186003687 - ACQUITY UPLC Column Reversed-Phase 1.7 µm Spherical Hybrid, 2.1 mm x 150 mm, 1/pkg, BEH



186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

Product Number: 186003687

Availability:       ----
List Price: Loading price...


Application Peptide
Brand ACQUITY UPLC
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

Related Products Qty
Hover for more details on 205000343 - ACQUITY UPLC Col. In-Line Filter Kit

205000343 - ACQUITY UPLC Col. In-Line Filter Kit

Part Number: 205000343
Waters recommends you filter buffers and samples using a 0.2µm filter prior to using ACQUITY UPLC™ BEH columns. Filtration protects the columns and instrument components from a build-up of particulate matter, improving column lifetime and minimizing system downtime. The ACQUITY UPLC™ column In-line filter kit comes complete with the holder and five 0.2µm stainless steel replacement filters. You can order a a package of five replacement filters using Part Number 700002775 which will work with the in-line filter kit.
205000343 - ACQUITY UPLC Col. In-Line Filter Kit
Product Number: 205000343

Hover for more details on 186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004629
VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering contains Waters patented BEH Technology C18, 300A pore, 1.7um particles based and each batch is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.
186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Product Number: 186004629

Hover for more details on 186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003687
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Product Number: 186003687

Hover for more details on 186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003685
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Product Number: 186003685

Hover for more details on 186003686 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

186003686 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003686
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003686 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Product Number: 186003686

Hover for more details on 186005592 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 50 mm, 1/pkg

186005592 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 50 mm, 1/pkg

Part Number: 186005592
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186005592 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 50 mm, 1/pkg
Product Number: 186005592

Hover for more details on 186005594 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 150 mm, 1/pkg

186005594 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 150 mm, 1/pkg

Part Number: 186005594
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186005594 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 150 mm, 1/pkg
Product Number: 186005594

Hover for more details on 186005593 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 100 mm, 1/pkg

186005593 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 100 mm, 1/pkg

Part Number: 186005593
The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186005593 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 100 mm, 1/pkg
Product Number: 186005593

Hover for more details on 186003554 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

186003554 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003554
The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003554 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Product Number: 186003554

Hover for more details on 186003555 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

186003555 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003555
The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003555 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Product Number: 186003555

Hover for more details on 186003556 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

186003556 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003556
The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186003556 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Product Number: 186003556

Hover for more details on 186005792 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 300 mm, 1/pkg

186005792 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 300 mm, 1/pkg

Part Number: 186005792
The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
186005792 - ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 300 mm, 1/pkg
Product Number: 186005792

Waters Online ToolBox

Product Selection made easy
View Now

Academic Preferred Pricing on Consumables Working in Academia? Receive Waters Preferred Pricing!

Receive a 20% discount on your consumable products order! From LC columns to sample prep, vials, filters, standards & reagents, and workflow analytical kits like GlycoWorks & ProteinWorks. Discount will be applied to cart.
Order today!