186000254 - Oasis MCX 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk



186000254 - Oasis MCX 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk The 3 cc Oasis MCX cartridges contain the Oasis MCX, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. Since the Oasis MCX sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

Product Number: 186000254

Availability:       ----
List Price: Loading price...


Barrel Size 3 cc
Brand Oasis
Chemistry MCX
Format/Type Vac Cartridge
Ion Exch. Capacity 1 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

Related Products Qty
Hover for more details on 725000417 - Vacuum Pump 110/115 V 60H

725000417 - Vacuum Pump 110/115 V 60H

Part Number: 725000417
This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L
725000417 - Vacuum Pump 110/115 V 60H
Product Number: 725000417

Hover for more details on WAT200606 - Extraction Manifold,20 pos, 13x75 mm tubes WAT200606 - Extraction Manifold,20 pos, 13x75 mm tubes
Product Number: WAT200606

Hover for more details on 186006103 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

186006103 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006103
XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
186006103 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Product Number: 186006103

Hover for more details on 186006151 - XSelect HSS T3 XP Column, 100Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

186006151 - XSelect HSS T3 XP Column, 100Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006151
The XSelect HSS T3 is a low-coverage C18 phase compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The XSelect HSS T3 columns exhibit ultra-low MS bleed and are fully scalable and transferable to UPLC separations. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
186006151 - XSelect HSS T3 XP Column, 100Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Product Number: 186006151

Hover for more details on 186006198 - XBridge BEH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

186006198 - XBridge BEH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186006198
This method validation kit consists of three batches of XBridge BEH C18 columns packed with three different batches of sorbent
186006198 - XBridge BEH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg
Product Number: 186006198

Hover for more details on 186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001830BA
The patented 96-well Oasis MCX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis MCX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis MCX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
186001830BA - Oasis MCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186001830BA

Hover for more details on 186001256 - Oasis MAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186001256 - Oasis MAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001256
The Oasis MAX 96-well plate contains the Oasis MAX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting acidic compounds with anion-exchange groups. The unique balance of hydrophobicity and water-wettability of the Oasis MAX sorbent means you will never have to worry about poor results if individual wells of the 96-well plate dry out during the critical steps prior to sample loading. The Oasis MAX 96-well plate is designed to be used on many manifold configurations and most robotic liquid handling systems.
186001256 - Oasis MAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186001256

Hover for more details on 186003915 - Oasis WAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186003915 - Oasis WAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186003915
The Oasis WAX 96-well plate contains the Oasis WAX sorbent, which is a polymeric reversed-phase, weak anion exchange mixed-mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong acidic compounds. The unique balance of hydrophobicity and water-wettability of the Oasis WAX sorbent means you will never have to worry about poor results if individual wells of the 96-well plate dry out during the critical steps prior to sample loading. The Oasis WAX 96-well plate is designed to be used on many manifold configurations and most robotic liquid handling systems.
186003915 - Oasis WAX 96-well Plate, 60 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186003915

Hover for more details on 186001828BA - Oasis HLB 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186001828BA - Oasis HLB 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001828BA
The patented 96-well Oasis HLB µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent for extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis HLB µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
186001828BA - Oasis HLB 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186001828BA

Hover for more details on 186001829 - Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186001829 - Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186001829
The patented 96-well Oasis MAX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis MAX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting acidic compounds with anion-exchange groups. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis MAX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
186001829 - Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186001829

Hover for more details on 186002499 - Oasis WCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186002499 - Oasis WCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186002499
The patented 96-well Oasis WCX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis WCX sorbent, which is a polymeric reversed-phase, weak ion exchange mixed-mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong basic compounds and quaternary amines. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible result?s without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis WCX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
186002499 - Oasis WCX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186002499

Hover for more details on 186002500 - Oasis WAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

186002500 - Oasis WAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186002500
The patented 96-well Oasis WAX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 ?L to 375 ?L. Each well of the µElution plate contains 2 mg of the Oasis WAX sorbent, which is a polymeric reversed-phase, weak anion exchange mixed-mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong acidic compounds. The innovative features of Oasis ?Elution plate enabled elution in only 25 ?L, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis WAX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
186002500 - Oasis WAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Product Number: 186002500

Contact Waters

Local Offices

Related Categories

UHPLC Columns (CORTECS shown) SPECIAL SAVINGS ON UHPLC COLUMNS!

Receive 20% off all UHPLC CORTECS, XBridge or XSelect 2.5 or 2.7um columns now through December 31st, 2017! Apply offer code UHPLC at checkout to receive your discount.
View our UHPLC Columns

Waters Online ToolBox

Product Selection made easy
View Now

Academic Preferred Pricing on Consumables Working in Academia? Receive Waters Preferred Pricing!

Receive a 20% discount on your consumable products order! From LC columns to sample prep, vials, filters, standards & reagents, and workflow analytical kits like GlycoWorks & ProteinWorks. Discount will be applied to cart.
Order today!