cation- exchange sorbent is used to separate positively charged ionic species.

PSS837512 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: PSS837512
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SCX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837513 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS837513

Spherisorb SCX columns contain an anionic silica-based sorbent. This strong cation- exchange sorbent is used to separate positively charged ionic species.

PSS837513 - Spherisorb SCX Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS837513
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SCX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837613 - Spherisorb SCX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS837613

Spherisorb SCX columns contain an anionic silica-based sorbent. This strong cation- exchange sorbent is used to separate positively charged ionic species.

PSS837613 - Spherisorb SCX Column, 80Å, 10 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS837613
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SCX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837813 - Spherisorb Cyano (CN) Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS837813

Spherisorb OD/CN columns contain a mixed-mode sorbent comprised of Nitrile (CN) and ODS (C18) ligands. The OD/CN sorbent provides alternative reversed-phase selectivity compared to the Spherisorb ODS sorbents.

PSS837813 - Spherisorb Cyano (CN) Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS837813
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS837815 - Spherisorb Cyano (CN) Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS837815

Spherisorb OD/CN columns contain a mixed-mode sorbent comprised of Nitrile (CN) and ODS (C18) ligands. The OD/CN sorbent provides alternative reversed-phase selectivity compared to the Spherisorb ODS sorbents.

PSS837815 - Spherisorb Cyano (CN) Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS837815
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838522 - Spherisorb ODS2 Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg

Part Number: PSS838522

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS838522 - Spherisorb ODS2 Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg
Part Number: PSS838522
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838524 - Spherisorb Cyano (CN) Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg

Part Number: PSS838524

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS838524 - Spherisorb Cyano (CN) Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg
Part Number: PSS838524
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Format Cartridge
ID 3 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838525 - Spherisorb C8 Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg

Part Number: PSS838525

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS838525 - Spherisorb C8 Cartridge, 80Å, 5 µm, 3 mm X 250 mm, 1/pkg
Part Number: PSS838525
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838528 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 3 mm X 125 mm, 1/pkg

Part Number: PSS838528

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS838528 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 3 mm X 125 mm, 1/pkg
Part Number: PSS838528
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 125 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838529 - Spherisorb ODS2 Cartridge, 80Å, 5 µm, 3 mm X 125 mm, 1/pkg

Part Number: PSS838529

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS838529 - Spherisorb ODS2 Cartridge, 80Å, 5 µm, 3 mm X 125 mm, 1/pkg
Part Number: PSS838529
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS2
Chemistry C18
Endcapped No
Format Cartridge
ID 3 mm
Length (mm) 125 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS838533 - Spherisorb C8 Cartridge, 80Å, 5 µm, 3 mm X 125 mm, 1/pkg

Part Number: PSS838533

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS838533 - Spherisorb C8 Cartridge, 80Å, 5 µm, 3 mm X 125 mm, 1/pkg
Part Number: PSS838533
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 125 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

PSS839451 - Spherisorb Silica Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839451

The Spherisorb silica chemistry is general purpose unbonded silica substrate designed for normal phase applications.

PSS839451 - Spherisorb Silica Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839451
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L3
Units in Package 3/pkg
pH Range 2 - 8

info

PSS839458 - Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839458

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS839458 - Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839458
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

PSS839470 - Spherisorb ODSB Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839470

Spherisorb ODSB columns are general purpose, silica-based, reversed-phase C18 columns. The ODSB packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS839470 - Spherisorb ODSB Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839470
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODSB
Chemistry C18
Endcapped Yes
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

PSS839472 - Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839472

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS839472 - Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839472
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

PSS839473 - Spherisorb C8 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839473

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS839473 - Spherisorb C8 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839473
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 3/pkg
pH Range 2 - 8

info

PSS839474 - Spherisorb C6 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg

Part Number: PSS839474

Spherisorb C6 columns are general purpose, silica-based reversed-phase columns that contain a linear-hexyl ligand. These USP L15 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS839474 - Spherisorb C6 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pkg
Part Number: PSS839474
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.7
Chemistry C6
Endcapped Yes
Format Guard Cartridge
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L15
Units in Package 3/pkg
pH Range 2 - 8