Product Listing:  186005652 - Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 75 mm, 1/pkg   to   186005732 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Sorted by Title
  Product    
info

186005652 - Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186005652

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186005652 - Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186005652
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186005653 - Atlantis T3 Column, 100Å, 3 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186005653

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186005653 - Atlantis T3 Column, 100Å, 3 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186005653
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186005657 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pkg

Part Number: 186005657

ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.

186005657 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pkg
Part Number: 186005657
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186005658 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 75 mm, 1/pkg

Part Number: 186005658

ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.

186005658 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 75 mm, 1/pkg
Part Number: 186005658
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Chemistry Amide
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186005660CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE/silicone Septum , 2 mL Volume, 100/pkg

Part Number: 186005660CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005660CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE/silicone Septum , 2 mL Volume, 100/pkg
Part Number: 186005660CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 2 mL

info

186005664CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and PTFE/silicone Septum , 1.5 mL Volume, 100/pkg

Part Number: 186005664CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005664CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and PTFE/silicone Septum , 1.5 mL Volume, 100/pkg
Part Number: 186005664CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Amber Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 1.5 mL

info

186005666CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186005666CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005666CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186005666CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186005667CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE/silicone Septum , 2 mL Volume, 100/pkg

Part Number: 186005667CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005667CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE/silicone Septum , 2 mL Volume, 100/pkg
Part Number: 186005667CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Amber Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 2 mL

info

186005668CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and PTFE/silicone Septum , 1.5 mL Volume, 100/pkg

Part Number: 186005668CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005668CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and PTFE/silicone Septum , 1.5 mL Volume, 100/pkg
Part Number: 186005668CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 1.5 mL

info

186005670CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1.5 mL Volume, 100/pkg

Part Number: 186005670CV

TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.

186005670CV - TruView LCMS Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1.5 mL Volume, 100/pkg
Part Number: 186005670CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified TruView LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Amber Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1.5 mL

info

186005671 - Oasis WCX 30µm OSM Cartridges, 1x10mm, 96/pk

Part Number: 186005671

Waters Oasis WCX Online Solid-Phase Extraction (SPE) Cartridges are designed for use on the ACQUITY UPLC Online SPE Manager (OSM), a component of the ACQUITY UPLC Automated SPE System. Oasis WCX sorbent is a patented polymeric sorbent that uses reversed-phase and weak cation exchange retention mechanisms for highly selective sample preparation of strong basic compounds. Oasis WCX Online SPE Cartridges can withstand pressures up to 15,000 psi (1,000 bar) during the SPE elution stage and are compatible with solvents in the pH 0-14 range. Each tray contains 96 cartridges. The narrow bore PEEK (polyether ether ketone) cartridges are available in a 1 x 10 mm format containing 4 mg of sorbent. The ACQUITY UPLC Online SPE Manager allows for full automation of online SPE and permits the use of up to 23 different solvents for the solvation, equilibration and washing stages of the SPE process. Oasis WCX OSM Cartridges are designed for single use only.

186005671 - Oasis WCX 30µm OSM Cartridges, 1x10mm, 96/pk
Part Number: 186005671
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry WCX
Ion Exch. Capacity 0.75 meq/gram
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Units In Package 96/pkg
pH Range 0 - 14 pH

info

186005672 - XBridge C18 10µm OSM Cartridges, 1x10mm, 96/pk

Part Number: 186005672

Waters XBridge C18 OSM Solid-Phase Extraction (SPE) Cartridges are designed for use on the ACQUITY UPLC Online SPE Manager (OSM), a component of the ACQUITY UPLC Automated SPE System. The XBridge™ C18 sorbent uses Waters proprietary Ethylene Bridged Hybrid (BEH) Technology to provide particles with high mechanical strength, excellent peak shape, high efficiency, and excellent pH stability for acidic and basic extraction solvents. These online SPE Cartridges can withstand pressures up to 15,000 psi (1,000 bar) during the SPE elution stage and are compatible with solvents in the pH 1-12 range. Each tray contains 96 cartridges. The narrow bore PEEK (polyether ether ketone) cartridges are available in a 1 x 10 mm format containing 4 mg of sorbent. The ACQUITY UPLC Online SPE Manager allows for full automation of online SPE and permits the use of up to 23 different solvents for the solvation, equilibration and washing stages of the SPE process. XBridge C18 OSM Cartridges are designed for single use only.

186005672 - XBridge C18 10µm OSM Cartridges, 1x10mm, 96/pk
Part Number: 186005672
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Mode Reversed-phase
Units In Package 96/pkg

info

186005673 - XBridge C8 10µm OSM Cartridges, 1x10mm, 96/pk

Part Number: 186005673

Waters XBridge C8 OSM Solid-Phase Extraction (SPE) Cartridges are designed for use only on the ACQUITY UPLC Online SPE Manager (OSM), a component of the ACQUITY UPLC Automated SPE System. The XBridge™ C8 sorbent uses Waters proprietary Ethylene Bridged Hybrid (BEH) Technology to provide particles with high mechanical strength, excellent peak shape, high efficiency, and excellent pH stability for acidic and basic extraction solvents. The C8 sorbent is less retentive than XBridge C18 sorbent. The XBridge C8 Online SPE Cartridges can withstand pressures up to 15,000 psi (1,000 bar) during the SPE elution stage and are compatible with solvents in the pH 1-12 range. Each tray contains 96 cartridges.These online SPE Cartridges can withstand pressures up to 15,000 psi (1,000 bar) during the SPE elution stage and are compatible with solvents in the pH 1-12 range. Each tray contains 96 cartridges. The narrow bore PEEK (polyether ether ketone) cartridges are available in a 1 x 10 mm format containing 4 mg of sorbent. The ACQUITY UPLC Online SPE Manager allows for full automation of online SPE and permits the use of up to 23 different solvents for the solvation, equilibration and washing stages of the SPE process. XBridge C8 OSM Cartridges are designed for single use only.

186005673 - XBridge C8 10µm OSM Cartridges, 1x10mm, 96/pk
Part Number: 186005673
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C8
Mode Reversed-phase
Units In Package 96/pkg

info

186005689 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186005689

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005689 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186005689
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005690 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186005690

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005690 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186005690
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005695 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005695

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005695 - Viridis CSH Fluoro-Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005695
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005702 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186005702

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005702 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186005702
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186005704

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186005704
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005705

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005705
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005706

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005706
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186005708

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186005708
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005709

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005709
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005719 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186005719

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005719 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186005719
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005720 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186005720

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005720 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186005720
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005721 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186005721

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005721 - Viridis BEH Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186005721
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005724 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186005724

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005724 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186005724
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005725 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186005725

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005725 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186005725
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005726 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005726

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005726 - Viridis BEH Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005726
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005731 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg

Part Number: 186005731

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005731 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg
Part Number: 186005731
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186005732 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Part Number: 186005732

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005732 - Viridis BEH OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg
Part Number: 186005732
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg