186004629 - ACQUITY UPLC VanGuard Pre-column Reversed-Phase 1.7 µm Spherical Hybrid, 2.1 mm x 5 mm, 3/pkg, BEH



186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering contains Waters patented BEH Technology C18, 300A pore, 1.7um particles based and each batch is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.

Product Number: 186004629

Availability:       ----
List Price: Loading price...


% Carbon Load 12
Application Peptide
Brand ACQUITY UPLC
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 90
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

Related Products Qty
Hover for more details on 186005666CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

186005666CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186005666CV
TruView LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested for cleanliness by mass spectrometers and for low analyte adsorption by ACQUITY/MS/MS.
186005666CV - TruView LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Product Number: 186005666CV

Hover for more details on 186005837 - 96-well Sample Collection Plate, 700uL Round well 25/pkg

186005837 - 96-well Sample Collection Plate, 700uL Round well 25/pkg

Part Number: 186005837
Polypropylene 96-well plate with a well designed to have the lowest residual sample volume for ACQUITY UPLC Sample Managers. Meets all ANSI/SBS standards for robotic compatability.
186005837 - 96-well Sample Collection Plate, 700uL Round well 25/pkg
Product Number: 186005837

Hover for more details on 186006360 - Neutrals QC Reference Material

186006360 - Neutrals QC Reference Material

Part Number: 186006360
The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. Kit Contents: One ampule with 10 ?L/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL
186006360 - Neutrals QC Reference Material
Product Number: 186006360

Hover for more details on 186006363 - Reversed-Phase QC Reference Material

186006363 - Reversed-Phase QC Reference Material

Part Number: 186006363
The Quality Control Reference Materials portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientist. The Reversed-Phase QC Reference Material is a significantly complex reference material mixture in that it contains compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. It can be used with a variety of column chemistries and dimensions, and system hardware. The Reversed-Phase QC Reference Material contains 7 compounds including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm the benchmark performance of your analytical HPLC or UPLC system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic and basic compounds. These compounds were vigorously tested and evaluated and chosen because they provide the following advantages: – Excellent benchmark – Good peak shape on UV – Acceptable for use on a variety of column
186006363 - Reversed-Phase QC Reference Material
Product Number: 186006363

Hover for more details on 186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004629
VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering contains Waters patented BEH Technology C18, 300A pore, 1.7um particles based and each batch is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.
186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186004629

Hover for more details on 186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006939
Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186006939

Hover for more details on 186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004623
Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186004623

Hover for more details on 176003699 - ACQUITY UPLC Glycoprotein BEH Amide VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg with Glycoprotein Performance Test Standard

176003699 - ACQUITY UPLC Glycoprotein BEH Amide VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg with Glycoprotein Performance Test Standard

Part Number: 176003699
Waters Glycoprotein BEH Amide 300A, 1.7um columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300A 1.7um material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 86008010 that includes a mixture of Ribonuclease A as well as Ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300A, 1.7um column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
176003699 - ACQUITY UPLC Glycoprotein BEH Amide VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg with Glycoprotein Performance Test Standard
Product Number: 176003699

Hover for more details on 186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004739
The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186004739

Hover for more details on 186004897 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg

186004897 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186004897
This kit consists of three ACQUITY UPLC BEH300 C18 PST columns packed with three different batches of sorbent.
186004897 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 100 mm, 3/pkg
Product Number: 186004897

Hover for more details on 186006517 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

186006517 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006517
This kit consists of three ACQUITY UPLC BEH300 C18 PST columns packed with three different batches of sorbent.
186006517 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Product Number: 186006517

Hover for more details on 186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003975
As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186003975

Waters Online ToolBox

Product Selection made easy
View Now

Academic Preferred Pricing on Consumables Working in Academia? Receive Waters Preferred Pricing!

Receive a 20% discount on your consumable products order! From LC columns to sample prep, vials, filters, standards & reagents, and workflow analytical kits like GlycoWorks & ProteinWorks. Discount will be applied to cart.
Order today!